• Title/Summary/Keyword: Fault current limiter

Search Result 563, Processing Time 0.026 seconds

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

The Design of a Inductive Superconducting Fault Current Limiter (유도형 초전도 사고전류제한기의 설계)

  • Bae, Joon-Han;Lee, Sang-Jin;Oh, Yun-Sang;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.119-121
    • /
    • 1995
  • This paper is a study on inductive superconducting fault current limiter design.. We have created simulation for an imaginery power system with inductive superconducting fault current limiter. Then input variables for characteristic analysis and actual manufacturing, and output variables for design results was assigned. Using the results from these variables, the design criterion was determined which was fed into concept design arising from characteristic analysis to determine the inductance of limiting coil and normal state resistance value of triggering coil. These result was put back into design details to finally give out the design result for inductive superconducting fault current limiter.

  • PDF

Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line (전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.148-152
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.

Analysis on the Protective Coordination in Power Distribution System with Superconducting Fault Current Limiter (배전계통에 초전도 전류 제한기 적용시 보호협조 분석)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.755-760
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. Therefore, to introduce SFCL into power distribution system, the analysis on protection in power distribution system with SFCL is essential. In this paper, the problems of the protective coordination in power distribution system with SFCL were described.

Switching Characteristics of a Superconducting Current Limiter (초전도전류제한기(超傳導電流制限器)의 스위칭 특성(特性))

  • Cha, Guee-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.36-40
    • /
    • 1990
  • According to the rapid growth of transmission power, fault current level approaches to the maximum capacity of circuit breaker. This paper has been proposed a superconducting current limiter (SCL) to reduce the fault current to appropriate level. Superconductor for SCL has been examined and design criterion of each triggering method has been shown. Superconducting current limiter was fabricated using thin film and switching characteristics were shown, where thermal and current triggering were adopted.

  • PDF

Analysis on Fault Current Limiting and Bus-Voltage Sag Suppressing Characteristics of a Transformer Type Superconducting Fault Current Limiter (변압기형 초전도 한류기의 고장전류 제한 및 모선전압강하 억제특성 분석)

  • Park, Jin-Seol;Kang, Dae-Seung;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.113-117
    • /
    • 2011
  • As one of the countermeasures to solve the increase of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed together with the development of a various types of SFCL, which has accelerated the researches to apply a SFCL into a power system. Among the developed SFCLs, the transformer type SFCL is expected to be available for adjusting the voltage and the current ratings of the SFCL. In this paper, the fault current limiting and the bus line‘s voltage sag suppressing effect by the transformer type SFCL were investigated and the case without the transformer type SFCL was compared as well. Through the analysis on the results of the short-circuit tests, the fault current limiting and the bus-line voltage suppressing characteristics of the transformer type SFCL could be confirmed to be effectively performed.

Effect of inserting resistance's magnitude on OCR trip time in a short-circuit of distribution system (배전계통 사고시 투입저항 크기가 OCR트립 시간에 미치는 영향)

  • Ahn, Jae-Min;Kim, Jae-Chul;Lim, Sung-Hun;Kim, Jin-Seok;Moon, Jong-Fil
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.154-155
    • /
    • 2007
  • Increase of fault current due to larger power demand has increased the possibility of the breakdown of the power system. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. In this paper, the fault current limiter, which consists of a ideal switch as a trigger part and the limiter as the limiting part, has been applied into the distribution system. From the analysis for the fault current limiting operation of SFCL, the inserting resistance's magnitude has been confirmed to affect OCR trip time in a short-circuit of distribution system.

  • PDF

The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting (고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석)

  • Song, Jae-Joo;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

Fault Current Limiting Characteristic of Flux-Lock Type HTSC Fault Current Limiter (자속구속형 고온초전도 전류제한기 사고전류제한 특성)

  • Lim, Sung-Hun;Choi, Myung-Ho;Park, Bok-Kee;Song, Jee-Joo;Park, Dae-Hee;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.105-108
    • /
    • 2002
  • In this paper, we investigated the fault current limiting characteristic of flux-lock type High-Tc superconducting fault current limiter(HTSC-FCL), which is comprised of a flux-lock reactor and an external magnetic field coil covering the HTSC element In this HTSC-FCL, the initial limiting current level can be controlled by adjusting the inductance of the each coil. Furthermore, the fault current limiting characteristics of HTSC-FCL can be improved by applying 'the external magnetic field into the HTSC element We performed the computer simulation by numerical analysis about the flux-lock type HTSC-FCL and compared the results of experiment with simulation ones. We can obtain the same results from both the computer simulation and the experiment except for the time immediately after fault occurs.

  • PDF