• Title/Summary/Keyword: Fatigue Characteristic

Search Result 293, Processing Time 0.027 seconds

EFFECT OF SURFACE DEFECTS AND CROSS-SECTIONAL CONFIGURATION ON THE FATIGUE FRACTURE OF NITI ROTARY FILES UNDER CYCLIC LOADING (전동식 니켈 티타늄 파일의 표면 결함 및 단면 형태가 반복응력 하에서 피로 파절에 미치는 영향)

  • Shin, Yu-Mi;Kim, Eui-Sung;Kim, Kwang-Man;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.267-272
    • /
    • 2004
  • The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files ($K3^{TM},{\;}ProFile^{\circledR},{\;}and{\;}HERO{\;}642^{\circledR}$) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups : control (no surface defects) and experimental group (artificial surface defects), A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the $K3^{TM}$ (p<0.05), There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks. This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.

Validity Study of the Systemic Exertion Intolerance Disease Questionnaire (SEID-Q27) for Chronic Fatigue Syndrome (CFS) Diagnosis (SEID(Systemic Exertion Intolerance Disease) 진단 기준을 바탕으로 한 만성 피로 증후군 진단 설문지(SEID-Q27) 타당도 연구)

  • Lim, Eun-jin;Son, Chang-gue;Jang, Eun-su
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.6
    • /
    • pp.1015-1029
    • /
    • 2020
  • Purpose: This study assessed the validity of a questionnaire (SEID-Q27) for diagnosis of chronic fatigue syndrome (CFS), designed based on the systematic exertion intolerance disorder (SEID) criteria. Methods: Two groups of participants were recruited: 1. a non-CFS control group: adult university personnel with a Chalder fatigue scale (CFQ) score ≥15, and 2. a CFS patient group: patients from an online CFS community diagnosed with CFS (diagnostic code of G93.3) with the symptoms present. The survey ran from September to October, 2020. The validity of the questionnaire was investigated by factor analysis and receiver operator characteristic (ROC) analysis. Results: Among the 35 adults surveyed, 30 (86%) participants had CFQ scores ≥15 (15 males and 15 females) and 5 (14%) had a CFS diagnosis (2 males and 3 females). The total mean score was significantly different between the two groups (CFS: 6.8±2.2 vs. control: 4.4±2.4, p<0.05). The area under the curve (AUC) was 0.827. With a cut-off point 62, the sensitivity was 60%, specificity 97%, and the discriminant ability of the survey was 79%. Conclusions: The SEID -Q27 appears to be a useful instrument for the diagnosis of CFS using SEID criteria. However, further large-scale studies are needed with greater numbers of participants.

An Experimental Study on the Fatigue Flexural Bonding Characteristic of Concrete Beam Reinforced with GFRP Rebar (GFRP Rebar로 보강된 콘크리트보의 피로 휨·부착성능에 관한 실험적 연구)

  • Oh, Hong Seob;Sim, Jong Sung;Kang, Tae-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • This study is to examine bond strength of beam reinforced with GFRP rebar under 4-point fatigue bending test by adopting BRITISH STANDARD. The variables were made to have bonding length of 5times(5db), and 15times(15db) of the nominal diameter of GFRP rebar and were done to analyze the relationship between the bonding strength and the slip. In the result of the test, pull-out failure was dominant in the 5db specimen, patterns of the pull-out failure and concrete shear failure appeared in the 15db specimen showed only concrete shear failure at the end of bonding length. Therefore, The strain development consist of three different stage : A rapid increases form 0 to about 10% of total fatigue life. A uniform increases form 10% to about 70%~90%. Then a rapid increases until failure, if failure takes place. It seems that stress level has not influence on the secant modules of elasticity. And also according to the outcome the existing strengthening method came out to be the most superiority in S-N graphs.

Acoustic characteristics of speech-language pathologists related to their subjective vocal fatigue (언어재활사의 주관적 음성피로도와 관련된 음향적 특성)

  • Jeon, Hyewon;Kim, Jiyoun;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.14 no.3
    • /
    • pp.87-101
    • /
    • 2022
  • In addition to administering a questionnaire (J-survey), which questions individuals on subjective vocal fatigue, voice samples were collected before and after speech-language pathology sessions from 50 female speech-language pathologists in their 20s and 30s in the Daejeon and Chungnam areas. We identified significant differences in Korean Vocal Fatigue Index scores between the fatigue and non-fatigue groups, with the most prominent differences in sections one and two. Regarding acoustic phonetic characteristics, both groups showed a pattern in which low-frequency band energy was relatively low, and high-frequency band energy was increased after the treatment sessions. This trend was well reflected in the low-to-high ratio of vowels, slope LTAS, energy in the third formant, and energy in the 4,000-8,000 Hz range. A difference between the groups was observed only in the vowel energy of the low-frequency band (0-4,000 Hz) before treatment, with the non-fatigue group having a higher value than the fatigue group. This characteristic could be interpreted as a result of voice abuse and higher muscle tonus caused by long-term voice work. The perturbation parameter and shimmer local was lowered in the non-fatigue group after treatment, and the noise-to-harmonics ratio (NHR) was lowered in both groups following treatment. The decrease in NHR and the fall of shimmer local could be attributed to vocal cord hypertension, but it could be concluded that the effective voice use of speech-language pathologists also contributed to this effect, especially in the non-fatigue group. In the case of the non-fatigue group, the rhamonics-to-noise ratio increased significantly after treatment, indicating that the harmonic structure was more stable after treatment.

A Study on Crack Initiation Measurement of Carburized Gear Tooth by Acoustic Emission (침탄치차의 AE법에 의한 크랙발생의 계측에 관한 연구)

  • 류성기
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.11-16
    • /
    • 1994
  • Acoustic emission technique is applied to the fatigue crack initiation in a carburized gear tooth. Acoustic emission test performed on carburized gear and three-point bending test equal to carburized gear hardness. The marked acoustic emission are detected at the early stage of crack initiation measured by a crack gauge and the final stage just before the tooth failure. The estimated acoustic emission energy rate are characteristic of the measured acoustic emission.

  • PDF

Ergonomic Evaluation of Color Breakup in Field-Sequential Color Projection System

  • Shibate, Takashi;Kawai, Takashi;Kim, Sang-Hyun;Ukai, Kazuhiko
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.121-124
    • /
    • 2005
  • A field-sequential color projection system can display color images using panel. However, it suffers from a characteristic trichromatic separation known as "color breakup". The viewing of images exhibiting color breakup may cause visual fatigue and mental stress. In this study, the authors examine, from the standpoint of human factors, the objective and subjective symptoms that can result from the viewing of images with color breakup.

  • PDF

Likelihood Function of Order Statistic with a Weibull Distribution (와이벌분포를 갖는 순위설계량의 우도함수)

  • Seo Nam-Su
    • Journal of the military operations research society of Korea
    • /
    • v.9 no.2
    • /
    • pp.39-43
    • /
    • 1983
  • In this paper, we derive the likelihood function for the independent random order statistic whose underlying lifetime distribution is a two parameter Weibull form. For this purpose we first discuss the order statistic which represent a characteristic feature of most life and fatigue tests that they give rise to ordered observations. And, we describe the properties of the underlying Weibull model. The derived likelihood function is essential for establishing the statistical life test plans in the case of Weibull distribution using a likelihood ratio method.

  • PDF

A Study on the furniture Design by research of working furniture in office -Focused on the furniture type of solo worker on characteristic kinds of works - (업무공간 가구 사용에 따른 가구디자인 적용에 관한 연구 - 업무특성에 따른 개인 업무자 가구구성을 중심으로 -)

  • 신동준
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.209-216
    • /
    • 2003
  • The purpose of this study is to develop furniture design for work space of Office based on the research of furniture design and the survey on the design of the office furniture. The office furniture Is designed in order to use the space flexibly and for the user design in the work space. The furniture type of solo worker on characteristic kinds of works should have a simple shape and it should be safe and easy to move because it has a structural function. The furniture in office should be designed in consideration of moveing line while working. The development of furniture in office which suit human body should be made in consideration of human factors and the study on furniture design in office. As above mentioned, to research and study on the furniture design of working furniture in office which reduces fatigue resulted from labor for office, human factors aspect should be considered, furthermore psychological, mental approach to Ideal solution should be made.

Characteristic of Refrigerant for Heat-treatment Deformation Control of SCM415 Steel (SCM415강의 열처리 변형제어를 위한 냉각 매질의 특성)

  • Ahn, Min-ju;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.6
    • /
    • pp.59-65
    • /
    • 2010
  • This study deals with the characteristic of refrigerant for heat-treatment deformation control of SCM415 steel. The control of heat-treatment deformation must need the progress of production parts for an industry machine. Most of the deformation is occurred on unequal cooling. The unequal cooling is occurred by a property of quenching refrigeration. When a heated metal is deposited in the refrigeration, the cooling speed is so slow in early period of cooling because of occurring a steam-curtain. After more cooling, the steam-curtain is destroyed. In this progress, the cooling speed is very fast. The object of this study is to control the deformation of heat-treatment for the part of the industry machine by improving the conditions of quenching. The cooling curves and cooling rates of water, oil and polymer solution are obtained and illustrated. From the characteristics of the quenching refrigerant, the effects of heat-treatments on the thermal deformation and fatigue strength are also investigated.

Material characteristic of ACSR due to eccentricity at sleeve point (ACSR 슬리브 개소에서의 송전선 재료특성 검토)

  • Kang, J.W.;Hong, D.S.;Jang, T.I.;Yoon, H.H.;Lee, D.I.;Choi, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.309-310
    • /
    • 2006
  • The considerations for remaining life of ACSR (Aluminum Stranded Conductors Steel Reinforced) in transmission lines has become gradually important to hold reliability and stability of power supply. The remaining life of ACSR exposed to the atmosphere for a long period may rely on deterioration caused by environmental indices such as atmospheric corrosion, galvanic corrosion, crevice corrosion and fatigue corrosion. This paper deals with material characteristic of ACSR due to eccentricity at sleeve point. Test samples are ACSR 240[$mm^2$] conductors, which are real transmission lines. As a result, it is obvious that ACSR due to eccentricity may lead to mechanical deterioration.

  • PDF