• Title/Summary/Keyword: Fatigue Endurance

Search Result 210, Processing Time 0.028 seconds

Design Optimization and Endurance Assessment of Weld Area for LCD Robot Frame (LCD 로봇 주요 프레임에 대한 설계 최적화 및 용접부 수명평가)

  • Han, Sung Wook;Kang, Yun Sik;Kim, Teahyun;Kim, Sang Hyun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • LCD robot vertical frame lets a arm assembly with glass substrate move up and down, so it must have high stiffness and strength. We applied new manufacturing process by using design optimization process such as topology and size optimization in order to satisfy the request of high stiffness and light weight. The proposed model should be evaluated for endurance strength. Therefore fatigue assessment for weak point of aluminum welding area of vertical frame studied with hot spot stress approach. And the actual stress measuring from test was compared and evaluated with the dynamic stress calculated from multi-body dynamics considering flexible body.

Structural Analysis of Damping Hinge for Built-in Side-by-Side Refrigerator and Design Improvement of Bracket Pin to Reduce Stress Concentration (빌트인 양문형 냉장고 댐핑힌지의 구조해석 및 브래킷핀의 응력집중 저감을 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.373-379
    • /
    • 2020
  • This study performed stress and fatigue life analysis of the damping hinge of a built-in side-by-side refrigerator that occurs when the door is opened to the maximum angle. An analysis of the initial design showed that stress concentration occurred at the corner between the cylinder and upper disk of the bracket pin, and the maximum stress exceeded the yield strength. The maximum stress location and the calculated fatigue life were consistent with the door opening-and-closing endurance test results for a prototype. Three cases of design improvement for the bracket pin were derived with the aim of reducing the stress concentration that appeared in the initial design. An analysis of the cases showed that inserting a fillet between the disk and the cylinder of the bracket pin reduced the stress and increased the fatigue life. Moreover, changing the disk into two steps was more favorable. In conclusion, the best design improvement was the case that the disk was changed to two steps and the fillet with a large radius was inserted. In that case, the stress was the smallest and the fatigue life was infinite.

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

Assessment of Isokinetic Muscle Function in Elite Canadian College Paddlers (대학 엘리트 카나디언 선수들의 어깨·허리·무릎 관절의 등속성 근기능 평가 및 진단)

  • Shin, Kwang-Taek;An, Chang-Gyu;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.229-238
    • /
    • 2013
  • The aim of this study is to evaluate university canadian paddlers' iso-kinetic muscle function and provide training advices. Eight university paddlers with a 8.5 years career participated in this study. Inbody 720, biodex system III, biodex stabilizer system and THP 2 are used to investigate body component, muscle function(peak torque, average power and work fatigue), agility and dynamic balance. Iso-kinetic muscle function around shoulder, thorax and knee are measured. And then bilateral and unilateral muscle imbalance are calculated at each joint. Results of this study are as follows; University canadian paddlers' BMI average is 24.90 $kg/m^2$ and percent body fat is 12.23%. Reaction time average was 324 msec and balance score at each leg are below 2.0. A3, A4, A5, A6, A8 are needed to train shoulder muscle strength and power. A1, A2, A7, A8 are needed to strengthen shoulder muscle endurance. A2, A5, A8 are needed to train thorax muscle strength and power. A1, A8 are needed to strengthen thorax muscle endurance. Most of paddlers' reciprocal muscle balance ratio on thorax and knee are out of normal range. A2, A3, A4, A8 are needed to train abdominal strength and A3, A5, A6, A7, A8 are needed to train hamstring strength.

A Study of Muscle Fatigue in Lumbar and Abdominal Muscles in Patients with Chronic Low Back Pain by Electromyographic Power Spectral Analysis (근전도 스펙트럼 분석을 이용한 만성 요통 환자의 요부근육과 복부근육의 피로도 분석)

  • Nam, Ki-Seok;Lee, Young-Hee;Yi, Chung-Hwi;Cho, Sang-Hyun
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.16-31
    • /
    • 1999
  • The purpose of this study was to assess the fatigue in lumbar and abdominal muscles in patients with chronic low back pain compared with normal subjects using spectral analysis with mean power frequency and median power frequency. The experimental group consisted of twenty subjects who had experienced chronic low back pain for over one year after the onset day. A control group consisted of twenty normal subjects with no history of low back pain. All subjects stood in an apparatus to perform sustained contraction in the lumbar and abdominal muscles for 30 seconds with 60% maximal voluntary isometric contraction (MVIC). The resulting electromyographic (EMG) recorded time serial data were transformed into frequency serial data by Fast Fourier Transformation (FFT). The results were as follows: 1) lumbar muscles measured, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group group (p<0.05). In measured two abdominal muscles (inferior rectus abdominis, obliquus externus abdominis) except superior rectus abdominis, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group (p<0.05). 2) In all three (longissimus thoracis, iliocostalis lumborum, multifidus) lumbar muscles measured, the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). In the two (inferior rectus abdominis, obliquus externus abdominis) abdominal muscles measured (superior rectus abdominis not included), the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). These results suggest that in patients with chronic low back pain there is a trend for more fatigue to occur in both lumbar and abdominal muscles than in the normal control group. This would seem to suggest that in treatment programs for patients with chronic low back pain, improvement of endurance in all trunk muscles should be considered.

  • PDF

Stress-Reducing Effects of Brown Rice Koji

  • Lee, Geum-Seon;Choi, Ji-Young;Ko, Hong-Sook;Lee, Blendyl Saguan Tan;Yu, Gu-Young;Jeong, Chung-Won;Park, Hyung-Geun;Kim, Mi-Kang;Ryu, Jong-Hoon;Jung, In-Kyung;Cheong, Jae-Hoon
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The primary objective of this study is to determine whether a diet supplemented with brown rice koji (BRK) results in a reduced stress response in rats and mice. BRK, which has been suggested as a candidate for use as a stress- and fatigue-fighting supplement, was compared with red ginseng extract (RG) for its stress-reducing potential. The animals in this study were divided into no-stress, stress, RG, and BRK groups of 8 to 10 animals each. Stress was induced by means of immobilization (being restrained in plastic tubes for 30 min and electroshock (0.5 mA in mice or 2 mA in rats for 5 min). The no-stress group was not exposed to stress. Rats in the RG group received oral doses of 200 mg RG extract/kg body weight daily. The BRK group was fed a 30% BRK diet and exposed to stress. Animals were given supplements for 7 days before being exposed to stress, and then were given supplements for 5 days with exposure to stress. When the stress exposure ended, the animals were observed for stress-related changes in behavior and their plasma corticosterone levels were measured. BRK supplementation was associated with a partial blockade of the effects of stress on locomotion and elevated plus-maze test results in rats and mice. It was also associated with a partial reduction in stress-induced behaviors such as freezing, burrowing, smelling, face-washing, and rearing. BRK supplementation did not have a significant effect on plasma corticosterone levels, which were increased in the animals exposed to stress (p<0.01). The mice in the RG group received RG in water (2 mg RG/ mL $H_2O$), and the BRK group received a 30% BRK diet (weight) for 7 days. Both groups were evaluated for signs of fatigue. BRK supplementation increased endurance, as indicated by time on the rota-rod, in cold water, and on the horizontal wire. These results suggest that BRK supplementation partially protects the animal from the effects of stress and may also contribute to resistance to fatigue on physical exertion.

Spin Testing for the Endurance Verification of Gas Turbine Blades (고속회전시험기를 활용한 가스터빈 동익의 내구성 시험)

  • Lee, Dooyoung;Kim, Doosoo;Son, Taeha;Goo, Jaeryang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • The long-term research and development for the production of domestic blades has been consistently performed. As the direct and indirect results of its nationwide technologies in precision casting have been improved as well as maintenance costs for turbine machinery has been reduced. Whereas, there are still not a few concerns about the reliability of newly manufactured blades in spite of the quality certificate in metallurgical and mechanical properties. A spin tester is a machine that gives centrifugal loading to a rotating part, and its practical application is the overspeed test that is usually used to check the quality of products. A new spin rig has been constructed in KEPCO Research Institute for the purpose of evaluating the reliability of blades. In this paper, the test methodology for low cycle fatigue damage mechanism as well as the overspeed test for newly developed blades is described, and their reliability is evaluated too.

A Study on Reliability Compliance Test based on Thermal Fatigue Accelerated Test for CVVL BLDC Motor (CVVL BLDC 모터의 열피로 가속시험을 통한 수명보증시험 설계)

  • Lee, San-Hoon;Park, Sang-Wook;Kim, Min-Geiun;Seon, Han-Geol;Hong, Sung Ryeul;Han, Man-Seung
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.241-247
    • /
    • 2015
  • Purpose : The demand for higher fuel economy vehicles has helped develop fuel-efficient vehicles such as a CVVL called continuous variable valve lift. Existing CVVL has been applying DC type motor to control intake valve, but recently some car parts manufacturers have been developing a BLDC type CVVL motor for improvements of endurance performance. The purpose of this study is to find the potential failure mechanism of the CVVL BLDC moto in early stage of development based on the design properties and design the accelerated life test model. Methods : CVVL BLDC is consist of brushs, coil, magnetic, PCB, bearing and so on. Each component has a latent failure mechanism caused by temperature, humidity, vibration. By analysis result of the failure mechanism, thermal fatigue is the most important factor of a durability of CVVL BLDC motor. So, we designed a new accelerated life test model for guarantee of the CVVL BLDC motor. Results : A crack occurred on via hole in test using the conditions we designed, so we did change the design to avoid this failure. The via hole dimension is changed a little larger, as a result we achieve improvements in reliability of the CVVL BLDC motor. By applying various kinds and extreme level of stresses, we can find the operating limits of products. Conclusion : In thesis, We analyzed the failure mechanism of CVVL BLDC and designed an accelerated life test method to give a guarantee for reliability. Based on the test results, we could improve the reliability of developments by change of design.

A Study on the Shear Behavior of Reinforced Concrete Structures (철근(鐵筋)콘크리트 구조물(構造物)의 전단거동(剪斷擧動)에 관한 연구(研究))

  • Chang, Dong Il;Kwak, Kae Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.83-92
    • /
    • 1987
  • Fatigue fracture of reinforced concrete structures are characterized by considerably larger strains and microcracking as compared to fracture of R.C. structures under static loading. The strain of stirrup is increased suddenly by the occuring of inclined crack and the average strain ${\epsilon}_{\omega}$ of all stirrups in a structure at maximum load increase approximately in proportion to log N. The structures critical in longitudinal reinforcement seemed to have an endurance limit of 60~70 percent of static ultimate strengths for 1,000,000 cycles. In this test, the average fatigue strength at 1,000,000 cycles for all structures tested was approximately 65 percent of the static ultimate strength.

  • PDF

Strengthening Capacity of Bridge Deck Strengthened with Carbon Fiber Rod and Polymer Mortar (고강도 폴리머 모르타르 및 탄소섬유 봉(Rod)으로 보강된 교량 바닥판의 보강성능)

  • Sim Jongsung;Moon Do-Young;Ju Mm-Kwan
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.213-220
    • /
    • 2004
  • This paper deals with an enhanced structural capacity of reinforced concrete bridge deck strengthened with carbon fiber rod (CFR) which is subjected to monotonic and cyclic loads. Strengthening variables considered in this test were evenly and unevenly strengthening type. To evaluate strengthening capacity for these two strengthening types, load-carrying capacity and crack and failure pattern from the failure test were analyzed and fatigue response were examined. According to the test results, all the strengthened specimens showed punching shear failure as a result of premature failure of bonding interface between mortar and concrete. In the case of strengthening capacity, it was observed that the strengthened specimens was more effective in strength, stiffness and fatigue endurance limit than the unstrengthened specimen. In addition, the unevenly strengthening method (CR-UE) was more effective than the evenly strengthening method (CR-E).