• Title/Summary/Keyword: Fast magnetic resonance imaging

Search Result 134, Processing Time 0.035 seconds

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.165-165
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.138-138
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF

A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

  • Kajan, Zahra Dalili;Khademi, Jalil;Alizadeh, Ahmad;Hemmaty, Yasamin Babaei;Roushan, Zahra Atrkar
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.159-168
    • /
    • 2015
  • Purpose: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. Material and Methods: A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo $T_1$-weighted images, fast spin-echo $T_2$-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. Results: Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. Conclusion: With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

Contrast analysis in the Projection-type fast spin echo imaging in MRI (프로젝션 타입 고속 스핀 에코 자기공명 영상에서의 대조도 분석)

  • Kim, C.Y.;Kim, H.J.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3216-3218
    • /
    • 2000
  • Projection-type Fast Spin Echo (PFSE) imaging has robustness against motion artifacts due to patient motion during magnetic resonance imaging data acquisition, or reduce flow artifacts. However, it has difficulty in controlling T2 contrast. In this paper, T2 contrast in the PFSE method is analyzed. The contrasts in FSE and PFSE method are compared by computer simulation and experiments with volunteers.

  • PDF

The Usefulness of the 3-D Overlapped Reconstruction MR Angiographic Technique in Patients with Hemifacial Spasm - A Preliminary Study (반얼굴 연축 환자에서 삼차원 중첩 자기공명 혈관 조영술 기법의 유용성-초기 보고)

  • Lee, Yoon-Mi;Park, Sun-Won;Pyun, Hae-Wook;Yoon, Myung-Kwan;Kim, Eun-Young;Suh, Chang-Hae;Lim, Myung-Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • Purpose : To investigate the applicability of the new three-dimensional overlapped reconstruction MR angiography (3-D ORMRA) technique in patients with hemifacial spasm and to compare the new 3-D reconstruction images with conventional MRA source images. Materials and Methods : The study group comprised 27 patients with surgically proven hemifacial spasm. In all patients, conventional MRA source images and 3-D fast imaging employing steady-state acquisition (FIESTA) images were obtained prospectively. After 3-D MR angiographic images were obtained, the 3-D MRA and FIESTA images were overlapped at the workstation by using GE A/W 4.2 add/sub software. We analyzed the relationship between the offending vessels and root exit zone of the facial nerve using both 3-D ORMRA images and conventional MRA source images. Results : In 25 of 27 patients, the offending vessel at the REZ of the facial nerve could be correctly identified on conventional MRA source images. In all patients, the presumed offending vessels depicted by the overlapped 3-D reconstruction MRA image corresponded well with the intraoperative findings. The 3-D reconstruction image showed more clear visualization of the spatial relationship between the offending vessels and the root exit zone of the facial nerve. Conclusion : The overlapped 3-D reconstruction MR angiography technique is very useful and informative in patients with hemifacial spasm, as compared with conventional MRA angiography technique.

  • PDF

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver (호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.142-147
    • /
    • 1997
  • Purpose: To compare the effectiveness of the in-phase (IP) sequence and the opposed-phase (Op) sequence in the detection of focal hepatic lesions in the single breath-hold hepatic MR imaging with fast gradient T1-weighted pulse sequences. Materials and Methods: IP and OP T1-weighted breath-hold imaging was performed using fast gradient echo sequences in 45 patients referred for known focal hepatic lesions, in which 78 lesions were detected. Three blind readers independently reviewed the images for lesion detectability. The signal-to-noise ratio (SNR) of the liver, the lesion-to-liver contrast-to-noise ratio (CNR) and the liver-to-spleen CNR were also compared. A consensus was reached by three readers to determine which sequence is better in image quality. Results: On OP images, 61(78%), 61(78%), and 63(89%) lesions were correctly identified for reader 1, 2 and 3, respectively. On IP images, 66(85%), 65(83%), and 65(93%) lesions were detected for each reader, respectively. When two image sets were combined, 71(91 %), 69(88 %), and 76(97%) lesions respectively were detected for each reader. In cases of hepatocellular carcinoma, liver-to-Iesion CNR was greater on the OP images(p (0.05), but in other lesions significant difference was not demonstrated. Liver-to-spleen CNR was higher on OP images(p ( 0.1), but the SNR of the liver was higher on the IP images. Conclusion: Use of both IP and OP imaging can be helpful to avoid erroneous missing of some focal hepatic lesions.

  • PDF

Analysis of Eddy Current Effect in Magnetic Resonance Imaging Using the Finite Element Method (유한요소법에 의한 자기공명영상시스템에서의 와전류 영향 분석)

  • Lee, Jeong-Han;Gang, Hyeon-Su;Jo, Min-Hyeong;Mun, Chi-Ung;Lee, Gang-Seok;Lee, Su-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1999
  • Eddy current in MRI systems degrades gradient field linearity and distorts gradient waveform. When the waveform distortion is spatially variant, it is very difficult to perform special imaging techniques such as the echo planar imaging technique or the fast spin echo imaging technique. In this study, we have developed a new technique to estimate the distorted gradient waveforms at any points inside the imaging region using the finite element method. After obtaining the eddy-current-effect transfer function, which represents magnitude and phase characteristics of the gradient field at a particular point, we have used the transfer function to estimate the actual gradient waveforms at the point. To verify the proposed technique, we have compared the estimated gradient waveforms with the measured ones.

  • PDF

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.