• Title/Summary/Keyword: Fast reactor design

Search Result 173, Processing Time 0.03 seconds

CONCEPTUAL DESIGN OF THE SODIUM-COOLED FAST REACTOR KALIMER-600

  • Hahn, Do-Hee;Kim, Yeong-Il;Lee, Chan-Bock;Kim, Seong-O;Lee, Jae-Han;Lee, Yong-Bum;Kim, Byung-Ho;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.193-206
    • /
    • 2007
  • The Korea Atomic Energy Research Institute has developed an advanced fast reactor concept, KALIMER-600, which satisfies the Generation IV reactor design goals of sustainability, economics, safety, and proliferation resistance. The concept enables an efficient utilization of uranium resources and a reduction of the radioactive waste. The core design has been developed with a strong emphasis on proliferation resistance by adopting a single enrichment fuel without blanket assemblies. In addition, a passive residual heat removal system, shortened intermediate heat-transport system piping and seismic isolation have been realized in the reactor system design as enhancements to its safety and economics. The inherent safety characteristics of the KALIMER-600 design have been confirmed by a safety analysis of its bounding events. Research on important thermal-hydraulic phenomena and sensing technologies were performed to support the design study. The integrity of the reactor head against creep fatigue was confirmed using a CFD method, and a model for density-wave instability in a helical-coiled steam generator was developed. Gas entrainment on an agitating pool surface was investigated and an experimental correlation on a critical entrainment condition was obtained. An experimental study on sodium-water reactions was also performed to validate the developed SELPSTA code, which predicts the data accurately. An acoustic leak detection method utilizing a neural network and signal processing units were developed and applied successfully for the detection of a signal up to a noise level of -20 dB. Waveguide sensor visualization technology is being developed to inspect the reactor internals and fuel subassemblies. These research and developmental efforts contribute significantly to enhance the safety, economics, and efficiency of the KALIMER-600 design concept.

FAST REACTOR TECHNOLOGY R&D ACTIVITIES IN CHINA

  • Mi, Xu
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • The basic research on fast reactor technology was started in the mid-1960's in China. The emphasis was put on fast reactor neutronics, thermohydraulics, sodium technology, materials, fuels, safety, sodium devices and instrumentation. In 1987, the research turned to applied basic research with the conceptual design of a 60 MW experimental fast reactor as a target. The Project of the China Experimental Fast Reactor(CEFR) with a thermal power 65 MW was launched in 1993. The R&D of fast reactor technology then carried out to serve a design demonstration connected with the different phases of the conceptual, preliminary and detailed design of the CEFR. Recently, three directions of fast rector technology R&D activities have been considered, and some research programs have been developed. They are: (1) R&D related to the CEFR, i.e. experiments to be conducted on the CEFR for its safe operation, (2) R&D related to the projects of a prototype and the demonstration of fast reactors, and(3) advanced SFR technology within the framework of the international cooperation of INPRO and GIF.

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

Drop Performance Test of Conceptually Designed Control Rod Assembly for Prototype Generation IV Sodium-Cooled Fast Reactor

  • Lee, Young-Kyu;Lee, Jae-Han;Kim, Hoe-Woong;Kim, Sung-Kyun;Kim, Jong-Bum
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.855-864
    • /
    • 2017
  • The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

NUMERICAL ANALYSIS OF THERMAL STRATIFICATION IN THE UPPER PLENUM OF THE MONJU FAST REACTOR

  • Choi, Seok-Ki;Lee, Tae-Ho;Kim, Yeong-Il;Hahn, Dohee
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.191-202
    • /
    • 2013
  • A numerical analysis of thermal stratification in the upper plenum of the MONJU fast breeder reactor was performed. Calculations were performed for a 1/6 simplified model of the MONJU reactor using the commercial code, CFX-13. To better resolve the geometrically complex upper core structure of the MONJU reactor, the porous media approach was adopted for the simulation. First, a steady state solution was obtained and the transient solutions were then obtained for the turbine trip test conducted in December 1995. The time dependent inlet conditions for the mass flow rate and temperature were provided by JAEA. Good agreement with the experimental data was observed for steady state solution. The numerical solution of the transient analysis shows the formation of thermal stratification within the upper plenum of the reactor vessel during the turbine trip test. The temporal variations of temperature were predicted accurately by the present method in the initial rapid coastdown period (~300 seconds). However, transient numerical solutions show a faster thermal mixing than that observed in the experiment after the initial coastdown period. A nearly homogenization of the temperature field in the upper plenum is predicted after about 900 seconds, which is a much shorter-term thermal stratification than the experimental data indicates. This discrepancy may be due to the shortcoming of the turbulence models available in the CFX-13 code for a natural convection flow with thermal stratification.

THREE-DIMENSIONAL CORE DESIGN OF A SUPER FAST REACTOR WITH A HIGH POWER DENSITY

  • Cao, Liangzhi;Oka, Yoshiaki;Ishiwatari, Yuki;Ikejiri, Satoshi;Ju, Haitao
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.47-54
    • /
    • 2010
  • The SuperCritical Water-cooled Reactor (SCWR) pursues high power density to reduce its capital cost. The fast spectrum SCWR, called a super fast reactor, can be designed with a higher power density than thermal spectrum SCWR. The mechanism of increasing the average power density of the super fast reactor is studied theoretically and numerically. Some key parameters affecting the average power density, including fuel pin outer diameter, fuel pitch, power peaking factor, and the fraction of seed assemblies, are analyzed and optimized to achieve a more compact core. Based on those sensitivity analyses, a compact super fast reactor is successfully designed with an average power density of 294.8 W/$cm^3$. The core characteristics are analyzed by using three-dimensional neutronics/thermal-hydraulics coupling method. Numerical results show that all of the design criteria and goals are satisfied.

LARGE EDDY SIMULATION OF THERMAL STRIPING IN THE UPPER PLENUM OF FAST REACTOR (대와동모사법을 사용한 고속로 상부플레넘에서의 thermal sriping 해석)

  • Choi, S.K.;Han, J.W.;Kim, D.;Lee, T.H.
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.29-36
    • /
    • 2014
  • A computational study of a thermal striping in the upper plenum of PGSFR(Prototype Generation-IV Sodium-cooled Fast Reactor) being developed at the KAERI(Korea Atomic Energy Research Institute) is presented. The LES(Large Eddy Simulation) approach is employed for the simulation of thermal striping in the upper plenum of the PGSFR. The LES is performed using the WALE (Wall-Adapting Local Eddy-viscosity) model. More than 19.7 million unstructured elements are generated in upper plenum region of the PGSFR using the CFX-Mesh commercial code. The time-averaged velocity components and temperature field in the complicated upper plenum of the PGSFR are presented. The time history of temperature fluctuation at the eight locations of solid walls of UIS(Upper Internal Structure) and IHX(Intermediate Heat eXchanger) are additionally stored. It has been confirmed that the most vulnerable regions to thermal striping are the first plate of UIS. From the temporal variation of temperature at the solid walls, it was possible to find the locations where the thermal stress is large and need to assess whether the solid structures can endure the thermal stress during the reactor life time.

Structural design and integrity evaluations for reactor vessel of PGSFR sodium-cooled fast reactor (PGSFR 소듐냉각고속로 원자로용기 설계 및 구조건전성 평가)

  • Koo, Gyeong Hoi;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.70-77
    • /
    • 2016
  • In this paper, the structural design and integrity evaluations for a reactor vessel of PGSFR sodium-cooled fast reactor(150MWe) are carried out in compliance with ASME BPV III, Division 5 Subsection HB. The reactor vessel is designed with a direct contact of primary sodium coolant to its inner surface and has a double vessel concept enclosing by containment vessel. To assure the structural integrity for 60 years design lifetime and elevated operating temperature of $545^{\circ}C$, which can invoke creep and creep-fatigue damage, the structural integrity evaluations are carried out in compliance with the ASME code rules. The design loads considered in this evaluations are primary loads and operation thermal cycling loads of normal heat-up and cool-down. From the evaluations, the PGSFR reactor vessel satisfies the ASME code limits but it was found that there is a little design margin of creep damage for inner surface at the region of cold pool free surface.

Burnable Absorber Design Study for a Passively-Cooled Molten Salt Fast Reactor

  • Nariratri Nur Aufanni;Eunhyug Lee;Taesuk Oh;Yonghee Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.900-906
    • /
    • 2024
  • The Passively-Cooled Molten Salt Fast Reactor (PMFR) is one of the advanced design concepts of the Molten Salt Fast Reactor (MSFR) which utilizes a natural circulation for the primary loop and aims to attain a long-life operation without any means of fuel reprocessing. For an extended operation period, it is necessary to have enough fissile material, i.e., high excess reactivity, at the onset of operation. Since the PMFR is based on a fast neutron spectrum, direct implementation of a burnable absorber concept for the control of excess reactivity would be ineffective. Therefore, a localized moderator concept that encircles the active core has been envisioned for the PMFR which enables the effective utilization of a burnable absorber to achieve low reactivity swing and long-life operation. The modified PMFR design that incorporates a moderator and burnable absorber is presented, where depletion calculation is performed to estimate the reactor lifetime and reactivity swing to assess the feasibility of the proposed design. All the presented neutronic analysis has been conducted based on the Monte Carlo Serpent2 code with ENDF/B-VII.1 library.

A PRELIMINARY EVALUATION OF UNPROTECTED LOSS-OF-FLOW ACCIDENT FOR A PROTOTYPE FAST-BREEDER REACTOR

  • SUZUKI, TOHRU;TOBITA, YOSHIHARU;KAWADA, KENICHI;TAGAMI, HIROTAKA;SOGABE, JOJI;MATSUBA, KENICHI;ITO, KEI;OHSHIMA, HIROYUKI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.240-252
    • /
    • 2015
  • In the original licensing application for the prototype fast-breeder reactor, MONJU, the event progression during an unprotected loss of flow (ULOF), which is one of the technically inconceivable events postulated beyond design basis, was evaluated. Through this evaluation, it was confirmed that radiological consequences could be suitably limited even if mechanical energy was released. Following the Fukushima-Daiichi accident, a new nuclear safety regulation has become effective in Japan. The conformity of MONJU to this new regulation should hence be investigated. The objectives of the present study are to conduct a preliminary evaluation of ULOF for MONJU, reflecting the knowledge obtained after the original licensing application through CABRI experiments and EAGLE projects, and to gain the prospect of in-vessel retention for the conformity of MONJU to the new regulation. The preliminary evaluation in the present study showed that no significant mechanical energy release would take place, and that thermal failure of the reactor vessel could be avoided by the stable cooling of disrupted-core materials. This result suggests that the prospect of in-vessel retention against ULOF, which lies within the bounds of the original licensing evaluation and conforms to the new nuclear safety regulation, will be gained.