A Study on Heat and Mass Transfer in a Vertical Tube Absorber Using LiBr Family Solutions (LiBr계 용액을 사용한 수직관 흡수기의 열 및 물질 전달에 관한 연구)

  • Cho, H.C.;Kim, C.B.;Jeong, S.Y.;Kang, S.W.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.196-206
    • /
    • 1995
  • Experimental investigations on heat and mass transfer characteristics in a vertical tube absorber have been carried out. Three different copper tubes with a length of 1.5m have been tested using LiBr solution and LiBr-$CaCl_2$ solution. The effects of solution flow rate, cooling water temperature, solution inlet temperature and evaporation temperature have been investigated in detail. It is found that heat transfer coefficient increases gradually with the increase of solution flow rate, but decreases rapidly for the flow rates less than 0.02kg/ms. The grooved tube generally shows better heat transfer performances than the smooth tube. LiBr solution shows almost no absorption capability for the cooling water temperatures over $40^{\circ}C$. LiBr-$CaCl_2$ gives less decreasing rate in absorption capability at these temperatures and the heat transfer coefficient becomes less dependent on the types of tubes in use. Considering heat and mass transfer rates, LiBr-$CaCl_2$ solution is found to be more suitable than LiBr solution for air cooled absorber, which operates at higher temperature than water cooled absorber.

  • PDF

Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate (용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험)

  • Moon, C.G.;Bang, G.S.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

Characteristic of Heat and Mass Transfer on Helical Absorber Using New Working Fluid (신작동매체를 이용한 헬리컬 흡수기의 열물질전달 특성)

  • Kwon, Oh-Kyung;Lim, Jong-Keuk;Yoon, Jung-In
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.228-233
    • /
    • 2000
  • An experimental study has been performed regarding heat and mass transfer in a falling film absorber of domestic small-sized absorption chiller/heater. Components were concentrically arranged in cylindrical form : from the center, with a series of low temperature generator, absorber and evaporator. The arrangement of such helical-typed heat exchangers allows to make the system more compact as compared to conventional one. Experimental measurements were conducted with a helical absorber using $LiBr+LiI+LiNO_3+LiCl$ and LiBr solutions. As a result, the heat and mass flux performance of $LiBr+LiI+LiNO_3+LiCl$ solution shows the tendency of $2{\sim}5%$ increase. Therefore, $LiBr+LiI+LiNO_3+LiCl$ solution can be taken consideration into applying to small-sized absorption chiller/heater because of using without crystal through high concentration as 4wt% comparing with LiBr solution.

  • PDF

Experimental Study on Heat Transfer Performance of Absorber with Variable Plate Types

  • M.A. Sarker;Moon, C.G.;Lee, H.S.;Kim, E.P.;Yoon, J.I.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.201-212
    • /
    • 2004
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of developing high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is important to improve the performance of absorber with the larger heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which could increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, that is, horizontal tube bundle type. The size of plate absorbers were made for 0.4m$\times$0.6m and the design objective of a refrigeration capacity was 1RT. In this experiment, three kinds of plate absorbers namely flat plate, dimple plate and groove plate were used. The obtained results were less than the design objective values, that is, the refrigeration capacity was about 0.3 ~0.4RT and the overall heat transfer coefficient was 500~600 kcal/$m^2$h$^{\circ}C$ at the standard conditions.

  • PDF

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical inner Tube (1st Report, Characteristics of Absorption) (수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性) (제(第) 1 보(報), 흡수특성(吸收特性)))

  • Ohm, K.C.;Kashiwagi, T.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1993
  • Mass transfer coefficients were measured for water vapor absorption into a LiBr-Water solution of 60wt% flowing down an absorber of vertical tube type. The absorber is copper tube of 25mm inner diameter and 1000mm length. The film Reynolds number were varied in the range of 35~130. The solution is fed from the top of the pipe, and the conditions of solution are supercooled liquid and superheated liquid. As results, the flowrates of LiBr solution which takes peak value of average absorption mass flux exist. Mass transfer coefficients decrease with increasing the flowrate of LiBr solution, and the decrease rate in the case of supercooled liquid is large as compared with that in the case of superheated liquid. But the absorption rate of supercooled liquid is decidedly superior to that of superheated liquid.

  • PDF

Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I) (수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향)

  • Kim, Byeong-Ju;Lee, Chan-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.

Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber (수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.194-202
    • /
    • 2005
  • The present study was analytically and experimentally carried out to predict the absorption characteristics on combined heat and mass transfer process in a vertical falling film of variable absorbers. Heat and mass transfer enhancements were analytically investigated. Effects of geometric parameters by insert device (spring) and corrugate, flow pattern on absorption performances has been also investigated. Especially, the optimal values of absorber geometry (ID=22.8mm, L=1150m) and kinetic variables (solution flow rate, flow pattern) for maximum absorption performance has been predicted by the numerical analysis. The maximum absorption performance in a numerical analysis and experiment was shown at the wavy-flow by insert device (spring).

Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (II) (수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향)

  • Kim, Byeong-Ju;Lee, Chan-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.499-509
    • /
    • 1998
  • In the absorption process of water vapor in a liquid film, the composition of the gas phase, in which a non-absorbable gas is combined with the absorbate influences the transport characteristics remarkably. In the present study, the absorption processes of water vapor into aqueous solution of lithium bromide in the presence of non-absorbable gases were investigated analytically. The continuity, momentum, energy and diffusion equations for the solution film and gas phase were formulated in integral forms and solved numerically. It was found that the mass transfer resistance in gas phase increased with the concentration of non-absorbable gas. However the primary resistance to mass transfer was in the liquid phase. As the concentration of non-absorbable gas in the absorbate increased, the liquid-vapor interfacial temperature and concentration of absorbate in solution decreased, which resulted in the reduction of absorption rate. The reduction of mass transfer rate was found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of an absorber where non-absorbable gases accumulated. At higher non-absorbable gas concentration, the decrease of absorption flux was almost linear to the volumetric concentration of non-absorbable gas.

An Experimental Study on Falling Film Heat and Mass Transfer for Binary Nanofluids ($H_2O$/LiBr+Nanoparticles) (이성분 나노유체($H_2O$/LiBr+나노입자)를 적용한 유하박막 흡수기의 열 및 물질전달 촉진 실험)

  • Kim, Hyun-Dae;Kim, Sung-Su;Nam, Sang-Chul;Jeong, Jin-Hee;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.130-135
    • /
    • 2008
  • The objectives of this study are to investigate the combined heat and mass transfer enhancement using binary nanofluids as the working fluids in a $H_2O$/LiBr absorber. The result of heat and mass transfer experiment with the additives(Arabicgum, 2E1H) showed that the heat and mass transfer performance of binary nanofluid with 2E1H enhanced significantly in comparison with that without additive. In the case of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H, the vapor absorption rate increased up to 77% in comparison with that without additive. The heat transfer rate of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H increased up to 19%. Based on the experimental results, it is recommended that the $Al_2O_3$ binary nanofluid be good with 2E1H to improve the heat and mass transfer performance.

  • PDF