• Title/Summary/Keyword: Fatigue-free

Search Result 200, Processing Time 0.027 seconds

New Generation of Lead Free Paste Development

  • Albrecht Hans Juergen;Trodler K. G.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.233-241
    • /
    • 2004
  • A new alloy definition will be presented concerning increasing demands for the board level reliability of miniaturized interconnections. The damage mechanism for LFBGA components on different board finishes is not quite understood. Further demands from mobile phones are the drop test, characterizing interface performance of different package constructions in relation to decreased pad constructions and therefore interfaces. The paper discusses the characterization of interfaces based on SnPb, SnPbXYZ, SnAgCu and SnAgCuInNd ball materials and SnAgCuInNd as solder paste, the stability after accelerated tests and the description of modified interfaces strictly related to the assembly conditions, dissolution behavior of finishes on board side and the influence of intermetallic formation. The type of intermetallic as well as the quantity of intermetallics are observed, primaliry the hardness, E modules describing the ability of strain/stress compensation. First results of board level reliability are presented after TCT-40/+150. Improvement steps from the ball formulation will be discussed in conjunction to the implementation of lead free materials In order to optimize ball materials for area array devices accelareted aging conditions like TCTs were used to analyze the board level reliability of different ball materials for BGA, LFBGA, CSP, Flip Chip. The paper outlines lead-free ball analysis in comparison to conventional solder balls for BGA and chip size packages. The important points of interest are the description of processability related to existing ball attach procedures, requirements of interconnection properties and the knowledge gained the board level reliability. Both are the primary acceptance criteria for implementation. Knowledge about melting characteristic, surface tension depend on temperature and organic vehicles, wetting behavior, electrical conductivity, thermal conductivity, specific heat, mechanical strength, creep and relaxation properties, interactions to preferred finishes (minor impurities), intermetallic growth, content of IMC, brittleness depend on solved elements/IMC, fatigue resistance, damage mechanism, affinity against oxygen, reduction potential, decontamination efforts, endo-/exothermic reactions, diffusion properties related to finishes or bare materials, isothermal fatigue, thermo-cyclic fatigue, corrosion properties, lifetime prediction based on board level results, compatibility with rework/repair solders, rework temperatures of modified solders (Impurities, change in the melting point or range), compatibility to components and laminates.

  • PDF

New Generation of Lead Free Solder Spheres 'Landal - Seal'

  • Walter H.;Trodler K. G.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.09a
    • /
    • pp.211-219
    • /
    • 2004
  • A new alloy definition will be presented concerning increasing demands for the board level reliability of miniaturized interconnections. The damage mechanism for LFBGA components on different board finishes is not quite understood. Further demands from mobile phones are the drop test, characterizing interface performance of different package constructions in relation to decreased pad constructions and therefore interfaces. The paper discusses the characterization of interfaces based on SnPb, SnPbXYZ, SnAgCu and SnAgCuInNd ball materials and SnAgCuInNd as solder paste, the stability after accelerated tests and the description of modified interfaces stric시y related to the assembly conditions, dissolution behavior of finishes on board side and the influence of intermetallic formation. The type of intermetallic as well as the quantity of intermetallics are observed, primaliry the hardness, E modules describing the ability of strain/stress compensation. First results of board level reliability are presented after TCT-40/+150. Improvement steps from the ball formulation will be discussed in conjunction to the implementation of lead free materials. In order to optimize ball materials for area array devices accelareted aging conditions like TCTs were used to analyze the board level reliability of different ball materials for BGA, LFBGA, CSP, Flip Chip. The paper outlines lead-free ball analysis in comparison to conventional solder balls for BGA and chip size packages. The important points of interest are the description of processability related to existing ball attach procedures, requirements of interconnection properties and the knowledge gained the board level reliability. Both are the primary acceptance criteria for implementation. Knowledge about melting characteristic, surface tension depend on temperature and organic vehicles, wetting behavior, electrical conductivity, thermal conductivity, specific heat, mechanical strength, creep and relaxation properties, interactions to preferred finishes (minor impurities), intermetallic growth, content of IMC, brittleness depend on solved elements/IMC, fatigue resistance, damage mechanism, affinity against oxygen, reduction potential, decontamination efforts, endo-/exothermic reactions, diffusion properties related to finishes or bare materials, isothermal fatigue, thermo-cyclic fatigue, corrosion properties, lifetime prediction based on board level results, compatibility with rework/repair solders, rework temperatures of modified solders (Impurities, change in the melting point or range), compatibility to components and laminates.

  • PDF

Crystal Structure and Polarization Properties of Ferroelectric Nd-Substituted $Bi_4Ti_3O_{12}$ Thin Films Prepared by MOCVD (강유전체 $(Bi,Nd)_4Ti_3O_{12}$ 박막의 결정 구조와 분극 특성)

  • Kang, Dong-Kyun;Park, Won-Tae;Kim, Byong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.135-136
    • /
    • 2006
  • Bismuth titanate ($Bi_4Ti_3O_{12}$, BIT) thin film has been studied intensively in the past decade due to its large remanent polarization, low crystallization temperature, and high Curie temperature. Substitution of various trivalent rare-earth cations (such as $La^{3+}$, $Nd^{3+}$, $Sm^{3+}$ and $Pr^{3+}$) in the BIT structure is known to improve its ferroelectric properties, such as remanent polarization and fatigue characteristics. Among them, neodymuim-substituted bismuth titanate, ((Bi, Nd)$_4Ti_3O_{12}$, BNT) has been receiving much attention due to its larger ferroelectricity. In this study, Ferroelectric $Bi_{3.3}Nd_{0.7}Ti_3O_{12}$ thin films were successfully fabricated by liquid delivery MOCVD process onto Pt(111)/Ti/$SiO_2$/Si(l00) substrates. Fabricated polycrystailine BNT thin films were found to be random orientations, which were confirmed by X-ray diffraction and scanning electron microscope analyses. The remanent polarization of these films increased with increase in annealing temperature. And the film also demonstrated fatigue-free behavior up to $10^{11}$ read/write switching cycles. These results indicate that the randomly oriented BNT thin film is a promising candidate among ferroelectric materials useful for lead-free nonvolatile ferroelectric random access memory applications.

  • PDF

Clinical Usefulness of Fatigue Severity Scale for Patients with Fatigue, and Anxiety or Depression (피로와 우울.불안증 환자에서 Fatigue Severity Scale의 임상적 유용성)

  • Chung, Koo-In;Song, Chan-Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.9 no.2
    • /
    • pp.164-173
    • /
    • 2001
  • Objectives : Fatigue is a common symptom in primary medical care and has nonspecific and highly subjective features. So it has been difficult to define and measure fatigue, especially those present without any organic diseases. This study was conducted to evaluate the validity of the Fatigue severity scale(FSS) in patients with persistent fatigue who were free of any organic diseases or psychiatric disorders of depression or anxiety. Methods : Subjects consisted of 45 controls, 44 fatigued patients and 43 psychiatric patients with depression or anxiety. They all completed the fatigue severity, modified Bepsi stress, and Hospital anxiety and depression scales. Chalder fatigue scale was administrated randomly in 30 of them. Data were analyzed for reliability and validity of the FSS. Results: Cronbach's a coeffient of FSS was 0.929, and the Pearson correlation coefficient for test-retest was 0.916(p<0.01). ANCOVA for discriminant validity revealed that there were significant differences in mean FSS values among the three groups. The fatigue group had significantly higher FSS value than the other two groups. The psychiatric group also had significantly higher FSS value than the control group. The Pearson correlation coefficient for convergent validity by comparing FSS with Chalder fatigue scale was 0.782(p<0.01). Using FSS index 3.22 as the cut-off point, sensitivity was 84.1% and specificity was 85.7% for the fatigue and control groups, respectively. Conclusion : Results suggested the clinical application of the FSS to be a useful measurement for distinguishing fatigue between patients with physiologic fatigue and psychiatric patients with depression or anxiety.

  • PDF

Application of the Murakami Approach for Prediction of Surface Fatigue of Cemented Carbides

  • Sergejev, Fjodor;Kubarsepp, Jakob;Preis, Irina
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.633-634
    • /
    • 2006
  • The aim of present work is to link geometrical parameter of maximum area of structural defect $\sqrt{area}\;_{max}$ (proposed by Y. Murakami, 1983) with surface fatigue mechanisms. Determined relations allow making predictions of surface fatigue properties of cemented carbides (WC-Co hardmetal - H15 - 85wt% WC and 15wt %Co, TiC-based cermets - T60/8 - 60wt %TiC and Fe/8wt% Ni and T70/14 - 70wt %TiC and Fe/14wt% Ni) in conditions of rolling contact and impact cycling loading. Pores considered being equivalent to small defects. Three comparative defects conditions are distinguished: surface pore, just below free surface and interior pores. The Vickers hardness of binder (as main responsible for the fracture mechanism of hardmetal and cermets) assumed to be the basis of such assumption. The estimate of this prediction has been done by analyzing the pore sizes using the statistics of extremes. The lower bound of fatigue properties can be correctly predicted by considering the maximum occurring pore size.

  • PDF

Crack localization by laser-induced narrowband ultrasound and nonlinear ultrasonic modulation

  • Liu, Peipei;Jang, Jinho;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • v.25 no.3
    • /
    • pp.301-310
    • /
    • 2020
  • The laser ultrasonic technique is gaining popularity for nondestructive evaluation (NDE) applications because it is a noncontact and couplant-free method and can inspect a target from a remote distance. For the conventional laser ultrasonic techniques, a pulsed laser is often used to generate broadband ultrasonic waves in a target structure. However, for crack detection using nonlinear ultrasonic modulation, it is necessary to generate narrowband ultrasonic waves. In this study, a pulsed laser is shaped into dual-line arrays using a spatial mask and used to simultaneously excite narrowband ultrasonic waves in the target structure at two distinct frequencies. Nonlinear ultrasonic modulation will occur between the two input frequencies when they encounter a fatigue crack existing in the target structure. Then, a nonlinear damage index (DI) is defined as a function of the magnitude of the modulation components and computed over the target structure by taking advantage of laser scanning. Finally, the fatigue crack is detected and localized by visualizing the nonlinear DI over the target structure. Numerical simulations and experimental tests are performed to examine the possibility of generating narrowband ultrasonic waves using the spatial mask. The performance of the proposed fatigue crack localization technique is validated by conducting an experiment with aluminum plates containing real fatigue cracks.

Dorsal Neck Muscle Fatigue Affects Cervical Range of Motion and Proprioception in Adults with the Forward Head Posture

  • Yeo, Sang-Seok;Kwon, Jung-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.319-324
    • /
    • 2020
  • Purpose: This study was to investigate the effect of dorsal neck muscle fatigue on the cervical range of motion (CROM) and proprioception in adults with the forward head posture (FHP). Methods: Thirty pain-free subjects were enrolled in this study. All subjects were measured the forward head angle by taking the capture of the sagittal plane of their upper body to determine the FHP. Subjects were distributed into two groups: the FHP group (n=14) and Control group (n=16). All subjects were measured the CROM and the Head repositioning accuracy (HRA) for joint proprioception before and after inducing muscle fatigue of the dorsal neck. The CROM and HRA were measured in neck flexion, extension, right-left lateral flexion, and right-left rotation. Sorenson's test was used to induce muscle fatigue of the dorsal neck. Results: Total CROMs were significantly decreased after dorsal neck muscle fatigue in both groups (p<0.05). Total HRAs were significantly increased after dorsal neck muscle fatigue in the FHP group (p<0.05), but there were no significant differences in the control group (p>0.05). Total CROM changes were not significant differences between groups (p>0.05), but total HRA changes were significant differences between groups (p<0.05) except for right and left lateral flexion (p>0.05). Conclusion: Immediate CROM and proprioception reduction after the dorsal neck muscle fatigue were observed in adults with the FHP. Therefore, FHP can significantly affect the CROM and positioning consistency of cervical proprioception.

Reliability improvement of nonlinear ultrasonic modulation based fatigue crack detection using feature-level data fusion

  • Lim, Hyung Jin;Kim, Yongtak;Sohn, Hoon;Jeon, Ikgeun;Liu, Peipei
    • Smart Structures and Systems
    • /
    • v.20 no.6
    • /
    • pp.683-696
    • /
    • 2017
  • In this study, the reliability of nonlinear ultrasonic modulation based fatigue crack detection is improved using a feature-level data fusion approach. When two ultrasonic inputs at two distinct frequencies are applied to a specimen with a fatigue crack, modulation components at the summation and difference of these two input frequencies appear. First, the spectral amplitudes of the modulation components and their spectral correlations are defined as individual features. Then, a 2D feature space is constructed by combining these two features, and the presence of a fatigue crack is identified in the feature space. The effectiveness of the proposed fatigue crack detection technique is experimentally validated through cyclic loading tests of aluminum plates, full-scale steel girders and a rotating shaft component. Subsequently, the improved reliability of the proposed technique is quantitatively investigated using receiver operating characteristic analysis. The uniqueness of this study lies in (1) improvement of nonlinear ultrasonic modulation based fatigue crack detection reliability using feature-level data fusion, (2) reference-free fatigue crack diagnosis without using the baseline data obtained from the intact condition of the structure, (3) application to full-scale steel girders and shaft component, and (4) quantitative investigation of the improved reliability using receiver operating characteristic analysis.

Diagnosis and Monitoring of Socket Welded Pipe Damaged by Bending Fatigue Using Acoustic Emission Technique (음향방출법을 이용한 굽힘피로 손상된 소켓용접배관의 진단 및 감시)

  • Kim, C.S.;Oh, S.W.;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.323-330
    • /
    • 2008
  • High cycle bending fatigue of socket welded small bore pipe was characterized, and also the fatigue crack initiation of small bore pipe was monitored in situ by the acoustic emission (AE) technique. The STS 316L stainless steel specimens were prepared by gas tungsten arc welding (GTAW) process having the artificial defect (i.e., lack of penetration) and defect free at the root. The fatigue failure was occurred at the loc for high stress and root for relatively low stress. The crack initiation cycles ($N_i$) was defined to the abrupt increase in AE counts during the fatigue test, and then the cracks were observed by the radiographic test and electron microscope before and after the fatigue crack initiation cycles. The socket welded pipe damaged by bending fatigue was studied regarding the welding defect, failure mode, and crack initiation cycles for the diagnosis and monitoring.

Randomized, Double-blind, and Placebo-controlled a Clinical Study for Chronic Fatigue via the Analysis of Efficacy and Safety of Gongjin-dan and Ssanghwa-tang : Study Protocol (만성피로에 대한 공진단과 쌍화탕의 안전성 및 유효성 평가를 위한 무작위배정, 이중눈가림, 위약대조 임상시험 : 임상연구 프로토콜)

  • Jun-Yong, Choi;Byungmook, Lim;Hyeun-kyoo, Shin;Kibong, Kim
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.97-108
    • /
    • 2022
  • Objectives : The purpose of this study is to confirm the efficacy and safety of Gongjin-dan and Ssanghwatang for chronic fatigue. Methods : A total of 90 people, between 19 and 65 years old, will be recruited to participate in a randomized, double-blind, and placebo-controlled a clinical trial. Participants in the Gongjin-dan group will take one pill of Gongjin-dan along with three packs of placebo oral liquid Ssanghwa-tang per day for 4 weeks. Participants in the Ssanghwa-tang group will take three packages of liquid Ssanghwa-tang and one placebo Gongjindan pill per day for 4 weeks. In the placebo group, participants will take one pill of placebo Gongjin-dan and three packs of placebo liquid Ssanghwa-tang per day, for 4 weeks. Outcomes will be measured at the baseline, 4th week, and 6th week. The primary outcome is the change in the Fatigue Severity Scale (FSS). Secondary outcomes are the change of Multidimensional Fatigue Inventory-20 (MFI-20), Chalder Fatigue Scale (CFQ), Short-Form 36 Health Survey (SF-36), Korean Version of Schedule of Fatigue and Anergy/General Physician (SOFA/GP), Glucose, Lactate, Ammonia, Free Fatty Acid (FAA), d-ROMs&BAP, Selenium, and Cortisol. Results : This trial was approved by the institutional review board of Pusan National University Korean Medicine Hospital (registry number: PNUKHIRB 2021-10-005). Recruitment opened in November 2021 and is supposed to be completed by December 2022. Conclusions : This trial will provide clinical information to determine the efficacy and safety of Gongjindan and Ssanghwa-tang for chronic fatigue.