• 제목/요약/키워드: False positive rate

검색결과 294건 처리시간 0.028초

자궁경부 편평상피병변에서 자궁경부질도말 세포검사의 진단정확도 : 481예의 세포-조직 상관관계 (Diagnostic Accuracy of Cervicovaginal Cytology in the Detection of Squamous Epithelial Lesions of the Uterine Cervix; Cytologic/Histologic Correlation of 481 Cases)

  • 진소영;박상모;김미선;진윤미;김동원;이동화
    • 대한세포병리학회지
    • /
    • 제19권2호
    • /
    • pp.111-118
    • /
    • 2008
  • Background : Cervicovaginal cytology is a screening test of uterine cervical cancer. The sensitivity of cervicovaginal cytology is less than 50%, but studies of cytologic/histologic correlation are limited. We analyzed the diagnostic accuracy of cervicovaginal cytology in the detection of the squamous epithelial lesions of the uterine cervix and investigate the cause of diagnostic discordance. Materials and Methods : We collected a total of 481 sets of cervicovaginal cytology and biopsies over 5 years. The cytologic diagnoses were categorized based on The Bethesda System and the histologic diagnoses were classified as negative, flat condyloma, cervical intraepithelial neoplasia (CIN) I, CIN II, CIN III, or squamous cell carcinoma. Cytohistologic discrepancies were reviewed. Results: The concordance rate between the cytological and the histological diagnosis was 79.0%. The sensitivity and specificity of cervicovaginal cytology were 80.6% and 92.6%, respectively. Its positive predictive value and negative predictive value were 93.7% and 77.7%, respectively. The false negative rate was 19.4%. Among 54 false negative cytology cases, they were confirmed by histology as 50 flat condylomas, 2 CIN I, 1 CIN III, and 1 squamous cell carcinoma. The causes of false negative cytology were sampling errors in 75.6% and interpretation errors in 24.4%. The false positive rate was 7.4%. Among 15 false positive cytology cases, they were confirmed by histology as 12 atypical squamous cells of undetermined significance (ASCUS) and 3 low grade squamous intraepithelial lesions (LSIL). The cause of error was interpretation error in all cases. The overall diagnostic accuracy of cervicovaginal cytology was 85.7%. Conclusions : Cervicovaginal cytology shows high overall diagnostic accuracy and is a useful primary screen of uterine cervical cancer.

나안 두부충동검사에서 위음성의 원인분석 (Causes of False Negative Bedside Head Impulse Test)

  • 김대영;최윤기;경태석;황준하;김현지;이승철;김규성
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • 제60권3호
    • /
    • pp.107-111
    • /
    • 2017
  • Background and Objectives The bedside head impulse test (bHIT) in bare eyes often overlooks possible vestibular losses by missing the corrective saccade. This is why it is necessary to compare bHIT against video head impulse test (vHIT), which is more accurate in identifying vestibular losses than the bedside test. Subjects and Method A total of 51 vHIT positive ears underwent the study, and out of those, 47 were diagnosed with dizziness. bHIT and vHIT were performed for patients, and the occurrence rate of overt saccade (OS) was calculated. Results Among the 51 vHIT positive ears, 33 (64.7%) were bHIT positive ears and 18 ears (35.3%) were bHIT negative. Patterns of positive vHIT were classified as A: no corrective saccade, B: covert saccade (CS) only, C: OS only, and D: CS with OS (CS+OS), which were 45 out of 51 ears (88%). The occurrence rate of OS was higher in the bHIT positive group than in the bHIT negative group (p=0.05), and higher in the CS negative group (CS-) than in the CS positive group (CS+) (p<0.001). Conclusion Possible causes of false negative results of bHIT are seen as following: the absence of corrective (covert and overt) saccade, the occurrence of CS only, and missing the OS during the bHIT (probably due to low occurrence rate of OS). The occurrence of CS should be considered as an important factor in false negative bHIT when lowering the occurrence rate of OS.

A novel watermarking scheme for authenticating individual data integrity of WSNs

  • Guangyong Gao;Min Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권3호
    • /
    • pp.938-957
    • /
    • 2023
  • The limited computing power of sensor nodes in wireless sensor networks (WSNs) and data tampering during wireless transmission are two important issues. In this paper, we propose a scheme for independent individual authentication of WSNs data based on digital watermarking technology. Digital watermarking suits well for WSNs, owing to its lower computational cost. The proposed scheme uses independent individual to generate a digital watermark and embeds the watermark in current data item. Moreover, a sink node extracts the watermark in single data and compares it with the generated watermark, thereby achieving integrity verification of data. Inherently, individual validation differs from the grouping-level validation, and avoids the lack of grouping robustness. The improved performance of individual integrity verification based on proposed scheme is validated through experimental analysis. Lastly, compared to other state-of-the-art schemes, our proposed scheme significantly reduces the false negative rate by an average of 5%, the false positive rate by an average of 80% of data verification, and increases the correct verification rate by 50% on average.

명령 실행 모니터링과 딥 러닝을 이용한 파워셸 기반 악성코드 탐지 방법 (PowerShell-based Malware Detection Method Using Command Execution Monitoring and Deep Learning)

  • 이승현;문종섭
    • 정보보호학회논문지
    • /
    • 제28권5호
    • /
    • pp.1197-1207
    • /
    • 2018
  • 파워셸은 닷넷 프레임워크를 기반에 둔, 커맨드 라인 셸이자 스크립트 언어로, 그 자체가 가진 다양한 기능 외에도 윈도우 운영체제 기본 탑재, 코드 은닉 및 지속의 수월함, 다양한 모의 침투 프레임워크 등 공격 도구로서 여러 이점을 가지고 있다. 이에 따라 파워셸을 이용하는 악성코드가 급증하고 있으나 기존의 악성코드 탐지 기법으로 대응하기에는 한계가 존재한다. 이에 본 논문에서는 파워셸에서 실행되는 명령들을 관찰할 수 있는 개선된 모니터링 기법과, Convolutional Neural Network(CNN)을 이용해 명령에서 특징을 추출하고 실행 순서에 따라 Recurrent Neural Network(RNN)에 전달하여 악성 여부를 판단하는 딥 러닝 기반의 분류 모델을 제안한다. 악성코드 공유 사이트에서 수집한 파워셸 기반 악성코드 1,916개와 난독화 탐지 연구에서 공개한 정상 스크립트 38,148개를 이용하여 제안한 모델을 5-fold 교차 검증으로 테스트한 결과, 약 97%의 True Positive Rate(TPR)와 1%의 False Positive Rate(FPR)로 모델이 악성코드를 효과적으로 탐지함을 보인다.

Rapid Identification of Candida albicans Using Colorimetric Method

  • Kim, Shin Young;Park, Hun-Hee
    • 대한임상검사과학회지
    • /
    • 제45권4호
    • /
    • pp.149-153
    • /
    • 2013
  • Candidiasis is a fungal infection of the most common causes; generally, opportunistic infections occur often in patients with weakened immune systems. Because of high rates in fungal infection patients and increasing frequency of being isolated from clinical materials, quickly identifying of Candida albicans is critical. By identifying 404 yeast cell strains of referred samples via API 20C kits, NGL and PRO tests and Germ tube (GT) test were conducted and compared. In the 3.0 McFarland yeast cells, 0.1% ${\rho}-nitrophenyl-N-acetyl-{\beta}-D-galactosaminide$ (NGL) and 0.04% ${\small{L}}$-proline ${\beta}$-naphtylamide (PRO) were each put in test tubes and incubated at $35^{\circ}C$ for 15, 30, 60 and 90 minutes. Afterwards, 1 drop of 2% NaOH was applied, and if the color turned yellow; it was positive for NGL test. Afterwards, 1% ${\rho}$-dimethylaminocinnamaldehyde was applied, and if the upper layer turned pink or red, it was positive for PRO test. NGL and PRO tests were conducted for all C. albicans and identified accurately within 30 minutes. In NGL, PRO test, false-positive, negative were not seen, whereas, GT test showed false-positive in 1 strain and false-negative in 3 strains. Therefore, sensitivity and specificity of NGL, PRO tests were 100% and 99.5%, respectively, and positive and negative predictive rate were 99.5% and 100%, respectively. However, GT test sensitivity and specificity were 98.5% and 99.5%, respectively, and positive and negative predictive rates were 99.5% and 98.5%, respectively. In conclusion, NGL, PRO tests are better than GT tests for sensitivity and specificity, therefore, these reliable tests will be useful in clinical laboratories.

  • PDF

기관지 세척액 검사를 이용한 MAGE 유전자 검사의 임상적 의의 (The Clinical Implication of MAGE Gene Detection in Bronchial Washing Fluid in Routine Practice)

  • 이승준;윤명재;이성태;오혜진;송숙희;손인;김연정;한경훈;김선희;김수현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제69권6호
    • /
    • pp.442-449
    • /
    • 2010
  • Background: Melanoma antigen genes (MAGE) are expressed in many human malignant cells and are silent in normal tissues other than in testis and in placenta. But MAGE expression in benign lung diseases, such as pulmonary tuberculosis or cases with severe inflammation, needs further evaluation to overcome false-positive findings. We evaluated detection rates of the melanoma antigen genes (MAGE) RT-nested PCR in bronchoscopic washing samples from patients with benign lung disease, as well as in patients with malignancies. Methods: Bronchial washing fluid from 122 patients was used for cytological examination and MAGE gene detection using RT-nested-PCR of common A1-6 mRNA. We compared the results from the RT-nested PCR and the pathologic or bacteriologic diagnosis. We also analyzed the expression rate and false positive rate of MAGE gene. Results: Among 122 subjects, lung cancer was diagnosed in 23 patients and benign lung disease was diagnosed in 99 patients. In patients with lung cancer, the positive rate of MAGE expression was 47.8% (11/23) and in benign lung disease group, the expression rate was 14.1% (14/99). Among benign lung disease group, the expression rate of MAGE gene (25.0%) in patients with pulmonary tuberculosis (11/44) was especially high. Conclusion: MAGE A1-6 RT-nested PCR of bronchial washing fluid can be used as a complementary method in lung cancer, but that test results in a high false positive rate in tuberculosis patients.

B형 간염 바이러스 표면 항체 검출을 위한 Passive Hemagglutination (PHA)방법의 정확도에 관한 연구 (A Study on the Validity of Passive Hemagglutination (PHA) Test for HBsAb)

  • 박병주
    • Journal of Preventive Medicine and Public Health
    • /
    • 제20권1호
    • /
    • pp.114-119
    • /
    • 1987
  • The author investigated the effect of some variables such as age, sex and the experience of past vaccination on the validity of PHA. The changing pattern of the validity with the change of PHA diagnostic criteria, and the relationship between PHA test result and RIA Ratio Unit were also studied. The results obtained were as follow; 1) No statistically significant difference was found in sensitivity, specificity and negative predictability by sex, but positive predictability was significantly higher in male than that in female. 2) Positive predictability was shown to become higher with the increase of age and nagative predictability was found to be significally different among age groups, but no statistically significant difference was found in sensitivity and specificity by age group. 3) Significantly low specificity and high positive predictability were found in past vaccined group, but no statistically significant difference was found in sensitivity and negative predictability between past vaccined group and non-vaccined group. 4) False negative cases by PHA were found to be the weak positive reactors by RIA and false positive rate of PHA was as high as 46.3 per cent. 5) Sensitivity and specificity of PHA at the diagnostic criteria of HBsAb titer 1:2 were 98.4% and 53.8% respectively, but after increasing the HBsAb titer to 1:64 as the diagnostic criteria the results were 60.0% and 95.6% respectively.

  • PDF

Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology

  • Tanabodee, Jitraporn;Thepsuwan, Kitisak;Karalak, Anant;Laoaree, Orawan;Krachang, Anong;Manmatt, Kittipong;Anontwatanawong, Nualpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7381-7384
    • /
    • 2015
  • This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

코로나19 진단을 위한 잡음 그룹검사의 성능분석 (Performance Analysis of Noisy Group Testing for Diagnosis of COVID-19 Infection)

  • 성진택
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.117-123
    • /
    • 2022
  • 현재 코로나19 확진자는 전 세계적으로 빠르게 증가하고 있다. 감염 확산을 억제할 수 있는 방법으로 신속한 코로나19 검사를 통한 확진자를 찾아내는 것이다. 본 논문에서는 코로나19 진단을 위한 잡음 그룹검사(Noisy Group Testing) 문제를 살펴본다. 기존에 제안한 그룹검사 문제는 측정잡음을 무시하였지만, 최근 들어 코로나19 검사시에 위 양성(false positive)과 위음성(false negative) 사례가 발생하고 있다. 이에 대해 본 논문에서는 잡음 그룹검사 문제를 정의하고 측정잡음이 성능에 얼마나 영향을 미치는지 분석한다. 본 연구를 통해 우리는 코로나19 검사 양성률이 낮은 그룹검사를 수행할수록 측정잡음(measurement noise)에 덜 민감하도록 그룹검사 시스템이 설계되어야 함을 제시한다. 또한 최근 발표한 다른 복원 알고리즘들과 비교하여 본 연구에서 제안하는 신호 복원 알고리즘이 잡음 그룹검사에서 좋은 성능을 보여준다.

유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구 (Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions)

  • 강미선;정수진;윤혜경
    • 대한세포병리학회지
    • /
    • 제8권2호
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF