• 제목/요약/키워드: Fault detecting scheme

검색결과 29건 처리시간 0.031초

유압실린더 내부 누유 검출을 위한 H 관측기 설계 (H Observer Design for Detecting Internal Oil Leakage in a Hydraulic Cylinder)

  • 지성철;강형주;이문직;이계홍
    • 제어로봇시스템학회논문지
    • /
    • 제22권2호
    • /
    • pp.117-125
    • /
    • 2016
  • This paper presents the internal oil leakage detection problem for a hydraulic double-rod cylinder. We represent the dynamics of the hydraulic cylinder as a convex combination of linear equations. To detect oil leakage, we propose a model-based fault detection observer design scheme. The observer is designed to be robust against disturbance. Sufficient design conditions are derived in the form of linear matrix inequalities. A numerical example is provided to verify the proposed techniques.

IEC 61850기반 변전소 자동화 시스템에서 IED의 결함 극복 방법 (Fault Tolerant of IED in IEC61850 based Substation Automation System)

  • 이동욱;진용우;이덕수;임성일;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes new methods which are used for trouble detecting and tolerance of IED in IEC61850 based Substation Automation System. There are three point devices for construction of this system: Trouble Detection IED, Backup IED and Engineering Unit. Trouble Detection IED tests trouble of Bay IED and sends the result to Engineering Unit. And then Engineering Unit is able to control the system. When fault occurs in Bay IED, Backup IED will be substitute the troubled Bay IED. If this proposed scheme can be used in this system, the reliability of the Power System would be greatly improved.

  • PDF

Design of SPS in the Korean Power System Against Faults on 765 KV Lines

  • Park Jong-Young;Park Jong-Keun;Jang Byung-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.132-137
    • /
    • 2005
  • In Korea, the protection systems against the instability of the nation's power system are insufficient in contrast with many other countries. In addition, there have just been studies carried out on detecting power system instability, while only a few studies pertaining to protection plans against instability exist. This paper focuses on systems to protect against the instability phenomena in the Korean power system. In this paper, we survey possible contingencies in the Korean power system and suggest outline and specs of the SPS (System Protection Scheme) against faults on the 765 kV line, based on simulations. It is concluded that event-based SPS for transient stability is appropriate for the Korean power system. In the simulations, the most severe contingency on the Korean power system is the fault on 765 kV transmission lines. If one of these lines is tripped by a fault, synchronism may be lost on the power plants near this line because of heavy power flow carried by them. In addition, undervoltage in the Metropolitan region is a serious problem in this case since this region receives about half its total power flow through these lines. In order to prevent a synchronism loss, some power plants have to be rejected according to the situations in the simulations.

편로드 유압실린더 내부 누유 검출을 위한 T—S 퍼지 모델 기반 샘플치 관측기 설계: LMI 접근법 (T—S Fuzzy Model-based Sampled-data Observer Design for Detecting Internal Oil Leakage in Single-rod Hydraulic Cylinder: LMI Approach)

  • 지성철;김효곤;박정우;이문직;강형주;이계홍
    • 한국해양공학회지
    • /
    • 제30권5호
    • /
    • pp.405-414
    • /
    • 2016
  • This paper presents an internal oil leakage detection problem for a hydraulic single-rod cylinder. We derive the dynamics of the hydraulic cylinder as a state space model, and then design a T—S fuzzy model-based fault detection observer. We adopt an H observer design scheme so that the observer is robust against disturbance and relatively sensitive to the leakage fault. Sufficient design conditions are derived in the form of linear matrix inequalities. A numerical example is provided to verify the proposed techniques.

BCH 코드를 이용한 함정 분산 제어망을 위한 실시간 고장 노드 탐지 기법 (Real-time Faulty Node Detection scheme in Naval Distributed Control Networks using BCH codes)

  • 노동희;김동성
    • 전자공학회논문지
    • /
    • 제51권5호
    • /
    • pp.20-28
    • /
    • 2014
  • 본 논문에서는 분산 제어망에서 통신 오류가 발생한 노드를 실시간으로 탐지할 수 있는 기법을 제안한다. 기존의 분산 제어망은 노드 내 오류가 발생하는 지점을 탐지하기 위해, 노드 간 의존성의 영향을 고려해야 하며 이는 전체적인 분산 제어망의 성능 저하의 원인이 될 수 있다. 이를 해결하기 위하여, 본 논문에서 제안된 기법은 각 노드의 손상으로 인해 발생되는 고장노드들을 빠른 시간 내에 탐지하기 위해 단일 Bose-Chaudhuri-Hocquenghem (BCH) 비트를 Cyclic Redundancy Check (CRC) 코드에 삽입하여 기존의 CRC 코드 내 비트와 대체하는 방식을 택한다. 고장 노드 판정의 탐지 정확성을 높이기 위해 고장 가중치 계수를 통한 고장 판단 기법을 제안한다. 제안된 기법의 효용성을 증명하기 위해 MATLAB을 이용하여 모의실험 환경을 구축하고, 제안된 기법의 성능을 분석하였다. 이를 통하여, BCH 코드 내 비트 간 분배를 통해 수정되는 정도에 관계없이 CRC 코드의 성능이 우수하게 보존됨을 알 수 있었으며, 기존의 CRC 코드 기법보다 빠른 시간 내에 손상된 노드를 탐지할 수 있음을 보였다.

절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석 (Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures)

  • 김창종;이흥재;신정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF

발전기 계자보호를 위한 계자상실 알고리즘에 관한 연구 (A Study on Loss of Excitation Algorithm for Generator Field Protection)

  • 박유영;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.368-372
    • /
    • 2014
  • The most widely used scheme for detecting loss of excitation on generator is used to sense apparent impedance from generator terminals. This paper presents loss of excitation algorithm using DFT filter based negative offset mho elements for generator field protection. It's algorithm includes two negative mho characteristics looking in the generator. The generator control system was modeled by PSCAD/EMTDC software, and then the proposed algorithm was tested by the collecting relaying signals from selected the generator model. From simulation results, the loss of excitation algorithm can be used to field protection for generator.

A Smooth LVRT Control Strategy for Single-Phase Two-Stage Grid-Connected PV Inverters

  • Xiao, Furong;Dong, Lei;Khahro, Shahnawaz Farhan;Huang, Xiaojiang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.806-818
    • /
    • 2015
  • Based on the inherent relationship between dc-bus voltage and grid feeding active power, two dc-bus voltage regulators with different references are adopted for a grid-connected PV inverter operating in both normal grid voltage mode and low grid voltage mode. In the proposed scheme, an additional dc-bus voltage regulator paralleled with maximum power point tracking controller is used to guarantee the reliability of the low voltage ride-through (LVRT) of the inverter. Unlike conventional LVRT strategies, the proposed strategy does not require detecting grid voltage sag fault in terms of realizing LVRT. Moreover, the developed method does not have switching operations. The proposed technique can also enhance the stability of a power system in case of varying environmental conditions during a low grid voltage period. The operation principle of the presented LVRT control strategy is presented in detail, together with the design guidelines for the key parameters. Finally, a 3 kW prototype is built to validate the feasibility of the proposed LVRT strategy.

배치 공정의 온라인 모니터링을 위한 다변량 관리도 (Multivariate SPC Charts for On-line Monitoring the Batch Processes)

  • 이배진;강창욱
    • 한국산업경영시스템학회:학술대회논문집
    • /
    • 한국산업경영시스템학회 2002년도 춘계학술대회
    • /
    • pp.387-396
    • /
    • 2002
  • Batch processes are a significant class of processes in the process industry and play an important role in the production of high quality speciality materials. Examples include the production of semiconductors, chemicals, pharmaceuticals, and biochemicals. With on-line sensors connected to most batch processes, massive amounts of data are being collected routinely during the batch on easily measured process variables such as temperatures, pressures, and flowrates. In this paper, multivariate SPC charts for on-line monitoring of the progress of new batches are developed which utilize the information in the on-line measurements in real-time. We propose the formation of statistical model which describes the normal operation of a batch at each time interval during the batch operation. An on-line monitoring scheme based on the proposed method can handle both cross-correlation among process variables at any one time and auto-correlation over time. And the control limits for the monitoring charts are established from sound statistical framework unlike previous researches which use the external reference distribution. The proposed charts perform real-time, on-line monitoring to ensure that the batch is progressing in a manner that will lead to a high-quality product or to detect and indicate faults that can be corrected prior to completion of the batch. This approach is capable of tracking the progress of new batch runs, identifying the time periods in which the fault occurred and detecting underlying cause.

  • PDF