• Title/Summary/Keyword: False-Positive Culture

Search Result 34, Processing Time 0.035 seconds

False-Positive Mycobacterium tuberculosis Detection: Ways to Prevent Cross-Contamination

  • Asgharzadeh, Mohammad;Ozma, Mahdi Asghari;Rashedi, Jalil;Poor, Behroz Mahdavi;Agharzadeh, Vahid;Vegari, Ali;Shokouhi, Behrooz;Ganbarov, Khudaverdi;Ghalehlou, Nima Najafi;Leylabadlo, Hamed Ebrahmzadeh;Kafil, Hossein Samadi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.3
    • /
    • pp.211-217
    • /
    • 2020
  • The gold standard method for diagnosis of tuberculosis is the isolation of Mycobacterium tuberculosis through culture, but there is a probability of cross-contamination in simultaneous cultures of samples causing false-positives. This can result in delayed treatment of the underlying disease and drug side effects. In this paper, we reviewed studies on false-positive cultures of M. tuberculosis. Rate of occurrence, effective factors, and extent of false-positives were analyzed. Ways to identify and reduce the false-positives and management of them are critical for all laboratories. In most cases, false-positive is occurring in cases with only one positive culture but negative direct smear. The three most crucial factors in this regard are inappropriate technician function, contamination of reagents, and aerosol production. Thus, to reduce false-positives, good laboratory practice, as well as use of whole-genome sequencing or genotyping of all positive culture samples with a robust, extra pure method and rapid response, are essential for minimizing the rate of false-positives. Indeed, molecular approaches and epidemiological surveillance can provide a valuable tool besides culture to identify possible false positives.

Evaluation of Negative Results of BacT/Alert 3D Automated Blood Culture System

  • Kocoglu M. Esra;Bayram Aysen;Balcl Iclal
    • Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.257-259
    • /
    • 2005
  • Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (BPA) and anaerobic (BPN) media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in $5\%$ sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four $(2.6\%)$ of the 904 subcultures grew on the subculture media. The majority $(83.3\%)$ of these were determined to be gram-positive microorganisms. Fourteen $(58.3\%)$ were coagulase-negative staphylococci, two $(8.3\%)$ were Bacillus spp., one $(4.2\%)$ was Staphylococcus aureus, and one $(4.2\%)$ was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two $(8.3\%)$ vials. Gram-negative microorganisms comprised $12.5\%$ of the subcultures, of which two $(8.3\%)$ were found to be Pseudomonas aeruginosa, and one $(4.2\%)$ was Pseudomonas fluorescens. The other isolate $(4.2\%)$ was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

Validity of bag urine culture for predicting urinary tract infections in febrile infants: a paired comparison of urine collection methods

  • Kim, Geun-A;Koo, Ja-Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.5
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: Catheter urine (CATH-U) and suprapubic aspiration (SPA) are reliable urine collection methods for confirming urinary tract infections (UTI) in infants. However, noninvasive and easily accessible collecting bag urine (CBU) is widely used, despite its high contamination rate. This study investigated the validity of CBU cultures for diagnosing UTIs, using CATH-U culture results as the gold standard. Methods: We retrospectively analyzed 210 infants, 2- to 24-month-old, who presented to a tertiary care hospital's pediatrics department between September 2008 and August 2013. We reviewed the results of CBU and CATH-U cultures from the same infants. Results: CBU results, relative to CATH-U culture results (${\geq}10^4$ colony-forming units [CFU]/mL) were widely variable, ranging from no growth to ${\geq}10^5CFU/mL$. A CBU cutoff value of ${\geq}10^5CFU/mL$ resulted in false-positive and false-negative rates of 18% and 24%, respectively. The probability of a UTI increased when the CBU bacterial count was ${\geq}10^5/mL$ for all infants, both uncircumcised male infants and female infants (likelihood ratios [LRs], 4.16, 4.11, and 4.11, respectively). UTIs could not be excluded for female infants with a CBU bacterial density of $10^4-10^5$ (LR, 1.40). The LRs for predicting UTIs based on a positive dipstick test and a positive urinalysis were 4.19 and 3.11, respectively. Conclusion: The validity of obtaining urine sample from a sterile bag remains questionable. Inconclusive culture results from CBU should be confirmed with a more reliable method.

Study on the Enumeration of Legionella in Environmental Water Samples Using Real-time PCR (Real-time PCR을 이용한 환경 중 물 시료의 레지오넬라 분석법 연구)

  • Lee, Jung-Hee;Park, Myoung-Ki;Kim, Yun-Sung;Yun, Hee-Jeong;Lee, Chang-Hee;Jeong, Ah-Yong;Yoon, Mi-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • Objectives: The standard method for the enumeration of environmental Legionella is culturing, which has several disadvantages, including long incubation and poor sensitivity. The purpose of this study is to demonstrate the usefulness of real-time PCR and to improve the standard method. Methods: In 200 environmental water samples, a real-time PCR and culture were conducted to detect and quantify Legionella. Using with the results of the survey, we compared the real-time PCR with the culture. Results: Each real-time PCR assay had 100% specificity and excellent sensitivity (5 GU/reaction). In the culture, 36 samples were positive and 164 samples were negative. Based on the results of the culture, real-time PCR showed a high negative predictive value of 99%, 35 samples were true positive, 105 samples were true negative, 59 samples were false positive and one sample was a false negative. Quantitative analysis of the two methods indicated a weak linear correlation ($r^2=0.29$, $r^2=0.61$, respectively). Conclusions: Although it is difficult to directly apply quantitative analysis results of real-time PCR in the enumeration of environmental Legionella, it can be used as a complementary means of culturing to rapidly screen negative samples and to improve the accuracy of diagnosis.

Comparison of Culture, Conventional and Real-time PCR Methods for Listeria monocytogenes in Foods

  • Kim, Dong-Hyeon;Chon, Jung-Whan;Kim, Hyunsook;Kim, Hong-Seok;Choi, Dasom;Kim, Young-Ji;Yim, Jin-Hyeok;Moon, Jin-San;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.34 no.5
    • /
    • pp.665-673
    • /
    • 2014
  • We compared standard culture methods as well as conventional PCR and real-time PCR for the detection of Listeria monocytogenes (L. monocytogenes) in milk, cheese, fresh-cut vegetables, and raw beef that have different levels of background microflora. No statistical differences were observed in sensitivity between the two selective media in all foods. In total, real-time PCR assay exhibited statistically excellent detection sensitivity (p<0.05) and was less time consuming and laborious as compared with standard culture methods. Conventional culture methods showed poor performance in detecting L. monocytogenes in food with high levels of background microflora, generating numerous false negative results. While the detection of L. monocytogenes in fresh cut vegetable by culture methods was hindered only by L. innocua, various background microflora, such as L. innocua, L. welshimeri, L. grayi, and Enterococcus faecalis appeared on the two selective media as presumptive positive colonies in raw beef indicating the necessity of improvement of current selective media. It appears that real-time PCR is an effective and sensitive presumptive screening tool for L. monocytogenes in various types of foods, especially foods samples with high levels of background microflora, thus complementing standard culture methodologies.

A Comparative Analysis on The Efficiency of Various Clinical Methods for Diagnosis of Tuberculosis (결핵 진단을 위한 검사 방법간의 효율성에 관한 비교 분석)

  • 최석철;정천환;성희경;김태운;이원재
    • Biomedical Science Letters
    • /
    • v.5 no.2
    • /
    • pp.191-200
    • /
    • 1999
  • In recent years continuously increasing number of tuberculosis (TB) cases due to the emergence of strains with multidrug resistance and AIDS is a significant global health problem. Therefore, more rapid and reliable diagnosis of TB may be one of the most urgent needs in efforts to eradicate the disease. The present study was designed to compare and assess the diagnostic values and efficiencies between the conventional methods (X-ray, AFB stain and culture) and PCR for pulmonary TB on 171 cases. Chest X-ray finding and clinical features revealed that 39 (22.8%) of 171 sputum specimens were pulmonary TB cases. The statistical data were taken on the basis of the definitive diagnosis: In X-ray, overall sensitivity, specificity, efficiency and false positive and false negative incidence was respectively 69.2%, 87.1%, 83.0%, 12.9%, and 30.8%; 79.5%, 95.5%, 91.8%,4.6% and 20.5% in AFB-stain; 56.4%, 99.2%,89.5%, 0.8% and 43.6% in culture; 82.1%, 96.2%, 93.0%, 3.8% and 17.9% in PCR. PCR got a highest sensitivity and efficiency as well as a lowest false negative incidence. Culture had a highest specificity with a lowest false positive incidence. These results imply that PCR assay is fast, sensitive and efficient method for diagnosis of pulmonary TB. However, combined use of the conventional methods with thorough quality control may offer more opportunities for detecting Mycobacterium tuberculosis and diagnosting TB although they have some limits.

  • PDF

Design and Implementation of Fire Detection System Using New Model Mixing

  • Gao, Gao;Lee, SangHyun
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.260-267
    • /
    • 2021
  • In this paper, we intend to use a new mixed model of YoloV5 and DeepSort. For fire detection, we want to increase the accuracy by automatically extracting the characteristics of the flame in the image from the training data and using it. In addition, the high false alarm rate, which is a problem of fire detection, is to be solved by using this new mixed model. To confirm the results of this paper, we tested indoors and outdoors, respectively. Looking at the indoor test results, the accuracy of YoloV5 was 75% at 253Frame and 77% at 527Frame, and the YoloV5+DeepSort model showed the same accuracy at 75% at 253 frames and 77% at 527 frames. However, it was confirmed that the smoke and fire detection errors that appeared in YoloV5 disappeared. In addition, as a result of outdoor testing, the YoloV5 model had an accuracy of 75% in detecting fire, but an error in detecting a human face as smoke appeared. However, as a result of applying the YoloV5+DeepSort model, it appeared the same as YoloV5 with an accuracy of 75%, but it was confirmed that the false positive phenomenon disappeared.

The Diagnostic Value of Bronchoalveolar lavage fluid microscopic study and PCR in Pulmonary tuberculosis (폐결핵에 있어서 기관지폐포세척액 결핵균검사 및 PCR의 진단적 가치)

  • Park, Moon-Hwan;Choi, Choon-Han;Kim, Nam-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.128-137
    • /
    • 1996
  • Background : We can diagnose pulmonary tuberculosis with sputum AFB smear and culture, but sputum AFB smear has low sensitivity and culture needs long period, and they are not available in the patients who can not expectorate effectively. Recently developed, PCR is a fast diagnostic tool in tuberculosis, but false positive and false negative are important problems. So, we studied the diagnostic value of bronchoalveolar lavage fluid AFB smear, culture, PCR through the bronchoscopy. Methods : The 67 pulmonary tuberculosis patients and 43 non-pulmonary tuberculosis patients were analyzed with their sputum specimen AFB smear and culture. Also, bronchoscopy and bronchoalveolar lavage were done, and bronchoalveolar lavage fluid AFB smear, culture and PCR were done. Results: 1) In the cases of pulmonary tuberculosis, the sensitivity of sputum AFB smear and culture were 32.8% and 57.4%, respectively. And the sensitivity of bronchoalveolar lavage fluid AFB smear and culture were 47.8% and 80.6%. respectively. 2) In the cases of pulmonary tuberculosis, the sensitivity and the positive predictive value(for predicting a positive culture) of PCR were 80.6% and 81.5%, respectively. 3) In the cases of sputum AFB smear-negative and culture-negative pulmonary tuberculosis, the sensitivity of bronchoalveolar lavage fluid AFB smear, culture, PCR, and the positive predictive value(for predicting a positive culture) of PCR were 23.1%, 100%, 88.5%, and 82.4%, respectively. 4) The specificity of bronchoalveolar lavage fluid PCR was 77.0%. 5) The median number of days between obtaining a specimen and starting therapy was 5 days for sputum AFB smear, 9 days for bronchoalveolar lavage fluid AFB smear, 26 days for bronchoalveolar lavage fluid PCR, 32 days for sputum culture, 56 days for bronchoalveolar lavage fluid culture. Conclusion : The sensitivity of bronchoalveolar lavage fluid AFB smear and culture are higher than sputum AFB smear and culture. So, the bronchoscopy must be considered for evaluating suspected cases of pulmonary tuberculosis in patients from whom smears of expectorated sputum do not reveal mycobacteria or from whom no sputum can be obtained. Especially, combined with PCR, it is expected that pulmonary tuberculosis can be diagnosed more rapidly and more accurately, so bronchoalveolar lavage fluid APB smear and PCR can be helpful in the early treatment of pulmonary tuberculosis.

  • PDF

Study on Characteristics and User Reactions of Videos Related to COVID-19 Vaccine (코로나19 백신 관련 영상의 특성 및 이용자 반응에 대한 연구)

  • Lee, Mina;Hong, Juhyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.163-171
    • /
    • 2021
  • This study aimed to investigate the main characteristics of the COVID-19 vaccine-related videos spread on YouTube and differences in user responses in the infodemic situation caused by COVID-19. As a result of content analysis of 579 videos related to the COVID-19 vaccine, it was found that all of the false information was written by individual channels. Institutions, organizations, media companies, and government channels reported spread of false information as well as fact-oriented reporting. The progressive channel had a high percentage of positive sentiment in favor of vaccination, and the conservative channel had a high percentage of negative emotion against vaccination. After the vaccination started, the number of videos on government channels increased, and it was found that the number of videos with positive emotions increased. Results of regression analysis of video characteristics that affect the number of likes indicated that personal expert videos and videos from progressive channels received more likes. Combining the research results, we propose a plan to promote government policies regarding the COVID-19 vaccine using social media.

Enhancement program of social information processing based on metacognitive training for Schizophrenia patients

  • Park, Sungwon
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.96-102
    • /
    • 2019
  • The purpose of this study was to examine the effects of applying a program to enhance social information processing ability in schizophrenic patients. We confirmed the positive effects of the program on the theories of mind and attribution style, which are the social information elements of patients, and confirmed the effect of decreasing paranoid ideation. We used the theory of mind(hinting task, the false belief task), the attributional style questionnaire(external bias, personal bias), and the paranoia scale to test the effectiveness of the program. Specifically, in theory of mind, hinting task performance was improved(t=4.14, p=.000),. The scores of personal bias(t=-7.9, p=.000) and paranoid ideation(t=-2.98, p=.004) decreased. Further research is needed to verify the effectiveness of meta - cognitive training to enhance social information processing.