• 제목/요약/키워드: Fastscan

검색결과 4건 처리시간 0.019초

Bed-type과 Stand-type 상용 전신계수기(Whole Body Counter)의 성능 비교 (Performance Comparison of Bed-type and Stand-type Commercial Whole Body Counter Made by Canberra for Internal Exposure Monitoring)

  • 김봉기;하위호;권태은;박민석;이준호;김종민;이상경;정규환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.437-444
    • /
    • 2018
  • Whole-Body counters have been used to evaluate the internal contamination of gamma emitting radionuclides. Among the whole-body counters used in domestic nuclear facilities, Fastscan made by CANBERRA contains 2 NaI(Tl) detectors and is generally used to monitor the primary internal exposure. It has the advantage of achieving MDA even with short time measurements. Accuscan is a bed type, and has good energy resolution because it is composed of HPGe detector. Since the Accuscan with better energy resolution than Fastscan has better able to identify radionuclides, it is used to monitor secondary internal exposure. Some nuclear facilities have only Fastscan. We analyzed statistically whether Fastscan is enough to ensure accuracy and precision comparing with Accuscan. To do this, we prepared a CRM created by the Korea Research Institute of Standards and Science. We also obtained the data of 6 Fastscans and 5 Accuscans in domestic nuclear facilities. As a result of the study, although Fastscan compared with Accuscan is not as accurate as the Accuscan, the precision is statistically same. However, accuracy of Fastscan is in compliance with international standards except low energy range. In terms of accuracy and precision except radionuclides emitting low energy, it is possible to measure radioactivity inside workers even in nuclear facilities where only Fastscan is used.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.

몬테카를로 방법론을 이용한 측정 대상의 인체 크기와 측정 위치에 따른 전신계수기 계수효율 평가 (Assessment of Counting Efficiency of a Whole Body Counter by Human Body Size and Standing Position Using Monte Carlo Method)

  • 박민정;유재룡;하위호;이승숙;김광표
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.46-53
    • /
    • 2014
  • 방사선사고 시 내부오염 평가대상의 범위는 성인뿐만 아니라 소아까지 전 연령층으로 확대된다. 본 연구에서는 전신계수기의 측정 정확도를 향상시키기 위해 측정대상의 인체 크기와 측정 위치에 따른 계수효율을 평가하였다. 본 연구에서는 한국원자력의학원에서 사용하는 전신계수기인 FASTSCAN에 대해 방사선수송코드를 이용하여 전산 모사하였다. 측정한 계수효율과 계산한 계수효율의 상대편중은 4세 소아의 경우 2% 이하이였으며, 성인의 경우에도 5% 이하로 일치하였다. 측정 대상의 키가 작을수록 검출기와의 거리가 멀어지는 문제를 보완하고 인체 크기에 따른 계수효율의 일관적인 경향성을 도출하기 위해, 측정대상의 측정 위치를 조절하여 전신계수기의 계수효율을 평가하였다. 조절된 측정 위치에서의 전신계수기 계수효율을 바탕으로 측정 대상의 인체 크기 차이에 의한 내부오염도 평가 시 측정 오차를 줄일 수 있는 인체 크기 보정인자를 도출하였다. 도출된 보정인자는 전신계수기 측정결과에 곱하여 측정대상의 내부오염도를 쉽게 평가할 수 있으며, 궁극적으로 방사선사고 시 전신계수기를 이용한 내부오염도의 측정 정확도를 크게 향상시킬 수 있을 것이다.