• 제목/요약/키워드: Fatigue damage coefficient

검색결과 32건 처리시간 0.025초

Shear capacity of stud shear connectors with initial damage: Experiment, FEM model and theoretical formulation

  • Qi, Jianan;Wang, Jingquan;Li, Ming;Chen, Leilei
    • Steel and Composite Structures
    • /
    • 제25권1호
    • /
    • pp.79-92
    • /
    • 2017
  • Initial damage to a stud due to corrosion, fatigue, unexpected overloading, a weld defect or other factors could degrade the shear capacity of the stud. Based on typical push-out tests, a FEM model and theoretical formulations were proposed in this study. Six specimens with the same geometric dimensions were tested to investigate the effect of the damage degree and location on the static behavior and shear capacity of stud shear connectors. The test results indicated that a reduction of up to 36.6% and 62.9% of the section area of the shank could result in a dropping rate of 7.9% and 57.2%, respectively, compared to the standard specimen shear capacity. Numerical analysis was performed to simulate the push-out test and validated against test results. A parametrical study was performed to further investigate the damage degree and location on the shear capacity of studs based on the proposed numerical model. It was demonstrated that the shear capacity was not sensitive to the damage degree when the damage section was located at 0.5d, where d is the shank diameter, from the stud root, even if the stud had a significant reduction in area. Finally, a theoretical formula with a reduction factor K was proposed to consider the reduction of the shear capacity due to the presence of initial damage. Calculating K was accomplished in two ways: a linear relationship and a square relationship with the damage degree corresponding to the shear capacity dominated by the section area and the nominal diameter of the damaged stud. This coefficient was applied using Eurocode 4, AASHTO LRFD (2014) and GB50017-2003 (2003) and compared with the test results found in the literature. It was found that the proposed method produced good predictions of the shear capacity of stud shear connectors with initial damage.

승용차용 세라믹 촉매 담체의 열적 내구성의 실험적 평가 (Experimental Estimation of Thermal Durability in Ceramic Catalyst Supports for Passenger Car)

  • 백석흠;김성용;승삼선;양협;주원식;조석수
    • 대한기계학회논문집A
    • /
    • 제31권12호
    • /
    • pp.1157-1164
    • /
    • 2007
  • Ceramic honeycomb structures have performed successfully as catalyst supports for meeting hydrocarbon, carbon monoxide and nitrous emissions standards for gasoline-powered vehicles. Three-way catalyst converter has to withstand high temperature and thermal stress due to pressure fluctuations and vibrations. Thermal stress constitutes a major portion of the total stress which the ceramic catalyst support experiences in service. In this study, temperature distribution was measured at ceramic catalyst supports. Thermal durability was evaluated by power series dynamic fatigue damage model. Radial temperature gradient was higher than axial temperature gradient. Thermal stresses depended on direction of elastic modulus. Axial stresses are higher than tangential stresses. Tangential and axial stresses remained below thermal fatigue threshold in all engine operation ranges.

국산 에폭시 아스팔트 혼합물의 물리.역학적 특성 평가 (Evaluation of Physical and Mechanical Characteristics of Korean Epoxy Asphalt Mixtures)

  • 김병헌;백종은;이현종;박희문
    • 한국도로학회논문집
    • /
    • 제14권1호
    • /
    • pp.17-24
    • /
    • 2012
  • 본 연구에서는 다양한 실내시험을 통하여 국내에서 개발된 에폭시 아스팔트 혼합물의 공용성을 평가하였다. 최대입경 13mm의 밀입도 혼합물을 기초로 하여 아스팔트 바인더의 20% 또는 40%를 국산 및 일본산 에폭시 수지로 치환하여 4종류의 에폭시 아스팔트 혼합물의 배합 설계를 실시하였다. 에폭시 아스팔트의 가사시간이 에폭시 수지가 40% 사용한 경우 3시간, 20% 사용한 경우 6시간 정도임을 확인할 수 있었다. 휠트랙킹 시험, 간접인장 반복시험, 그리고 저온 휨 시험 결과 국산 및 일본산 에폭시 아스팔트 혼합물의 공용성이 일반 아스팔트 혼합물 보다 상당히 우수한 것으로 나타났다. 하지만 일부 에폭시 아스팔트 혼합물에서는 수분손상 가능성을 확인할 수 있었다. 또한 일본산 에폭시 아스팔트 혼합물과 국산 에폭시 아스팔트는 유사한 성능을 나타냈다. 또한 콘크리트 보수재로 개발한 국산 에폭시 아스팔트의 적합성을 평가하기 위하여 추가적으로 열팽창계수, 부착강도, 인장강도를 측정한 결과, 일반 콘크리트와의 부착력은 우수하고 인장강도는 유사한 것으로 나타났으나 열팽창계수는 5배정도 큰 것으로 나타났다.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

와이블-역승법을 이용한 기계류부품의 가속시험 방법 개발 (Development of accelerated life test method for mechanical components using Weibull-IPL(Inverse Power Law) model)

  • 이근호;김형의;강보식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.445-450
    • /
    • 2003
  • This study was performed 10 develop the accelerated life test method using Weibull-IPL(Inverse Power Law) model for mechanical components. Weibull-IPL model is concerned with determining the assurance life with confidence level and the accelerated life test time From the relation of weibull distribution factors and confidence limit, the testing times on the no number of failure acceptance criteria arc determined. The mechanical components generally represent wear and fatigue characteristics as a failure mode. IPL based on the cumulative damage theory is applied effectively the mechanical components to reduce the testing time and to achieve the accelerating test conditions. As the actual application example, accelerated life test method of agricultural tractor transmission was described. Life distribution of agricultural tractor transmission was supposed to follow Weibull distribution and life test time was calculated under the conditions of average life (MTBF) 3,000 hours and 90% confidence level for one test sample. According to IPL, because test time call be shorten in case increase test load test time could be reduced by 482 hours when we put the load 1.1 times of rated load than 0.73 times of rated load that is equivalent load calculated by load spectrum of the agricultural tractor. This time, acceleration coefficient was 11.7.

  • PDF

선회주행 시 차체의 비틀림 특성에 관한 연구 (A Study on Torsional Characteristics of the Car Body Types at Cornering Motion)

  • 이준성;조성규
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.739-744
    • /
    • 2017
  • 탄성변형과 피로손상은 카트의 주행성능에 영향을 미치는 것으로 카트 프레임에 영구변형을 유발할 수 있다. 카트프레임은 현가장치와 다른 장치를 포함하지 않으므로 두 가지 변형에 결정적인 영향을 미칠 수 있는 코너주행 시 동적 거동은 비틀림 변형이 원인이 된다. 선회주행 시 카트의 동적 거동을 분석하기 위해 카트의 GPS추적이 실시간으로 이루어지고 카트 프레임에 작용하는 비틀림 응력값을 측정하였다. 레저카트와 레이싱카트의 재료물성치들은 인장실험을 통해 얻었다. 비틀림 응력집중과 프레임 변형은 얻어진 결과 값을 토대로 프레임의 응력해석을 통하여 파악하였다. 개발된 주행분석장치를 이용하여 레저카트와 레이싱카트를 각 조건별로 실차실험을 수행하였고 이를 통한 코너에서 카트의 주행거동을 살펴보았다. 카트가 곡선주행 시 원심력으로 인해 하중이동이 발생하였으며 카트프레임에 비틀림 응력이 발생하였다. 예를 들어 레저카드의 경우, 40 km/h의 속도로 운전할 때 최대 비틀림 피로한도를 측정한 최대 비틀림응력은 230 MPa이며 비틀림 피로한도계수는 0.65를 나타내었다. 뿐만 아니라 카트의 선회 시 운전요소들을 운전측정시스템을 인스톨한 실측장비에서 측정하였으며 카트의 운전거동은 수직변위에 의해 측정하였다.

원심압축기 밀폐형 임펠러 형상에 따른 성능특성 파악을 위한 유동해석 (Flow Analysis for Performance Characteristics with Closed Type Impeller Shapes of a Centrifugal Compressor)

  • 조종재;윤용상;조명환;강석철
    • 한국추진공학회지
    • /
    • 제21권1호
    • /
    • pp.26-35
    • /
    • 2017
  • 원심압축기 운전 중에 발생하는 고주기 피로균열이나 공진 등은 임펠러 파손의 주된 원인이다. 이러한 파손을 회피하기 위해 공진영역 운전에서도 견딜 수 있는 충분한 강도의 임펠러를 설계하거나, 공진이 발생하지 않도록 임펠러를 튜닝 한다. 이러한 회피설계는 임펠러 내부유동 및 성능특성 변화를 야기하게 된다. 본 연구에서는 밀폐형 임펠러에 대해 블레이드 두께를 증가시킨 모델과 스켈럽을 적용한 모델에 대한 유동 및 성능특성을 파악하기 위해 전산해석을 수행하였다. 전산해석 결과, 블레이드 두께 증가 모델 경우는 기본모델 대비 압력계수가 0.5% 감소하였으며, 전효율은 0.1% 감소하였다. 스켈럽 적용모델은 압력계수가 0.4% 증가하였으며, 전효율은 1.6% 감소하였다.

아크릴 수지로 코팅한 배수성 아스팔트 콘크리트의 특성 평가 (Characterization of Porous Asphalt Concrete Coated with MMA Resin)

  • 최태준;이현종;김태우;송재혁
    • 한국도로학회논문집
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 2009
  • 본 연구는 배수성 아스팔트 포장의 표면을 아크릴 수지로 코팅 처리할 경우 내구성 측면 및 기능적 측면에서 어떠한 효과가 있는가를 실내시험을 통해 평가하는 기초적인 연구이다. 포장의 내구성 측면에서는 칸타브로 및 휠트래킹, 수분손상 간접 인장 피로 시험 등을 실시하였다. 시험결과 시편을 수지로 코팅을 한 경우 칸타브로 손실률이 3배 정도 감소되었고 균열에 대한 저항성도 대폭 향상되었으나 수분손상 및 소성변형의 저항성은 큰 차이가 없는 것으로 나타났다. 기능적인 측면에서는 코팅 전 후의 투수계수 및 공극률 BPT(British Pendulum Tester)를 사용한 미끄럼 저항성의 변화를 측정하였다. 시험결과 공극률 및 투수계수는 약간 저하되나 기능상의 문제는 없을 것으로 판단되며, 미끄럼 저항성은 규사를 살포하지 않을 경우 미끄럼 저항성이 감소되나 규사를 살포할 경우 코팅 전 수준 이상의 미끄럼 저항성을 확보하는 것으로 나타났다.

  • PDF

Wind-induced mechanical energy analyses for a super high-rise and long-span transmission tower-line system

  • Zhao, Shuang;Yan, Zhitao;Savory, Eric;Zhang, Bin
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.185-197
    • /
    • 2022
  • This study aimed to analyze the wind-induced mechanical energy (WME) of a proposed super high-rise and long-span transmission tower-line system (SHLTTS), which, in 2021, is the tallest tower-line system with the longest span. Anew index - the WME, accounting for the wind-induced vibration behavior of the whole system rather than the local part, was first proposed. The occurrence of the maximum WME for a transmission tower, with or without conductors, under synoptic winds, was analyzed, and the corresponding formulae were derived based on stochastic vibration theory. Some calculation data, such as the drag coefficient, dynamic parameters, windshielding areas, mass, calculation point coordinates, mode shape and influence function, derived from wind tunnel testing on reducedscale models and finite element software were used in calculating the maximum WME of the transmission tower under three cases. Then, the influence of conductors, wind speed, gradient wind height and wind yaw angle on WME components and the energy transfer relationship between substructures (transmission tower and conductor) were analyzed. The study showed that the presence of conductors increases the WME of transmission towers and changes the proportion of the mean component (MC), background component (BC) and resonant component (RC) for WME; The RC of WME is more susceptible to the wind speed change. Affected by the gradient wind height, the WME components decrease. With the RC decreasing the fastest and the MC decreasing the slowest; The WME reaches the its maximum value at the wind yaw angle of 30°. Due to the influence of three factors, namely: the long span of the conductors, the gradient wind height and the complex geometrical profile, it is important that the tower-line coupling effect, the potential for fatigue damage and the most unfavorable wind yaw angle should be given particular attention in the wind-resistant design of SHLTTSs

풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석 (Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests)

  • 이두영;구재량;박수만;김동환
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.79-88
    • /
    • 2017
  • 본 논문은 송전선로 갤러핑 현상 분석을 위해 요구되는 비대칭 송전선의 공기력 계수 측정에 관한 것으로, 세 종류의 비대칭 단면으로 구성된 단도체, 2도체 및 4도체 모형에 대해서 난류 조건에서의 풍동실험을 수행하였다. 송전선로 갤러핑은 비대칭의 착빙된 송전선에 안정된 바람이 작용하는 경우 발생하는 유체유발진동의 한 종류로, 상간 이격거리와 송전탑 하중의 계산 등 송전선의 설계시 고려해야하는 주요 인자 중 하나이다. 갤러핑에 의해 발생하는 반복적인 변동 하중은 송전선을 포함한 체결 부품 등에 큰 동응력을 발생시키는 것을 고려하여, 송전선을 비롯한 각종 부품은 마모와 피로손상에 견딜 수 있는 충분한 내구성을 가져야 한다. 국내에서도 빙설해에 의한 송전선로의 고장은 급격한 전압 강하로 인한 전기 품질에 큰 영향을 끼치는 주요 원인이 되고 있으며, 매년 약 20건 이상씩 발생하고 있는 점을 고려해, 안정적인 전력 공급과 유지, 보수 비용을 절감하기 위해서 갤러핑 현상에 대해서 기초부터 체계적인 접근이 요구되고 있다.