• Title/Summary/Keyword: Fatigue-free

Search Result 200, Processing Time 0.02 seconds

Development of Free Running Model Ship for Evaluation of the Performance of Anti-Rolling Devices (자세제어장비 성능시험을 위한 자유항주 모형선 개발)

  • Yoon Hyeon-Kyu;Lee Gyeong-Joong;Son Nam-Sun;Yang Young-Hoon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.33-39
    • /
    • 2004
  • A ship runs with various modes of motion due to waves. Among the modes, roll mainly influences on the safety of cargos and crew's fatigue. Therefore a ship equipped with anti-rolling devices are on an increasing trend. In this research, we developed a free running model ship to evaluate the performances of fin stabilizer and moving weight stabilizer. Also those performance tests were carried out through the proposed test procedure.

  • PDF

Battery-free slotted patch antenna sensor for wireless strain and crack monitoring

  • Yi, Xiaohua;Cho, Chunhee;Wang, Yang;Tentzeris, Manos M.
    • Smart Structures and Systems
    • /
    • v.18 no.6
    • /
    • pp.1217-1231
    • /
    • 2016
  • In this research, a slotted patch antenna sensor is designed for wireless strain and crack sensing. An off-the-shelf RFID (radiofrequency identification) chip is adopted in the antenna sensor design for signal modulation. The operation power of the RFID chip is captured from wireless reader interrogation signal, so the sensor operation is completely battery-free (passive) and wireless. For strain and crack sensing of a structure, the antenna sensor is bonded on the structure surface like a regular strain gage. Since the antenna resonance frequency is directly related with antenna dimension, which deforms when strain occurs on the structural surface, the deformation/strain can be correlated with antenna resonance frequency shift measured by an RFID reader. The slotted patch antenna sensor performance is first evaluated through mechanics-electromagnetics coupled simulation. Extensive experiments are then conducted to validate the antenna sensor performance, including tensile and compressive strain sensing, wireless interrogation range, and fatigue crack sensing.

Study on Surface Crack Propagation Behaviour of Mild Steel Weldment in Synthetic Sea Water (인공해수중에서 연강 용접부의 표면구열 성장거동)

  • 이종기;정세희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.492-501
    • /
    • 1990
  • It was known that the fracture incidences of offshore structure were mostly originated from the surface defects. Especially, in the case of the welded structures, since the welded region has some defects and incomplete beads which are apt to behave like the surface cracks, it has been necessary to evaluate the environmental effects on crack growth at HAZ for the design crack growth behaviour at multi-pall HAZ for SWS41 steel under free corrosion and cathodic protection(-0.9V vs Ag/Agcl) conditions. The results are summarized as follows ; (1) Crack growth rate of the as weld in air was faster than that of the parent and PWHT specimens over all .DELTA.K rang. (2) In free corrosion test, surface crack growth rate of the as welded was decreased in comparison with that of the parents. (3) In fatigue test under cathodic protection, cathodic electric potential(-0.9V vs Ag/Agcl) for the SWS41 steel parent was effective, while for the as welded ineffective. (4) There was a tendency that the exponent(m) of the Paris' equation was decreased in order of microhardness magnititude in air and under cathodic protection conditions and vise versa in free corrosion. (5) Fracture surface has dimples and ductile striations in air test, but transgranular cracks and brittle striations under cathodic protection test.

Debonding monitoring of CFRP strengthened RC beams using active sensing and infrared imaging

  • Sohn, Hoon;Kim, Seung Dae;In, Chi Won;Cronin, Kelly E.;Harries, Kent
    • Smart Structures and Systems
    • /
    • v.4 no.4
    • /
    • pp.391-406
    • /
    • 2008
  • This study attempts to develop a real-time debonding monitoring system for carbon fiber-reinforced polymer (CFRP) strengthened structures by continuously inspecting the bonding condition between the CFRP layer and the host structure. The uniqueness of this study is in developing a new concept and theoretical framework of nondestructive testing (NDT), in which debonding is detected without relying on previously-obtained baseline data. The proposed reference-free damage diagnosis is achieved based on the concept of time reversal acoustics (TRA). In TRA, an input signal at an excitation point can be reconstructed if the response signal measured at another point is reemitted to the original excitation point after being reversed in the time domain. Examining the deviation of the reconstructed signal from the known initial input signal allows instantaneous identification of damage without requiring a baseline signal representing the undamaged state for comparison. The concept of TRA has been extended to guided wave propagations within the CFRP-strengthened reinforced concrete (RC) beams to improve the detectibility of local debonding. Monotonic and fatigue load tests of large-scale CFRP-strengthened RC beams are conducted to demonstrate the potential of the proposed reference-free debonding monitoring system. Comparisons with an electro-mechanical impedance method and an inferred imaging technique are provided as well.

Retrospective Study of Gemcitabine Based Chemotherapy for Unresectable or Recurrent Esophagus Squamous Cell Carcinoma Refractory to First Line Chemotherapy

  • Wang, Mei;Gu, Jun;Wang, Hai-Xing;Wu, Mei-Hong;Li, Yong-Mei;Wang, Ya-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4153-4156
    • /
    • 2012
  • Purpose: To investigate the efficacy and toxicity of a combination of gemcitabine with nedaplatin (GN) or cisplatin (GC) for patients with unresectable or recurrent esophagus squamous cell carcinoma. Methods: Gemcitabine was administered at 1 g/m2 intravenously on days 1 and 8; and nedaplatin or cisplatin were administered at 80 mg/m2 intravenously on day 1. We analyzed the response rate, overall survival time, progression-free survival time, and toxicity in 21 patients treated with GN and 27 patients treated with GC. Results: In patients treated with gemcitabine plus nedaplatin, the ORR was 47.6%, the median progression-free survival time was 4.1 months, and the median survival time was 9.3 months. In patients treated with gemcitabine plus cisplatin, the ORR was 48.2%, the median progression-free survival time was 3.9 months, and the median survival time was 9.1 months, respectively. There were no statistically significant differences in ORR, PFS and OS between the two groups. In both, the most commonly observed toxicities were thrombocytopenia and fatigue. Nausea and vomiting was more frequent in the GC group than in the GN group. Conclusion: Gemcitabine based chemotherapy was effective and tolerable for patients with unresectable or recurrent esophagus squamous cell carcinoma refractory to first line chemotherapy.

An Experimental Study on the Failure Characteristics of Sn-xAg-0.5Cu Lead-free Solder (Sn-xAg-0.5Cu 무연 솔더의 파손특성에 관한 실험적 연구)

  • Jeong, Jong-Seol;Lee, Yong-Sung;Shin, Ki-Hoon;Cheong, Seong-Kyun;Kim, Jong-Hyeong;Jang, Dong-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.449-454
    • /
    • 2009
  • This paper presents an experimental study on the failure characteristics of SnAgCu lead-free solder balls. To estimate the effect of Ag, three types of SnAgCu balls are first prepared by varying the weight percent of Ag(1.0, 3.0, 4.0 wt%) and then analyzed by reliability tests such as thermal shock, high speed ball shear, and drop tests. Thermal shock test reveals that the higher the weight percent of Ag is, the longer the fatigue lift becomes. To the contrary, high speed ball-shear test and drop test show that the shear strength and the fracture toughness of solder balls are inversely proportional to the weight percent of Ag, respectively, Reasons for these observations will be further investigated In the future work.

  • PDF

A Fundamental Study on Development of Non-Welded Flexible Joint (무용접 후렉시블 조인트 개발에 관한 기초연구)

  • Oh, Choel-Hoon;Park, Hwan-Chul;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The flexible joint with bellows and flange is made by welding bellows and flange in general. The welded parts cause a crack or demage in the flexible joint due to continuous vibration and fatigue limit. This paper is concerned with development of flexible joint with non-welded, free rotation of flange and non-packing to improve fatigue failure condition between bellows and flange. The support box and support plate that are components of press part are designed to compress fore-end of bellows only without demage of bellows. The production system of flexible joint is designed with piston attached on the compression side. The simulation is performed using Deform 3D software. As the result of simulation, the shape of compressed bellows was most proper in the compression power of $157kg{\cdot}f$ and any deformation has not occurred at a part besides fore-end. The result show that the production possibility of the designed flexible joint.

The Analysis of Cushioning Properties of Corrugated Cushion (골판지를 이용한 완충 포장재의 물리적 특성에 관한 연구)

  • Choi, Seung-Jin;Shin, Joong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.1
    • /
    • pp.35-40
    • /
    • 2006
  • Cushioning systems, which are cushion material and its designed configuration, are important to protect fragile items since they act as buffers between the impact force and the fragile product. As cushioning materials, several plastic foams are commonly used in industry. However, the utilization of the plastic material has been causing a solid waste problem and pollution. Thus, as an alternative cushion material to the plastic foams, a corrugated cushion, which is considered environmentally friendly and cheap material, was put into drop tests and its impact shock attenuation was investigated. Flat and free drop data were recorded and compared to the dynamic shock of EPS cushion. In addition, the mathematical model of the shock attenuation of the corrugated cushion was developed. The result showed that the corrugated cushion gave an excellent protection for items that were subjected to the limited number of drops. There was no significant difference of the shock absorbing ability between the EPS and corrugated cushions. Energy density model of cushioning material successfully explained the mechanical behavior and fatigue of the corrugated cushions.

  • PDF

Behavior of a Balance Shaft regarding Unbalance Mass Distribution (밸런스 샤프트 불평형 질량의 분포에 따른 동적 거동 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bong-Hyun;Kwon, Sung-Jin;Kim, Hyun-Chul;Lee, Dong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.101-106
    • /
    • 2006
  • Balance shaft has a key role in reducing a engine vibration in a vehicle and widely applied for current models. Since balance shaft module consists many sub-component and each part has its own operational characteristics, some different analysis backgrounds should be integrated into one sub-part in balance shaft module and this is the main obstacles in making a design process. Moreover, the balancing shaft is rotating in high speed and such condition requires large safety factors in a design process owing to a lot of unexpected problems with the overwhelming rotation. Balance shaft is the core-component generating the intended unbalance as well as cancelling the unbalance force or moment by the engine module. So, the balance shaft should meet the high fatigue resistance not to mention of NVH performance. In this paper, a design strategy focused on balance shaft is developed to build a optimal model considering a engine vibration. Putting the unbalance mass distribution as main design parameter, some candidate model is verifed with structural and fatigue analysis and most appropriate model is proposed here.

  • PDF

Structural design and integrity evaluations for reactor vessel of PGSFR sodium-cooled fast reactor (PGSFR 소듐냉각고속로 원자로용기 설계 및 구조건전성 평가)

  • Koo, Gyeong Hoi;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.70-77
    • /
    • 2016
  • In this paper, the structural design and integrity evaluations for a reactor vessel of PGSFR sodium-cooled fast reactor(150MWe) are carried out in compliance with ASME BPV III, Division 5 Subsection HB. The reactor vessel is designed with a direct contact of primary sodium coolant to its inner surface and has a double vessel concept enclosing by containment vessel. To assure the structural integrity for 60 years design lifetime and elevated operating temperature of $545^{\circ}C$, which can invoke creep and creep-fatigue damage, the structural integrity evaluations are carried out in compliance with the ASME code rules. The design loads considered in this evaluations are primary loads and operation thermal cycling loads of normal heat-up and cool-down. From the evaluations, the PGSFR reactor vessel satisfies the ASME code limits but it was found that there is a little design margin of creep damage for inner surface at the region of cold pool free surface.