• Title/Summary/Keyword: Fault Analysis

Search Result 2,764, Processing Time 0.026 seconds

An Approach to Software Analysis and Design based on Distributed Components (분산 컴포넌트 기반의 소프트웨어 분석 및 설계 방법)

  • Choi, You-Hee;Yeom, Keun-Hyuk
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.12
    • /
    • pp.896-909
    • /
    • 2001
  • Recently, above 50 percentages of software are being developed based on distributed application platforms. And recent technologies such as EJB(Enterprise Java Beans)[1]COM(Component Object Model)[2] CORBA(Common Object Request Broker Architecture)[3] have been advanced for distributed component-based software development . Therefore a systematic development process is necessary to develop component based applications using distributed application platforms. However, most of component-base software development processes do not define concrete flows between tasks and relationships among artifacts of each task Also, distribution issues are not considered explicitly in most of component-based software development In this paper, we present an approach to analyze and design software based on distributed components. In this approach, we propose systematic guidelines for developing a software based on Unified process and the relationships among artifacts which are produced, Also we explicitly consider the distribution issues such as performance, fault tolerance, security, distributed transaction of CORBA environments.

  • PDF

A Study on Stirling Cryocooler for Precooling Hydrogen Liquefier (수소액화 예냉용 소형 스털링 극저온 냉동기 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.651-659
    • /
    • 2016
  • Korea Institute of Machinery & Materials (KIMM) has developed a high efficient Stirling cryocooler with moving magnet linear compressor for precooling hydrogen liquefier and cooling high temperature superconductor (HTS) devices, such as superconductor cable and superconductor fault current limiters. Hydrogen liquefier and HTS electric devices require cryocooler with cooling capacity of hundred watts to kilowatts at 77 K. The compressor in the Stirling cryocooler uses opposed moving magnet linear motors to drive opposed pistons. High efficient Stirling cryocooler is designed by SAGE-software, manufactured and tested systematically. A cooling capacity of 1 kW at 77 K with an electric input power of 9.6 kW has been analyzed. But prototype test results of the Stirling cryocooler have the cooling capacity of 0.65 kW at 76.8 K with an electric input power of 8.1 kW. And then, 21.5% Carnot COP (Coefficient of performance) of the prototype Stirling cryocooler is achieved. The comparison analysis between SAGE-model and experimental results has shown the direction for further design optimization of the Stirling cryocooler.

Analysis on Quench Recovery Dependence of A Flux-Lock Type SFCL According to the Winding Directions (결선방향에 따른 자속구속형 전류제한기의 퀜치 회복 의존도 해석)

  • Jung, Su-Bok;Cho, Yong-Sun;Choi, Myoung-Ho;Choi, Hyo-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • We investigated the current limiting and the recovery characteristics of a flux-lock type superconducting fault current limiter(SFCL) according to the winding directions. The flux-lock type SFCL consists of two coils. The primary coil was wound in parallel to the secondary coil through an Iron core, and the secondary coil was connected with the superconducting element in series. We have changed the winding direction of coils to compare the resistive type SFCL with the flux-lock type SFCL. The current limiting and the recovery characteristics were dependent on the winding direction. The quenching time in the additive polarity winding was faster than that of the subtractive polarity winding or the resistivity type. A consumed energy in a superconducting element was represented as $W= VIt=I^2Rt$. We found that there was a difference in the consumed energies in accordance with winding types because of differences in voltages imposed on a superconducting element in accordance with a winding direction.

Analysis of abnormal traffic controller deployed in Internet access point (인터넷 액세스점에서의 이상 트래픽 제어기 성능분석)

  • Kim Kwangsik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1C
    • /
    • pp.107-115
    • /
    • 2005
  • ATC (Abnormal traffic controller) is presented as next generation security technology to securely support reliable Internet service and to guarantee network survivability, which is deployed in Internet access point. The key concept of the ATC is abnormal traffic monitoring and traffic control technology. When fault factors exist continuously and/or are repeated, abnormal traffic control guarantees service completeness as much as possible. The ATC with control policy on abnormal traffic is superior to the ATC with blocking policy as well as conventional network node, when the ratio of effective traffic to abnormal traffic is higher than $30{\%}.$ When traffic intended unknown attack occurs, network IDS is high false positive probability and so is limited to apply. In this environment, the ATC can be a key player to help the network node such as router to control abnormal traffic.

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

Study on the Recovery and Recrystalligation of Cold-lolled Zr-based Alloys by Thermoelectric Power Measurement During Isothermal Annealing (TEP 분석을 이용한 냉간가공된 Zr-based 합금의 등온열처리에 따른 회복 및 재결정 거동에 관한 연구)

  • O, Yeong-Min;Jeong, Heung-Sik;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.483-491
    • /
    • 2001
  • The recovery and recrystallization behavior of cold-rolled Zr-based alloys during isothermal annealing at temperatures from $575^{\circ}C$ to $650^{\circ}C$ was studied by thermoelectric power and Vickers microhardness measurement. The recovery and recrystallization resulted in the increase of TEP doe to the extinction of lattice defect, vacancy, dislocation and stacking fault during isothermal annealing after cold- rolling. The completion of recrystallization could be determined much clearly by TEP behavior than by microhardness change in Zr-based alloys. Especially, the recovery and recrystallization were classified separately by TEP behavior in Zr-0.4Nb-xSn alloys. From the analysis of TEP behavior and microhardness, the addition of Sn caused to form the interaction between stain field and dislocation, which resulted in the delay of recovery in Zr-based alloys. The precipitation due the addition of Nb suppressed the grain growth after recrystallization effectively in Zr-based alloys.

  • PDF

A Study on the Learning Curve and VOC Factors Affecting of Telecommunication Services (통신 상품별 VOC 영향 요인과 학습곡선에 관한 연구)

  • Jung, So-Ki;Cha, Kyoung Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.8
    • /
    • pp.518-527
    • /
    • 2014
  • This study is to estimate the learning curve based on the consequences of reduced voice of customer from each telecommunication service products. We used Exponential Decay Model, which is the most popular among the learning curve models. We attempted to add how VOC changes in accordance with seasonal factors, human resource input, application of software, and the investment. The results of the empirical analysis of each service product as follows: First, as learning curve, customer complaints decreased. Second, human resource input, Network fault make increase or decrease customer complaints(VOC). Third, even though increasing the customer's quality of experience, VOC would not decrease due to service paradox.

Development of the High Reliable Safety PLC for the Nuclear Power Plants (고신뢰도 안전등급 제어기기 개발)

  • Son, Kwang-Seop;Kim, Dong-Hoon;Son, Choul-Woong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.109-119
    • /
    • 2013
  • This paper presents the design of the Safety Programmable Logic Controller (SPLC) used in the Nuclear Power Plants, an analysis of a reliability for the SPLC using a markov model. The architecture of the SPLC is designed to have the multiple modular redundancy composed of the Dual Modular Redundancy(DMR) and the Triple Modular Redundancy(TMR). The operating system of the SPLC is designed to have the non-preemptive state based scheduler and the supervisory task managing the sequential scheduling, timing of tasks, diagnostic and security. The data communication of the SPLC is designed to have the deterministic state based protocol, and is designed to satisfy the effective transmission capacity of 20Mbps. Using Markov model, the reliability of SPLC is analyzed, and assessed. To have the reasonable reliability such as the mean time to failure (MTTF) more than 10,000 hours, the failure rate of each SPLC module should be less than $2{\times}10^{-5}$/hour. When the fault coverage factor (FCF) is increased by 0.1, the MTTF is improved by about 4 months, thus to enhance the MTTF effectively, it is needed that the diagnostic ability of each SPLC module should be strengthened. Also as the result of comparison the SPLC and the existing safety grade PLCs, the reliability and MTTF of SPLC is up to 1.6-times and up to 22,000 hours better than the existing PLCs.

Malfunction Measures and Susceptibility test of Elevator Based on EMS(Electromagnetic Susceptibility) Standard (EMS 규정에 따른 승강기 내성시험 및 오동작 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Lee, Joo-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.78-85
    • /
    • 2007
  • The malfunction accidents such as kept within elevator, sudden rise, sudden stop, error of level indication which can bring about uneasiness of elevator passenger and be related with life accident are occurring. However, as there is not field recurrence for this portion and they are accidents that occur and then disappear, it is actually difficult to confirm the reason of accident. Therefore, we made an experiment for tolerance in three models which is being built recently according to EN12016(2004) standard and analyzed the movement characteristics of elevator to study the reason which can bring about confine and malfunction. Furthermore after supplementing measures for malfunction, Finally this paper will be used as reference to suggest methods for malfunction of elevator facility and the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.