• 제목/요약/키워드: Fan Efficiency

검색결과 441건 처리시간 0.029초

Experimental and Simulation Study of PEMFC based on Ammonia Decomposition Gas as Fuel

  • Zhao, Jian Feng;Liang, Yi Fan;Liang, Qian Chaos;Li, Meng Jie;Hu, Jin Yi
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.63-70
    • /
    • 2022
  • Compared with hydrogen, ammonia has the advantages of high gravimetric hydrogen densities (17.8 wt.%), ease of storage and transportation as a chemical hydrogen storage medium, while its application in small-scale on-site hydrogen production scenarios is limited by the need for complex separation equipment during high purity hydrogen production. Therefore, the study of PEMFC, which can directly utilize ammonia decomposition gas, can greatly expand the application of fuel cells. In this paper, the output characteristics, fuel efficiency and the variation trend of hydrogen concentration and local current density in the anode channel of fuel cell with the output voltage of PEMFC fueled by ammonia decomposition gas were studied by experiment and simulation. The results indicate that the maximum output power of the hybrid fuel decreases by 9.6% compared with that of the pure hydrogen fuel at the same inlet hydrogen equivalent. When the molar concentration of hydrogen in the anode channel is less than 0.12, the output characteristics of PEMFC will be seriously affected. Employing ammonia decomposition gas as fuel, the efficiency corresponding to the maximum output power of PEMFC is approximately 47%, which is 10% lower than the maximum efficiency of pure hydrogen.

고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구 (A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository)

  • 황인필;최희주;노장훈;김진
    • 터널과지하공간
    • /
    • 제22권3호
    • /
    • pp.173-180
    • /
    • 2012
  • 본 연구에서는 방사성 폐기물 처분장 설계 시 필요할 수 있는 공기 유동 방향의 제어에 이점을 가진 Diagonal 환기 회로에 대해서 연구하였다. 연구 결과, Diagonal 환기 회로에서도 Diagonal 갱도(Branch)로 유입시킬 공기량과 공기 유동 방향을 미리 정한다면 다른 직 병렬 회로와 마찬가지로 수식이나 프로그램에 의한 공기량을 산정할 수 있음을 알 수 있었다. 이를 적용하기 위해 앞으로 처분될 고준위 방사성 폐기물의 추정 데이터를 통해 Diagonal 환기 회로와 병렬식 환기 회로가 적용된 고준위 방사성 폐기물 처분장의 설계안을 마련하였다. 마련된 설계안 별 비교 및 예상 운영 결과를 얻기 위해서 환기 네트워킹 프로그램인 Ventsim 프로그램을 통해 환기 네트워크 시뮬레이션을 수행하였다. 그 결과 저항 증가가 큰 수치로 발생할 것으로 예상되었던 Diagonal 처분장은 병렬식 환기 회로가 적용된 처분장과 비교하였을 때, 팬 압력은 1570 pa, 총 유량 84 $m^3/s$, 팬 효율 76.4%, 팬 소요 전력 181.2 kW 및 연간 팬 운영 비용 178,710,838원으로 압력과 유량값에서 최대 8% 정도의 차이를 보였고, 운영 비용 측면에서는 1.5%의 차이를 보였다.

Recent Development of P-Tunnel Oxide Passivated Contact Solar Cells

  • Yang Zhao;Muhammad Quddamah Khokhar;Hasnain Yousuf;Xinyi Fan;Seungyong Han;Youngkuk Kim;Suresh Kumar Dhungel;Junsin Yi
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.332-340
    • /
    • 2023
  • Crystalline silicon solar cells have attracted great attention for their various advantages, such as the availability of raw materials, high-efficiency potential, and well-established processing sequence. Tunnel oxide passivated contact (TOPCon) solar cells are widely regarded as one of the most prospective candidates for the next generation of high-performance solar cells because an efficiency of 26% has been achieved in small-area solar cells. Compared to n-type TOPCon solar cells, the photo conversion efficiency (PCE) of p-type TOPCon is slightly higher. The highest PCEs of p-type TOPCon and n-type TOPCon solar cells are 26.0% and 25.8%, respectively. Despite the highest efficiency in small-area cells, limited progress has been achieved in p-type TOPCon solar cells for large are due to their lower carrier lifetime and inferior surface passivation with the boron-doped c-Si wafer. Nevertheless, it is of great importance to promoting the p-type TOPCon technology due to its lower price and well-established manufacturing procedures with slight modifications in the PERC solar cells production lines. The progress in different approaches to increase the efficiencies of p-type TOPCon solar cells has been reported in this review article and is expected to set valuable strategies to promote the passivation technology of p-type TOPCon, which could further increase the efficiency of TOPCon solar cells.

유리온실의 태양열 집열방법별 집열효과 (Heating Efficiency of Difference Heat Collection Methods for Greenhouse)

  • 최영하;이재한;권준국;박동금;이한철
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.166-170
    • /
    • 2000
  • 자연열(태양열)을 효율적으로 이용하기위해 1999년부터 2000년 까지 2년간 상면적이 100$m^2$인 3동의 유리온실에 각기 다른 집열시스템을 설치하였다. 즉, 집열면적과 경사도가 각각 24$m^2$, 50$^{\circ}$로서 현재 시판되고 있는 태양열 집열기(평판형, Solar hart Inc.)를 이용하는 방법, 직경과 송풍량이 각각 1m, 2.5m$^{-3}$.m$^{-2}$ .min로서 라디에이터가 부착된 2개의 유동팬을 천장부에 설치하고 천창을 밀폐한 후 온실상부의 열을 집열하는 방법, 온실의 중도리 전부를 물이 순환되는 각관 (75x45x3t, 1m 간격x10줄x온실길이 12m=120m)으로 설치하여 집열하는 방법 등으로 하였다. 각 동마다 지하에 26톤의 저수 능력을 갖는 D2000xW1500xL8600의 축열조를 설치한 후 중간을 막아 저온수조와 고온수조로 구분하였고, 수조 중간 1.5m 높이에 통수로를 내어 일정량의 물(약 15톤)이 지속적으로 순화될 수 있도록 하였다. 최저기온 9$^{\circ}C$로 설정하여 1,000$m^2$를 공간 난방할 경우 난방연료 절감율은 태양열 집열기, 유동팬 및 각관에서 각각 7%, 19%, 28%로 나타났다. 태양열 집열기를 이용하는 대부분의 농가에서는 40~50$m^2$ 정도의 집열면적을 갖는 집열기를 이용하고 있는데 이 경우 년간 난방연료 절감율은 14% 정도로서 경제성이 없으며, 유동팬도 집열효율에 비해 제작, 설치 및 유지비가 과다하게 소요되므로 경제성이 없다. 각관의 경우 관 자체의 자재비나 설치비에 추가부담이 적으면서 집열효율이 비교적 높기 때문에 관의 부식, 골조 표면적 증가에 의한 시설내 차광 증가, 중도리의 각형 구조로 인한 강도저하 등의 문제가 해결되면 집열 방법으로 고려될 수 있을 것이다.

  • PDF

온풍난방기의 열효율 증대를 위한 열교환기 구조개선 (Mechanism Improvement of the Heat Exchanger for the Thermal Efficiency Increase of Hot Air Heater)

  • 강금춘;강연구;유영선;김영중;이시영;백이
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.363-370
    • /
    • 2009
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. Hot air heaters of 256,246 units have been supplied as main greenhouse heating equipment until 2008 and greenhouse heating cost has reached to 620 billions won in Korea. In order to improve the thermal efficiency of the hot air heater and to reduce the expenses for greenhouse heating, prototype hot air heater was manufactured and tested in this experiment. The heat exchanger of tested prototype hot air heater was circular and hexagonal pipe type and inline and stagger arrangement type. Capacity of the heating was 43,062 kJ/h and total heat transfer area of the heat exchanger was $10.728\;m^2$. According to the performance test, it could supply heat of 38,240 to 35,100 kJ/h depending on the fan motor speed of 1,740~1,220 rpm, respectively. Thermal efficiency of hot air heater was 87.0% to 80.8% in the same conditions. As a result, thermal efficiency of hot air heater with hexagonal pipe-stagger arrangement heat exchanger developed in this study was higher 10.2% than that of conventional hot air heater and heating energy saving rate of 14.3% increased.

A dominant vibration mode-based scalar ground motion intensity measure for single-layer reticulated domes

  • Zhong, Jie;Zhi, Xudong;Fan, Feng
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.245-264
    • /
    • 2016
  • A suitable ground motion intensity measure (IM) plays a crucial role in the seismic performance assessment of a structure. In this paper, we introduce a scalar IM for use in evaluating the seismic response of single-layer reticulated domes. This IM is defined as the weighted geometric mean of the spectral acceleration ordinates at the periods of the dominant vibration modes of the structure considered, and the modal strain energy ratio of each dominant vibration mode is the corresponding weight. Its applicability and superiority to 11 other existing IMs are firstly investigated in terms of correlation with the nonlinear seismic response, efficiency and sufficiency using the results of incremental dynamic analyses which are performed for a typical single-layer reticulated dome. The hazard computability of this newly proposed IM is also briefly discussed and illustrated. A conclusion is drawn that this dominant vibration mode-based scalar IM has the characteristics of strong correlation, high efficiency, good sufficiency as well as hazard computability, and thereby is appropriate for use in the prediction of seismic response of single-layer reticulated domes.

지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가 (Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System)

  • 박시삼;나상민;박종헌;이건중;김태원;김승엽
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

국내 아파트의 미세먼지 유입 특성 (Infiltration Characteristics of Particulate Matter at a Korean Apartment House)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제15권4호
    • /
    • pp.149-157
    • /
    • 2019
  • Infiltration characteristics of airborne particulate matter had been investigated in real-life for about 90 days over 2 years in a Korean apartment building where a 3-person household had lived and the exclusive private area was 84.9 ㎡. Airtightness was measured by fan depressurization, and the ACH50 was 2.41 times per hour. In and outdoor particle concentrations were measured by optical particle counters. Infiltration factors and filtration efficiencies of the house, which reflect the removal of outdoor particles penetrating building envelope and the deposition inside a building, were obtained from data screened based on an empirical evaluation process. Infiltration factor of fine particles showed a range from about 42% at 0.4 m/s of wind speed to 72% at 4.2 m/s of wind speed with closed windows and doors. Filtration efficiency was like a MERV 13 grade filter with an open window outside at a balcony at low outdoor wind speed under 1 m/s. The grade decreased to MERV 11 by opening another outside window at the other balcony. Filtration efficiencies decreased as much as 29% in average at a range of 0.3~2.5 ㎛.

높이 축소형 고효율 냉각모듈의 성능 평가에 관한 연구 (Studies on the Performance Evaluation of Downsized High-efficiency Cooling Module)

  • 정정훈;신윤혁;박성욱;정순안;김성철
    • 한국자동차공학회논문집
    • /
    • 제19권6호
    • /
    • pp.61-67
    • /
    • 2011
  • The cooling module needs enough space (or distance) from hood to absorb the energy from any pedestrian collision. Downsized cooling module for pedestrian protection is important to reduce the severity of pedestrian injury. When a vehicle collision happens, the downsized cooling module is required to reduce the risk of injury to the upper legs of adults and the heads of children. In this study, the performance of cooling module to cool the engine was investigated under 25% height reduction. The heat dissipation and pressure drop characteristics have been experimentally studied with the variation of coolant flow rate, air inlet velocity and A/C operation ON/OFF for the downsized cooling module. The results indicated that the cooling performance was about 94% level compared to that of the conventional cooling module. Therefore, we checked that the cooling module had good performance, and expected that the cooling module could meet the same cooling performance as conventional cooling module through optimization of components efficiency.

부속구를 부착한 슬롯 만곡형전개판의 성능에 관한 모형실험 (Model Test on the Three-Slot Cambered Otter Board with Accessories)

  • 권병국;고관서
    • 수산해양기술연구
    • /
    • 제30권2호
    • /
    • pp.71-77
    • /
    • 1994
  • A serious of study is carried out to practical use of the three-slot cambered otter board improved by the authors. As the first step, we designed main plates, slots and accessories, such as holding plate, fan-shaped towing plate, normans, center ring, etc. Standing on this design, we made the simple cambered and three-slot cambered model otter board with accessories in a linear scale 6:1. and carried out model test to examine the efficiency of these boards. The obtained results can be summarized as follows: 1. On the simple cambered board with accessories, the values of the maximum shear coefficient($C _{LX}$ ). drag coefficient(($C _{D}$) and hydrodynamic efficiency($C _{L}$/$C _{D}$ ) are 1.39, 0.56, 2.48 at $22^{\circ}$ of the angle of stall respectively. 2. On the three-slot cambered board with accessories, $C _{LX}$/$C _{D}$ and $C _{I}$/$C _{D}$ are 1.67, 0.92, 1.82 at $32^{\circ}$ of the angle of stall respectively. 3.$C _{LX}$ of board with accessories is smaller 10~12% than that of only the main plate, and the angle of stall is almost same. 4. $C _{LX}$ and the angle of stall of the three-slot cambered board with accessories are greater 20% and $10^{\circ}$ than that of the simple cambered board respectively.

  • PDF