• 제목/요약/키워드: Fast MR imaging

검색결과 110건 처리시간 0.025초

Fast MR Imaging in the Brain

  • 은충기
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 1998년도 제3차 추계학술대회 초록집
    • /
    • pp.105-113
    • /
    • 1998
  • PDF

자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광 (Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy)

  • 문치웅;조경식
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

고속 Spin Echo 자기 공명 영상법에서 두 가지 $T_E$ 영상을 얻기 위한 새로운 방법 (A New Technique or Dual $T_E$ Images Acquisition in Fast Spin Echo MR Imaging)

  • 조민형;이수열;문치웅;조현화;이완
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.294-298
    • /
    • 1997
  • In the magnetic resonance imaging, the fast spin echo imaging technique is a widely used clinical imaging method, since its scanning time is much shorter than the conventional spin echo imaging and it gives the almost same image quality. However, the fast spin echo technique has two times longer imaging time or the dual echo acquisition which can obtain a spin density image and a $T_2$-weighted image simultaneously. To overcome such a drawback, this paper proposes a new fast dual echo imaging technique which can give the same quality images at the single echo imaging time. The proposed technique reduces the imaging time by overlapping most of echo train data for each image reconstruction. In order to verify its validity and usability the human head experimental results which were obtained at the 0.3T permanent MRI system are presented.

  • PDF

고속 Burst 영상법 - pulse sequence 중심으로 (Fast Burt Imaging)

  • 강호경;노용만
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권1호
    • /
    • pp.13-19
    • /
    • 1999
  • MRI imaging provides many benefits such as noninvasive, 3-dimensional imaging capabilities. But it has relatively serious drawback that is the long data collection time, compared with other imaging modality. Many studies have been performed for fast MR imaging. But EPI and SEPI (4-6) are required to expensive hardware. In this paper, we introduce to Burst imaging technique. It can reduce imaging time by use of a mulitple RF excitation technique. Further it is easily implemented to the normal MRI system. But a pixel profile in the conventional burst sequence is so poor that excited area by burst sequence is a small portion of a pixel. This causes poor signal to noise ratio in burst image. therefore frequency sweeping of RF pulse for burst imaging sequence is proposed to improve pixel profile. A burst pulse train is shaped by liner or nonlinear frequency sweeping function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on how frequency sweep is made. Computer simulations with Bloch equation and experimental results obtained using a 1.0 T NMR imaging system are presented.

  • PDF

진단용 자기공명영상장치의 삽입 코일에 관한 연구 (A Study on the Insertional Coil of MRI Device for Diagnosis)

  • 이용문;임근호;서대건;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.33-37
    • /
    • 2003
  • Endovaginal and endorectal receiver only surface coil were designed for MR imaging(MRI) and $^1H$ MR spectroscopy(MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round comer. The shape of endorectal coil wire was long elliptic shape during insertion and circular shape after insertion. Conventional spin echo and fast spin echo sequences were used as T1 and T2 weighted imaging sequences, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method. Using home-built endvaginal and endorectal coils, excellent T1 and T2 images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo $^1H$ MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Diagnosis of Subclavian Steal: Contrast Enhanced 3D MR Angiography vs 2D TOF

  • 이호규;김건언;최중곤;서대철
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.136-136
    • /
    • 2001
  • Purpose: Subclavian steal refers to the retrograde flow of blood in a vertebral artery that supplies t ipsilateral shoulder and arm caused by proximal subclavian artery stenosis or occlusion. T purpose of this exhibit is to demonstrate MR findings of subclavian steal on contrast-enhanc 3D (CE 3DMRA) and 2D TOF MR angiography. Method: Four patients(men 3 and women 1, age: 28-78years) with subclavian steal obtained both CE 3DMRA and digital subtraction angiography(DSA) including subclavian arterie Sequential imaging was undertaken during first pass after double dose of Gd-DTPA (0 mM/kg) Injected by a power injector. Coronal source images were obtained with coronal D-fast low angle shot sequence(TR/TE/flip angle=3.8/l.3/35, acquisition time= 10sec/one measurement). Precontrast imaging was subtracted from enhanced images and maximu intensity projection was done. 2D time-of-flight MR angiography(2D TOF) of the carot bifurcation was added in all cases with post-saturation. All studies were review retrospectively.

  • PDF

1.5Tesla and 3.0Tesla에서 관류 MR의 소리 스펙트럼 분석 (Comparison with 1.5Tesla and 3.0Tesla of Acoustic Noise Spectrum of DWI MR Pulse Sequence)

  • 권대철;최지원
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.491-496
    • /
    • 2018
  • 1.5Tesla와 3.0Tesla의 MRI 검사의 DWI (diffusion-weighted imaging) 펄스시퀀스에서 노이즈 스펙트럼을 분석하여 MRI검사의 기초자료를 제공하여 임상에서 적용하는데 목적이 있다. MRI 검사에서 ACR (American College of Radiology) 팬텀과 노이즈 스펙트럼은 Wavepad sound editor version 8.13 (NCH software, Green wood Village, CO, USA)로 FFT (fast Fourier transform), TFFT (time based fast Fourier transform)를 분석하였다. MR 1.5Tesla와 3.0Tesla의 DWI 펄스 시퀀스에서 검사실에 따른 노이즈 스펙트럼 및 FFT와 TFFT를 분석하였다. 1.5Tesla에 비해 3.0Tesla에서 FFT 및 TFFT에서 주파수 진폭의 노이즈 임계값은 1.5Tesla에서 -6 dB 사이였고, 3.0Tesla에서는 0 dB 사이로 분석되어 환자의 소음감소를 위한 DWI 펄스시퀀스를 환자에게 적절하게 임상에서 적용할 필요가 있다.

호흡정지 T1 강조 간 자기공명영상에서 동위상 역위상 FMPSPGR 영상의 비교 (Comparison of In-Phase and Opposed-Phase FMPSPGR Images in Breath-hold T1-weighted MR IMaging of Liver)

  • 김명진;김만득;정재준;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.142-147
    • /
    • 1997
  • 목적: 호흡정지 간 자기공영상에서 국소 간 병변을 발견함에 있어 동위상(inphase) 방식과 역위상(opposed-phase) 방식의 fast multiplanar spoiled gradient recalled(FMPSPGR) 영상간의 효율성을 비교하고자 하였다. 대상 및 방법: 다른 검사를 통해 국소 간 병변이 발견되었거나 의심되었던 45명의 환자의 78개의 병변에 대한 고속경사에코대열의 동위상과 역위상 영상을 비교하였다. 병변 발견률을 평가하기 위해 세 명의 사전 정보 없는 판독의가 독립적으로 영상을 검토하였다. 간의 신호대잡음비, 병변과 간의 대조대잡음비 및 간과 비장 간 대조대잡음비를 비교하였다. 세 명의 동의에 의해 어느 대열에서 영상의 질이 더 나은지 결정하였다. 결과: 역위상 영상에서 판독의 1, 2, 3이 각각 61(78%), 61(78%), 및 63(89%)개의 병변을 정확히 발견하였다. 동위상 영상에서 각 판독의가 66(85%), 65(83%) 및 65(93%)개의 병변을 발견하였다. 두 영상을 조합하였을 때, 71(91%), 69(88%) 및 76(97%)개의 병변이 각각 발견되었다. 간세포암이 증례에서 간-병변간 대조대잡음비는 역위상 영상에서 더 컸으나(p<0.05), 다른 병변에서의 의미 있는 차이는 보이지 않았다. 간-비장간 대조잡음비는 역위상 영상에서 높았으나(p<0.1), 간의 신호대잡음비는 동위상 영상에서 더 높았다. 결론: 국소적 간 병변을 놓치지 않고 발견 하기 위새서는 동위상 영상과 역위상 영상을 모두 이용하는 것이 바람직하다.

  • PDF