• Title/Summary/Keyword: False-negative results

Search Result 302, Processing Time 0.022 seconds

Comparison of Acid-Fast Staining, PCR, LCR, PCR-Hybridization for Detection of Mycobacterum Tuberculosis in Clinical Specimens (임상 검체에서 결핵균 검출을 위한 항산성염색, PCR, LCR, PCR-Hybridization 검사법 간의 비교)

  • Choi, Jong-Rak;Lim, Jong-Baeck;Kim, Hyung-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.281-289
    • /
    • 2000
  • Background : Mycobacterial culture is a confirmatory test to detect. M. tuberculosis, but it takes at least 6 weeks to diagnose. PCR is a rapid and sensitive method, but it is known that PCR has a high false positive rate due to contamination, and a high false negative rate due to inhibitors. It is also known that LCR and PCR-Hybridization, recently developed methods, are more specific methods than PCR in terms of detecting M. tuberculosis. In this study, we estimated the clinical utility of in house PCR, LCR and PCR-Hybridization for the detection of M. tuberculosis. Methods : We evaluated 75 specimens, upon which M. tuberculosis culture based testing was requested, by PCR LCR, and PCR-Hybridization and compared results. Mycobacterial culture was performed on 3% Ogawa media for 8 weeks, and an in house PCR, LCx Mycobacterium tuberculosis assay kit (Abbott Laboratories, North Chicago, III) and the AMPLICOR M. tuberculosis test kit (Roche Molecular Systems, Inc. Branchburg, NJ. USA). Results : In the view of the culture results, the sensitivities of the three tests were 40%, 80%, and 100% and their specificities were 98.6%, 94.3%, and 94.3%. Conclusion : LCR and PCR-Hybridization are rapid and sensitive methods for detecting M. tuberculosis in clinical laboratories.

  • PDF

Consideration About the Bacterial Endotoxin Test Showing False Positive Test Result When Performing LAL Test (LAL Test에서 위양성을 나타내는 원인들에 대한 고찰)

  • Hwang, Ki-Young;Cho, Yong-Hyun;Lee, Yong-Suk;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.156-158
    • /
    • 2009
  • Purpose: Since radiopharmaceuticals are intended for human administration, it is imperative that we should undergo quality control very strictly. Now almost all the PET laboratories have adopted Bacterial Endotoxin Test as the stand quality control method to monitor whether pyrogen is free or not in the product vial containing crude solution. The aim of this study is to find out the reason why false positive result is observed when using commercially available test vial. Materials and Methods: For this experiment, we used commercially available single test kit (Associates of Cape Code. Inc. USA) and we made pH samples by mixing each buffer whose pH ranges are 1.0 to 12.0. Otherwise we made Ethanol samples diluted with distilled water. After making test samples, it added 0.2 mL to the test vial. Assay mixture in the test vial was incubated in a water bath (Chang Shin Co. KOR) for 60 min at $35{\pm}2^{\circ}C$. Results: After incubation period ($60{\pm}1^{\circ}C$), we inverted the test vial about $180^{\circ}$ To know what pH and how many percentage of Ethanol (Fisher Scientific Korea. Ltd) will affect the reaction. With pH buffer, false positive result was observed at pH 1.0 to 5.0 and 7.7 to 12.6 but at pH 5.2 to.7.5, the test results show negative. It's very strange that we couldn't observe negative test result with Tris buffer at pH 8.4, 8.6, 8.8, 9.0. in other case Ethanol, the test result was seen with 5 to 10% Ethanol. But to my surprise we could see very thick gel formation with 100% Ethanol. Conclusions: In this study, we could notice that pH which is too much acidic or alkalic or high concentrated Ethanol would affect Bacterial Endotoxin Test result. As you know, LAL test is sensitive and very reliable method. Therefore, we are needed to elicit the accurate test result as possible as we can.

  • PDF

Usefulness of FDG-PET/CT as a Diagnostic Tool for Routine Post Therapy Evaluation in Endometrial Cancer (자궁내막암의 치료 후 루틴 추적검사 방법으로서 FDG-PET/CT의 유용성)

  • Lee, Shin-Jae;Jeon, Tae-Joo;Kim, Seung-Jo;Kim, Hee-Jin;An, Hee-Jung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.301-308
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the usefulness of FDG-PET/CT as follow up imaging tool in patients with endometrial cancer after therapy. Material and Methods: One hundred one patients with endometrial cancer who underwent FDG PET/CT after the treatment of this disease were included in this study population (25-79 yr old, Mean age 50.6 yr old) and all these patients also performed various laboratory and imaging studies such as serum tumor marker, CT or MRI. The lesions having increased focal FDG uptake were classified into benign, equivocal, and malignant one according to their pattern and activity. Tumor recurrence was confirmed by histopathological results and other clinical and imaging data. Results: Among the 19 patients with 30 malignant or equivocal hot uptakes, 11 of 14 patients supposed to be malignant finding in PET/CT were proved to be tumor recurrence, while one of 5 patients with equivocal lesions were recurred malignancy, Two false negative cases were turned out to be peritoneal carcinomatosis, Estimated sensitivity, specificity and accuracy of PET/CT for diagnosis of recurrence in endometrial carcinoma after treatment were 86 %, 92 % and 91 %, respectively. Positive and negative predictive values in the same issue were 63% and 98%, respectively. Conclusion: FDG-PET/CT is useful for regular work up of endometrial carcinoma after the treatment because of its high negative predictive value as well as high sensitivity and specificity.

Noninvasive prenatal test for fetal chromosomal aneuploidies by massively parallel sequencing of cell-free fetal DNA in maternal plasma: The first clinical experience in Korea

  • Han, Sung-Hee;Yang, Young-Ho;Ryu, Jae-Song;Kang, Myung-Soo;Kim, Young-Jin;Lee, Kyoung-Ryul
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • Purpose: Noninvasive prenatal test (NIPT) by massively parallel sequencing (MPS) of cell-free fetal DNA in maternal plasma marks a significant advancement in prenatal screening, minimizing the need for invasive testing of fetal chromosomal aneuploidies. Here, we report the initial clinical performance of NIPT in Korean pregnant women. Materials and Methods: MPS-based NIPT was performed on 910 cases; 5 mL blood samples were collected and sequenced in the Shenzhen BGI Genomic Laboratory to identify aneuploidies. The risk of fetal aneuploidy was determined by L-score and t-score, and classified as high or low. The NIPT results were validated by karyotyping for the high-risk cases and neonatal follow-up for low-risk cases. Results: NIPT was mainly requested for two clinical indications: abnormal biochemical serum-screening result (54.3%) and advanced maternal age (31.4%). Among 494 cases with abnormal biochemical serum-screening results, NIPT detected only 9 (1.8%) high-risk cases. Sixteen cases (1.8%) of 910 had a high risk for aneuploidy: 8 for trisomy 21, 2 for trisomy 18, 1 for trisomy 13, and 5 for sex chromosome abnormalities. Amniocentesis was performed for 7 of these cases (43.8%). In the karyotyping and neonatal data, no false positive or negative results were observed in our study. Conclusion: MPS-based NIPT detects fetal chromosomal aneuploidies with high accuracy. Introduction of NIPT as into clinical settings could prevent about 98% of unnecessary invasive diagnostic procedures.

Analysis of online parenting community posts on expanded newborn screening for metabolic disorders using topic modeling: a quantitative content analysis (토픽 모델링을 활용한 광범위 선천성 대사이상 신생아 선별검사 관련 온라인 육아 커뮤니티 게시 글 분석: 계량적 내용분석 연구)

  • Myeong Seon Lee;Hyun-Sook Chung;Jin Sun Kim
    • Women's Health Nursing
    • /
    • v.29 no.1
    • /
    • pp.20-31
    • /
    • 2023
  • Purpose: As more newborns have received expanded newborn screening (NBS) for metabolic disorders, the overall number of false-positive results has increased. The purpose of this study was to explore the psychological impacts experienced by mothers related to the NBS process. Methods: An online parenting community in Korea was selected, and questions regarding NBS were collected using web crawling for the period from October 2018 to August 2021. In total, 634 posts were analyzed. The collected unstructured text data were preprocessed, and keyword analysis, topic modeling, and visualization were performed. Results: Of 1,057 words extracted from posts, the top keyword based on 'term frequency-inverse document frequency' values was "hypothyroidism," followed by "discharge," "close examination," "thyroid-stimulating hormone levels," and "jaundice." The top keyword based on the simple frequency of appearance was "XXX hospital," followed by "close examination," "discharge," "breastfeeding," "hypothyroidism," and "professor." As a result of LDA topic modeling, posts related to inborn errors of metabolism (IEMs) were classified into four main themes: "confirmatory tests of IEMs," "mother and newborn with thyroid function problems," "retests of IEMs," and "feeding related to IEMs." Mothers experienced substantial frustration, stress, and anxiety when they received positive NBS results. Conclusion: The online parenting community played an important role in acquiring and sharing information, as well as psychological support related to NBS in newborn mothers. Nurses can use this study's findings to develop timely and evidence-based information for parents whose children receive positive NBS results to reduce the negative psychological impact.

Differential Diagnosis of Breast Mass and Staging of Breast Cancer Using F-18-FDG PET (F-18-FDG PET을 이용한 유방종괴의 감별진단과 유방암의 병기설정)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Noh, Dong-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.502-511
    • /
    • 1999
  • Purpose: F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) has been proven to be useful in the differential diagnosis of breast mass and staging of breast cancer. This study assessed the diagnostic accuracy of F-18-FDG PET in the differentiation of breast mass and staging of breast cancer. Materials and Methods: Total 42 patients who had breast mass underwent F-18-FDG PET (all female, 40: 10 year old). We compared F-18 FDG PET results with pathologic findings in 24 patients Results: In the differentiation of breast mass, sensitivity and specificity were 95% (19/20) and 77% (7/9) respectively. Three false positive cases were due to inflammation and one false negative patient had small tumor less than 1 cm. In the assessment of axillary lymph node status, sensitivity and specificity were 73% (8/11) and 100% (7/7) respectively. We found distant metastasis that were not suspected before F-18-FDG PET in 2 patients. Conclusion: F-18-FDG PET shows good diagnostic performance in differentiation of breast mass and staging of breast cancer.

  • PDF

The Study of a Diagnostic Algorithm for the Quantitative Evaluation of Stress Urinary Incontinence (복압성 요실금의 정량적 평가를 위한 진단 알고리즘에 관한 연구)

  • Min, Hae Ki;Kim, Ju Young;Noh, Si Cheol;Choi, Heung Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.277-287
    • /
    • 2018
  • Pelvic floor muscle is the main sub-system that maintains urinary continence. The weakness of pelvic floor muscles causes the stress urinary incontinence, and therefore the degree of functioning of pelvic floor muscles could be used as an index to assess the degree of stress urinary incontinence. In this study, the quantitative diagnosis algorithm was proposed to estimate the degree of stress urinary incontinence (SUI) by measuring the contraction pressure of pelvic floor muscle. For these reason, the contraction pressure measurement system from pelvic floor muscle was developed, and the measuring protocol was suggested to analysis the obtained data. As the results of clinical test, the proposed diagnosis algorithm shows the 80% of accuracy, and 20% of false positive diagnosis. On the other hand, false negative results were not confirmed. Consequentially, we thought that the proposed urinary incontinence diagnosis algorithm can quantitatively diagnose the progression of the stress urinary incontinence and it can be used for the development of the incontinence diagnosis system.

Quality Control Usage in High-Density Microarrays Reveals Differential Gene Expression Profiles in Ovarian Cancer

  • Villegas-Ruiz, Vanessa;Moreno, Jose;Jacome-Lopez, Karina;Zentella-Dehesa, Alejandro;Juarez-Mendez, Sergio
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2519-2525
    • /
    • 2016
  • There are several existing reports of microarray chip use for assessment of altered gene expression in different diseases. In fact, there have been over 1.5 million assays of this kind performed over the last twenty years, which have influenced clinical and translational research studies. The most commonly used DNA microarray platforms are Affymetrix GeneChip and Quality Control Software along with their GeneChip Probe Arrays. These chips are created using several quality controls to confirm the success of each assay, but their actual impact on gene expression profiles had not been previously analyzed until the appearance of several bioinformatics tools for this purpose. We here performed a data mining analysis, in this case specifically focused on ovarian cancer, as well as healthy ovarian tissue and ovarian cell lines, in order to confirm quality control results and associated variation in gene expression profiles. The microarray data used in our research were downloaded from ArrayExpress and Gene Expression Omnibus (GEO) and analyzed with Expression Console Software using RMA, MAS5 and Plier algorithms. The gene expression profiles were obtained using Partek Genomics Suite v6.6 and data were visualized using principal component analysis, heat map, and Venn diagrams. Microarray quality control analysis showed that roughly 40% of the microarray files were false negative, demonstrating over- and under-estimation of expressed genes. Additionally, we confirmed the results performing second analysis using independent samples. About 70% of the significant expressed genes were correlated in both analyses. These results demonstrate the importance of appropriate microarray processing to obtain a reliable gene expression profile.

Discordant findings of dimercaptosuccinic acid scintigraphy in children with multi-detector row computed tomography-proven acute pyelonephritis

  • Lee, Jeong-Min;Kwon, Duck-Geun;Park, Se-Jin;Pai, Ki-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.5
    • /
    • pp.212-218
    • /
    • 2011
  • Purpose: The diagnosis of acute pyelonephritis (APN) is often difficult, as its clinical and biological manifestations are non-specific in children. If not treated quickly and adequately, however, APN may cause irreversible renal damage, possibly leading to hypertension and chronic renal failure. We were suspecting the diagnostic value of $^{99m}Tc$-dimercaptosuccinic acid (DMSA) scan by experiences and so compared the results of DMSA scan to those of multi-detector row computed tomography (MDCT). Methods: We retrospectively selected and analyzed 81 patients who were diagnosed as APN by MDCT during evaluation of their acute abdomen in emergency room and then received DMSA scan also for the diagnostic work-up of APN after admission. We evaluated the results of imaging studies and compared the diagnostic value of each method by age groups, <2 years (n=45) and ${\geq}$2 years (n=36). Results: Among total 81 patients with MDCT-proven APN, DMSA scan was diagnostic only in 55 children (68%), while the remaining 26 children (32%) showed false negative normal findings. These 26 patients were predominantly male and most of them, 19 (73.1%) were <2 years of age. Conclusion: DMSA scan holds obvious limitation compared to MDCT in depicting acute inflammatory lesions of kidney in children with APN, especially in early childhood less than 2 years of age. MDCT showed hidden lesions of APN, those were undetectable through DMSA scan in children.

Performance Improvement of Automatic Basal Cell Carcinoma Detection Using Half Hanning Window (Half Hanning 윈도우 전처리를 통한 기저 세포암 자동 검출 성능 개선)

  • Park, Aa-Ron;Baek, Seong-Joong;Min, So-Hee;You, Hong-Yoen;Kim, Jin-Young;Hong, Sung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.105-112
    • /
    • 2006
  • In this study, we propose a simple preprocessing method for classification of basal cell carcinoma (BCC), which is one of the most common skin cancer. The preprocessing step consists of data clipping with a half Hanning window and dimension reduction with principal components analysis (PCA). The application of the half Hanning window deemphasizes the peak near $1650cm^{-1}$ and improves classification performance by lowering the false negative ratio. Classification results with various classifiers are presented to show the effectiveness of the proposed method. The classifiers include maximum a posteriori probability (MAP), k-nearest neighbor (KNN), probabilistic neural network (PNN), multilayer perceptron(MLP), support vector machine (SVM) and minimum squared error (MSE) classification. Classification results with KNN involving 216 spectra preprocessed with the proposed method gave 97.3% sensitivity, which is very promising results for automatic BCC detection.

  • PDF