• 제목/요약/키워드: Fatigue cracking

검색결과 255건 처리시간 0.029초

Laboratory Evaluation of the Properties of Sulfur Modified Asphalt Mixtures (황이 첨가된 개질 아스팔트 혼합물의 실내 물성 평가)

  • Yang Sung-Lin;Kim Boo-Il;Kim Nam-Ho;Rhee Suk-Keun
    • International Journal of Highway Engineering
    • /
    • 제8권3호
    • /
    • pp.163-172
    • /
    • 2006
  • This study evaluated the laboratory properties of asphalt binder and mixture modified with SPC(Sulfur Polymer Cement), which consists of sulfur as a main ingredient that is an industrial by-product made from refining process of crude oil and carbon-black as an additive. Four levels of SPC modifier ratios(0, 10, 30, 50%) were evaluated in the laboratory. Superpave(Superior Performing Asphalt Pavements) system was used to determine the PG(Performance Grade) and evaluate the property of SPC modified binder at the different temperatures. IDT(Indirect Tensile Test) was performed to evaluate the resistance of fatigue and low-temperature cracking at $10^{\circ}C\;and\;-10^{\circ}C$. Wheel-tracking test was also performed to evaluate the rutting-resistance of SPC modified asphalt mixtures. Test results showed that the more SPC modifier ratios, the better rutting-resistance and the more potential of low-temperature cracking resistance. However, SPC modifier did not show the effect on the fatigue cracking resistance.

  • PDF

Fatigue Characteristics of Asphalt Concrete Based on compacted Density (아스팔트 콘크리트의 다짐도에 따른 피로 특성)

  • 김광우;이병덕;박용철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.205-210
    • /
    • 1994
  • This study was conducted to evaluate performance of asphalt concretes under various densities, using Marshall specimens before and after freezing-and-thawing treatment. Six different compaction blows per side (20, 30, 40, 50, 60, 70 blows) were applied to specimens to produce different densities. Test results showed that the lower density specimens had the weaker resistance to freezing-and-thawing treatment. The density was an index of retaining fatigue life and displacement after freezing-and-thawing. Therefore, poor compaction in pavement was considered to be a major cause of early distress mechanisms such as rutting, ravelling and cracking, which were resulted in a reduced service life.

  • PDF

Study on Localized Corrosion Cracking of Alloy 600 using EN-DCPD Technique (EN-DCPD 방법을 이용한 Alloy 600 재료의 국부부식균열 연구)

  • Lee, Yeon-Ju;Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • 제12권2호
    • /
    • pp.93-101
    • /
    • 2013
  • The object of this work is to establish an electrochemical noise(EN) measurement technique combined with a direct current potential drop(DCPD) method for monitoring of localized corrosion cracking of nickel-based alloy, and to analyze its mechanism. The electrochemical current and potential noises were measured under various conditions of applied stress to a compact tension specimen in a simulated primary water chemistry of a pressurized water reactor. The amplitude and frequency of the EN signals were evaluated in both time and frequency domains based on a shot noise theory, and then quantitatively analyzed using statistical Weibull distribution function. From the spectral analysis, the effect of the current application in DCPD was found to be effectively excluded from the EN signals generated from the localized corrosion cracking. With the aid of a microstructural analysis, the relationship between EN signals and the localized corrosion cracking mechanism was investigated by comparing the shape parameter of Weibull distribution of a mean time-to-failure.

Fatigue Characteristic of Bearing Steel(STB2) in Gigacycle (베어링강의 기가사이클 피로 특성에 관한 연구)

  • KIM SANG-CHUN;SUH CHANG-MIN;HWANG BYUNG-WON;LEE TAE-SUNG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.370-375
    • /
    • 2004
  • Fatigue tests were carried out to find the fatigue characteristics in the super-long life range by using a cantilever type rotational bending fatigue test machine. Three kinds of specimen in bearing steels with the quenched and tempered in air (A and B, B: shot peened after heal treatment) and under vacuum conditions(C:non-shot peened)were tested in this study. S-N curves obtained from fatigue tests of C specimen tend to come dawn again in the super-long life range due to fish-eye type cracking, while most of A and B specimens fractured by surface defects such as scratches and slip lines. This duplex S-N behavior for the high strength steels have to be reviewed by the change of fracture modes.

  • PDF

Fatigue Behavior of Steel Fiber Reinforced Concrete Continuous Beams under Cyclic Loading (반복하중하에서 강섬유보강 철근콘크리트 연속보의 피로거동)

  • Kwak, Kae-Hwan;Park, Jong-Gun;Jang, Hwa-Sup
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제46권6호
    • /
    • pp.47-58
    • /
    • 2004
  • As concrete structures are getting larger, higher, longer and more specialized, it is more required to develop steel fiber concrete and apply to the real world. In this research, it is aimed to have fatigue strength examined, varying the steel fiber content of 0%, 0.75%, 1.00%, 1.25% by experimental study of fatigue behavior of the steel fiber reinforced concrete continuous beams under cyclic loading. The ultimate load and initial load of flexural cracking were measured by static test. In addition, the load versus strain relation, load versus deflection relation, crack pattern and fracture mode by increasing weight were observed. On the other hand, the crack propagation and the modes of fracture according to cycle number and the relation of cyclic loading to deflection relation and strain relation were investigated by fatigue test. As the result of fatigue test, continuous beam without steel fiber was failed at 60 ~ 70% of The static ultimate strength and it could be concluded that fatigue strength to two million cyclic loading was arround 67.2% by S-N curve. On the other hand, that with steel fiber was failed at 65 ~ 85% of the static ultimate strength and it could be concluded fatigue strength to two million cyclic loading around 71.7%.

Environmental Fatigue Behaviors of Austenitic Stainless Steels in the Primary Water Environment of Nuclear Power Plants (원전일차측 환경에서 오스테나이트계 스테인리스강의 환경피로특성)

  • Lee, Hyeon Bae;Kim, Ho-Sub;Kim, Taesoon;Jang, Changheui
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • 제13권2호
    • /
    • pp.19-30
    • /
    • 2017
  • Austenitic Stainless Steels (ASSs) are widely used as structural materials in the pressurized water reactors (PWRs) because of their superior mechanical properties and corrosion resistance. However, it is well known that ASSs are susceptible to the environmental assisted cracking (EAC) such as environmental assisted fatigue (EAF) during the long term operation. There have been extensive tests and researches to understand the extent and the mechanisms of environmental effects. In this paper, the world-wide EAF test results of ASSs are introduced including those of Korean test programs. The suggested EAF mechanisms of ASSs are also discussed. Finally, the areas of further research to resolve the issue of EAF are suggested.

An implicit damage-plastic model for concrete

  • Gustavo Luz Xavier da Costa
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.301-308
    • /
    • 2024
  • This paper proposes a numerically-based methodology to implicitly model irreversible deformations in concrete through a damage model. Plasticity theory is not explicitly employed, although resemblances are still present. A scalar isotropic damage model is adopted and the damage variable is split in two: one contributing for stiffness degradation (cracking) and other contributing for irreversible deformations (plasticity). The proposed methodology is thermodynamically consistent as it consists in a damage model rewritten in different terms. Its Finite Element coding is presented, indicating that minor changes are necessary. It is also demonstrated that nonlinear algorithms are unnecessary to model concrete cracking and plasticity. Experimental data from direct tension and four-point bending tests under cyclic loading are compared to the proposed methodology. A numerical case study of a low-cycle fatigue is also presented. It can be concluded that the model is simple, feasible and capable to capture the essentials concerning cracking and plasticity.

Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method (변형률분할법에 의한 12Cr 단조강의 열피로 수명예측)

  • 하정수;옹장우;고승기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제18권5호
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

Cause of Fatigue Failure of the First Blade of 100-MW Gas Turbine (100 MW급 가스터빈 1단 블레이드의 피로파괴 발생 원인)

  • Youn, Hee-Chul;Woo, Chang-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제24권6호
    • /
    • pp.632-638
    • /
    • 2015
  • Many failures have been reported in gas turbine facilities owing to repeated startups and prolonged use of the turbines. In this study, the causes and mechanism of fatigue failure in the first blade of a gas turbine were analyzed using a finite element method to calculate the centrifugal force, bending force, and a modal analysis based on the stress-stiffening effect and harmonic response under the operating conditions. The results show that, fatigue damage was caused by the resonance conditions encountered, in which the first natural frequency declined along with an increase in the metal temperature of the blade. The position of the expected fatigue damage was shown to match the actual position of the cracking at the root area of the blade, which was on the concave side. In addition, the equivalence fatigue stress was observed to approach the fatigue limit.

ENVIRONMENTAL FATIGUE OF METALLIC MATERIALS IN NUCLEAR POWER PLANTS - A REVIEW OF KOREAN TEST PROGRAMS

  • Jang, Changheui;Jang, Hun;Hong, Jong-Dae;Cho, Hyunchul;Kim, Tae Soon;Lee, Jae-Gon
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.929-940
    • /
    • 2013
  • Environmental fatigue of the metallic components in light water reactors has been the subject of extensive research and regulatory interest in Korea and abroad. Especially, it was one of the key domestic issues for the license renewal of operating reactors and licensing of advanced reactors during the early 2000s. To deal with the environmental fatigue issue domestically, a systematic test program has been initiated and is still underway. The materials tested were SA508 Gr.1a low alloy steels, 316LN stainless steels, cast stainless steels, and an Alloy 690 and 52M weld. Through tests and subsequent analysis, the mechanisms of reduced low cycle fatigue life have been investigated for those alloys. In addition, the effects of temperature, dissolved oxygen level, and dissolved hydrogen level on low cycle fatigue behaviors have been investigated. In this paper, the test results and key analysis results are briefly summarized. Finally, an on-going test program for hot-bending of 347 stainless steel is introduced.