• Title/Summary/Keyword: Fan heater

Search Result 59, Processing Time 0.022 seconds

A CASE STUDY ON DEVELOPING A DESIGN OF OIL FAN HEATER - With a focus on '92 GoldStar Co Oil fan heater - (석유 팬 히터 디자인 개발 사례 연구 - '92금성사 석유팬 히터를 중심으로 -)

  • 오성진
    • Archives of design research
    • /
    • v.6 no.1
    • /
    • pp.47-72
    • /
    • 1993
  • Nowadays conmpetltlOn of developing new products is getting keen. We can notice that the role and importance of design are emphasized more than ever.The main cause of this tendency is that technical power is no more a factor which secures the superiority in products competition, as technology is gneneralized in the world. Therefore, design is recognized intensely as a competitive strategy to promote competitive power of products. It is an already known fact that the design for both rational function and charming form to satisfy consumer's desires is a short cut to success, when a company develops a new product to promote competitive power in market. The design which plays a leading role in the activity of developing more cnovenient, more economical and more aesthetic products is called 'Competitive Edge' or 'New Corporate Weapon'. Judging form each company's case of developing products, we can guess that it has its own plan and process of developing new products with defferdnl interest and effort. The strategy of developing products is considered as the most important factor that affects the very existence of rhe company. This thesis is composed of six chapters in all. In the firstchapter, I describe the purpose, method, and scope of study.The second chapter includes the image of form in oil fan heater market in nearby Japan and that of interior in our domestic home and shops, and the trend of word life cycle by analyzing circumstances. The third chapter focuses on consumer's attitude. In the fourth chapter, I compare and test current products of competitive companies including Samsung, Daewoo, Shinilwith those of Gold STar. The trend of products, technique, and design which resulted form this comparison is described. In the fifth chapter I explain the strategy, and process of design of oil fan heater in 1992. The last conclusive chapter presents the major point drawed form the case study, but not includes an estimation of products and the condition of market. In this thesis, I reconsider the general understanding of design and designing process and the value of design as a main factor in the strategy of management by investigating the development of products and the strategy of design, and the process of design.

  • PDF

Fan and Heater Management Schemes for Layer Filling and Mixing Drying of Rough Rice with Natural Air by Simulation (시뮬레이션에 의한 벼의 누적혼합 상온통풍건조의 송풍기 및 가열기의 운영방법에 관한 연구)

  • 금동혁;한충수;박춘우
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.229-244
    • /
    • 1998
  • This study was performed to determine proper fan and heater management schemes for natural air drying of rough rice in round steel bin with stirring device under Korean weather conditions. A computer simulation model was developed to predict moisture content changes, energy requirements, and drymatter losses during drying of rough rice by natural air. Drying test was conducted to validate the simulation model using round steel bin of holding capacity of 300ton at Rice Processing Complex in Jincheon. The bin was filled with rough rice every day and mixing by stirring device. Moisture contents, ambient air temperatures, relative humidities, static pressures in plenum chamber in the bin, airflow rates, and electrical and fuel energy were measured. Relative errors of moisture content changes predicted by the simulation model were below 5ft, and relative errors of final moisture content, final grain weight, required energy ranged from 0.9% to 6%. These not levels indicated that the simulation model can satisfactorily predict the performance factors of natural air drying system such as drying rates and energr consumptions comparing error level of 10% to 15% in other drying simulation models generally used in dryer desists. Twelve different fan and heater management schemes were evaluated using the computer simulation model based on three hourly weather data from Suweon for the period of 1952-1994. The best management schemes were selected comparing the drymatter losses, required drying times, required energy consumptions. Operating fan without heating only when ambient relative humidity was below 85% or 90% appeared to be the most effective method of In operation in favorable drying weather. Under adverse drying climates or to reduce required drying time, operating fan continuously, and heating air with $1.5^{\circ}C$ temperature rise only when ambient relative humidity was over 85% appeared to be the most suitable method.

  • PDF

A Study on Risk Analysis and Acident Prevention Heater Interlock By-pass (Heater interlock by-pass로 인한 위험분석 및 사고방지에 대한 연구)

  • Son Jae-geun;Park Kyo-Shik;Kang Tae-Yeon;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper it was investigated 15 heaters of CDU plant heater, NCC plant heater, CO plant heater, Aromatic plant heater and so on while running in our country. It was also analysed the standard of operation procedure, the action in alarm, the interlock system, the operating situation of the interlock by-pass and major accident about the heater and so on. This paper presents the installation of the on-line monitoring, the additional installation of the local pressure gauge and temperature gauge, the check in starting operation,'the management of the interlock by-pass, the change of manufacturer causing the disorder of instrument sensor, the management method of DCS alarm for methods of the interlock prevention and facilities improvement. It was few information about the heater interlock in the inside and outside of the country We mainly have studied with reflecting the opinion of the operator and manager on site, the sheet of process trouble and operation procedure and so on. we think that the accident relating to the interlock will significantly reduce if the companies apply the conclusion of this study(i.e. methods of the interlock prevention and facilities improvement).

  • PDF

Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant (대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정)

  • Park, Kun Woo;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.39-44
    • /
    • 2018
  • In this study, I analyzed the effects on stabilizing the draft system, boiler efficiency when changing excess air ratio under 870 MW load limit operation condition in a large capacity coal fired power plant and decided optimum excess air ratio. It is positively necessary to choose adequate excess air ratio for stabilizing draft system because air pre-heater pressure drop and induced draft fan first stall margin are changing when adjusting excess air ratio. This study therefore, measured air pre-heater pressure drop, induced draft fan first stall margin, boiler efficiency, loss and has chosen adequate excess air ratio adjusting excess air ratio from 1.153 to 1.127. So it is recommended that the operation point needs to be changed to 1.127 that is not only to decrease air pre-heater pressure drop and to stabilize draft system and to secure stall margin but also to maintain boiler efficiency to equivalent level.

  • PDF

Experimental Study on the Development of Food Drying Machine for Home Use Using Low Electricity (저전력 가정용 식품건조기 개발에 관한 실험적 연구)

  • Kim, Soon-Ho;Kim, Ki-Wan;Kim, Hoon
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.43-49
    • /
    • 2015
  • This study has been analyzed and investigated the possibility for the substitution of a heat source with the application of PTC(Positive Temperature Coefficient Heater) in a food drying machine. And this experiment was conducted to measure temperatures at the upper part of the vessel and the heat sink. And the structure has the many holes plane connected with the external air in the upper part of similar volumetric vessel, and attached to the PTC heater (3sets) of total consumption electricity of 120[W] in Al radiant heat structure and the small fan (2sets) in the suitable space of the lower part. Consequently, it was found that at the most conditions of food drying test with the seven holes(5mm) under the control temperature $62^{\circ}C$, the optimum drying condition formatted and the optimum time range especially appeared from 6,500 second to 7,000 second in case of drying test on banana sample.

Development of an Integrated Controller to the Control Vertical Agitation Heater and Facilities (수직교반히터 및 시설물 제어를 위한 통합 제어기 개발)

  • Kim, Jin-Ha;Yoo, Seung-Hyeok;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.4
    • /
    • pp.753-758
    • /
    • 2020
  • In this paper, we intend to develop a control system that can apply the developed vertical stirring heater to the facility house and control the other facilities (circulating fan, ventilation fan, window using a switching motor, ceiling, and dehumidification). Through this, it is intended to increase the cultivation efficiency of crops and improve storage environment of crops held by non-heated storage or storage warehouses to increase the storage period and freshness. In addition, ICT monitoring technology is added to enable users to easily solve problems when there is a problem due to changes in the cultivation and storage environment with Real Time Control (RTC).

Numerical Experiments for the Optimization of the Flow Path through a Cross-Flow Fan (횡류팬 유로최적화를 위한 수치실험)

  • Jun, Yong-Du;Lee, Jong-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.147-151
    • /
    • 2002
  • Cross flow fan system is widely used for various applications, especially for the air-moving device of heaters, air-conditioners, and air-curtains. Although there are efforts for the optimization of cross-flow fan flow path with different methods of approach, it is still being investigated by many researchers through experimentally and/or theoretically, because the flow pattern of the cross flow fan is not stereotyped. This paper presents some results from numerical experiments for the optimization of the flow path through a cross-flow fan to be applied to indoor wall-mounted room heater. Two dimensional analysis has been applied to a specific fan system including inlet and diffuser outlet. Flow characteristics art presented and discussed for two different flow path at three different operating conditions represented by rotational speed(800, 1,000, 1,200 rpm) of the In. According to the simulated results for the specific fan system under consideration, it could be found that the flow pattern resembles each other at different rotational speed (to say from 800 rpm to 1,200 rpm) for a fixed flow path, while the secondary flows mostly absorbs the speed effects. By changing the flow path significant increase in volume flow rate is estimated upto 2.65 at the same rotational speed. According to the present experience, fan flow path design can be performed more efficiently by incorporating this type of numerical experiments combined with the model tests.

  • PDF

Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater (온풍난방기의 열효율 증대를 위한 열교환기 구조개선)

  • Kang, Geum-Choon;Kang, Yoen-Ku;Ryou, Young-Sun;Kim, Young-Joong;Lee, Si-Young;Paek, Yee
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

Heat Transfer from a Fan-Aluminum Foam Heat Sink Assembly for CPU Cooling (CPU 냉각을 위한 홴-발포알루미늄 방열기 조합의 열전달 특성)

  • Kim, Seo-Yeong;Lee, Myeong-Ho;Baek, Jin-Uk;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.417-422
    • /
    • 2002
  • The experiments have been carried out to evaluate the cooling performance of a fan-aluminum foam heat sink assembly in comparison with a conventional CPU cooler. In terms of the dimensionless surface temperature of the heater, the cooling performance of the aluminum foam heat sink is similar to that of the conventional one with much reduced weight. The optimum fin height is found to be strongly dependent on the fin height of the heat sink and flow characteristics of the cooling fan.

A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer (Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究))

  • Suh, W.M.;Min, Y.B.;Yoon, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF