• Title/Summary/Keyword: Failure of fixation

Search Result 163, Processing Time 0.03 seconds

Biomechanical investigation of arm position on deforming muscular forces in proximal humerus fractures

  • Christen E. Chalmers;David J. Wright;Nilay A. Patel;Hunter Hitchens;Michelle McGarry;Thay Q. Lee;John A. Scolaro
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.282-287
    • /
    • 2022
  • Background: Muscular forces drive proximal humeral fracture deformity, yet it is unknown if arm position can help mitigate such forces. Our hypothesis was that glenohumeral abduction and humeral internal rotation decrease the pull of the supraspinatus and subscapularis muscles, minimizing varus fracture deformity. Methods: A medial wedge osteotomy was performed in eight cadaveric shoulders to simulate a two-part fracture. The specimens were tested on a custom shoulder testing system. Humeral head varus was measured following physiologic muscle loading at neutral and 20° humeral internal rotation at both 0° and 20° glenohumeral abduction. Results: There was a significant decrease in varus deformity caused by the subscapularis (p<0.05) at 20° abduction. Significantly increasing humeral internal rotation decreased varus deformity caused by the subscapularis (p<0.05) at both abduction angles and that caused by the supraspinatus (p<0.05) and infraspinatus (p<0.05) at 0° abduction only. Conclusions: Postoperative shoulder abduction and internal rotation can be protective against varus failure following proximal humeral fracture fixation as these positions decrease tension on the supraspinatus and subscapularis muscles. Use of a resting sling that places the shoulder in this position should be considered.

The Results of the First Ray Forefoot Osteotomy Using Low Profile Wedge Plate without a Bone Grafting for Pes Planus Correction (제 1열 전족부 절골술을 통한 평발 교정에 있어 골이식 없이 사용한 소형 쐐기형 금속판의 치료 결과)

  • Choi, Jun Young;Shin, Myung Jin;Suh, Jin Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Purpose: We retrospectively analyzed the radiographic and clinical results after the first ray of forefoot osteotomy using low profile wedge plate without additional cancellous bone grafting for pes planus correction. Materials and Methods: Twenty-four patients were enrolled in this study. Medial cuneiform opening wedge osteotomy was performed in 12 patients (Cotton osteotomy, group C) and first metatarsal base osteotomy was performed in 12 patients (group MT). Results: On average, the wedge size was 5.61 mm (5~6 mm). The mean time to radiographic union was 3.18 and 3.27 months in groups C and MT, respectively. Postoperative talonavicular coverage angle, talo-first metatarsal angle (anteroposterior), talo-first metatarsal angle (lateral), talo-calcaneal angle (lateral), medial cuneiform height, and American orthopaedic foot, as well as ankle society midfoot scale were significantly improved in both groups. Nonunion, delayed union or fixation failure was not presented in our series. Conclusion: We have shown that low profile wedge plate was effective in the case of first ray forefoot osteotomy for pes planus correction without any additional cancellous bone grafting.

Recent updates for biomaterials used in total hip arthroplasty

  • Hu, Chang Yong;Yoon, Taek-Rim
    • Biomaterials Research
    • /
    • v.22 no.4
    • /
    • pp.259-270
    • /
    • 2018
  • Background: Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods: A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'total hip arthroplasty', 'biomaterials', 'stainless steel', 'cobalt-chromium', 'titanium', 'polyethylene', and 'ceramic'. Results: The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion: This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Clinical characteristics of patients with the hardware failure after surgical stabilization of rib fractures in Korea: a case series

  • Na Hyeon Lee;Sun Hyun Kim;Seon Hee Kim;Dong Yeon Ryu;Sang Bong Lee;Chan Ik Park;Hohyun Kim;Gil Hwan Kim;Youngwoong Kim;Hyun Min Cho
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.196-205
    • /
    • 2023
  • Purpose: Surgical stabilization of rib fractures (SSRF) is widely used in patients with flail chests, and several studies have reported the efficacy of SSRF even in multiple rib fractures. However, few reports have discussed the hardware failure (HF) of implanted plates. We aimed to evaluate the clinical characteristics of patients with HF after SSRF and further investigate the related factors. Methods: We retrospectively reviewed the electronic medical records of patients who underwent SSRF for multiple rib fractures at a level I trauma center in Korea between January 2014 and January 2021. We defined HF as the unintentional loosening of screws, dislocation, or breakage of the implanted plates. The baseline characteristics, surgical outcomes, and types of HF were assessed. Results: During the study period, 728 patients underwent SSRF, of whom 80 (10.9%) were diagnosed with HF. The mean age of HF patients was 56.5±13.6 years, and 66 (82.5%) were men. There were 59 cases (73.8%) of screw loosening, 21 (26.3%) of plate breakage, 17 (21.3%) of screw migration, and seven (8.8%) of plate dislocation. Nine patients (11.3%) experienced wound infection, and 35 patients (43.8%) experienced chronic pain. A total of 21 patients (26.3%) underwent reoperation for plate removal. The patients in the reoperation group were significantly younger, had fewer fractures and plates, underwent costal fixation, and had a longer follow-up. There were no significant differences in subjective chest symptoms or lung capacity. Conclusions: HF after SSRF occurred in 10.9% of the cases, and screw loosening was the most common. Further longitudinal studies are needed to identify risk factors for SSRF failure.

Surgical outcomes of sternal rigid plate fixation from 2005 to 2016 using the American College of Surgeons-National Surgical Quality Improvement Program database

  • Tran, Bao Ngoc N.;Chen, Austin D.;Granoff, Melisa D.;Johnson, Anna Rose;Kamali, Parisa;Singhal, Dhruv;Lee, Bernard T.;Fukudome, Eugene Y.
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.336-343
    • /
    • 2019
  • Background Sternal rigid plate fixation (RPF) has been adopted in recent years in high-risk cases to reduce complications associated with steel wire cerclage, the traditional approach to sternal closure. While sternal RPF has been associated with lower complication rates than wire cerclage, it has its own complication profile that requires evaluation, necessitating a critical examination from a national perspective. This study will report the outcomes and associated risk factors of sternal RPF using a national database. Methods Patients undergoing sternal RPF from 2005 to 2016 in the American College of Surgeons-National Surgical Quality Improvement Program were identified. Demographics, perioperative information, and complication rates were reviewed. Logistic regression analysis was performed to identify risk factors for postoperative complications. Results There were 381 patient cases of RPF identified. The most common complications included bleeding (28.9%), mechanical ventilation >48 hours (16.5%), and reoperation/readmission (15.2%). Top risk factors for complications included dyspnea (odds ratio [OR], 2.672; P<0.001), nonelective procedure (OR, 2.164; P=0.010), congestive heart failure (OR, 2.152; P=0.048), open wound (OR, 1.977; P=0.024), and operating time (OR, 1.005; P<0.001). Conclusions Sternal RPF is associated with increased rates of three primary complications: blood loss requiring transfusion, ventilation >48 hours, and reoperation/readmission, each of which affected over 15% of the study population. Smokers remain at an increased risk for surgical site infection and sternal dehiscence despite RPF's purported benefit to minimize these outcomes. Complications of primary versus delayed sternal RPF are roughly equivalent, but individual patients may perform better with one versus the other based on identified risk factors.

Single and Double-row Repair in Rotator Cuff Tears (회전근 개 파열의 일열 봉합술과 이열 봉합술)

  • Park, Jin-Young;Choi, Jin-Hyung;Park, Hong-Keun;Yu, Je-Wook;Seo, Joong-Bae
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.89-95
    • /
    • 2006
  • Purpose: Arthroscopic repair of rotator cuff tears are many techniques that have been developed to improve the initial postoperative strength of the repair. There was a doubt that current arthroscopic cuff repairs using a single row of suture anchors reproduce insufficient area of the anatomic cuff insertion, and concerns about failure of fixation often lead surgeons to limit early motion. Newer technique of double-row repair in arthroscopic treatment may provide initial stronger fixation and more contact with bone at the repair site than single-row repair did. We studied the comparison between clinical outcomes of arthroscopic single- and double-row repair in cuff tears at 1year postoperatively. Materials and methods: We retrospectively analyzed 40 shoulders with single-row repair and 38 shoulders with double-row repair of full-thickness rotator cuff tears between May 2002 and October 2004. Out of total 78 shoulders, 42 (54%) were male patients and 36 (46%) were female patients and the mean age at surgery was 56 years. All patients were diagnosed by physical examination and MRI. At 1year' follow-up after operation, we evaluated with the ASES and the Constant scoring system, and measured muscle power of abduction, internal and external rotation of the affected shoulder then compared with each other. Results: Mean ASES scores and Constant scores in double-row repair group improved more than single-row repair group significantly at 1year postoperatively. Muscle power of abduction and internal rotation, especially abduction power, improved more significantly in double-row repair group than in single-row repair. Conclusion: Arthroscopic double-row repair for the full thickness rotator cuff tear may be a superior technique, which showed better clinical outcomes and restoration of muscle power compared with single-row repair at relatively short period of postoperative follow-up. Restoration of footprint close to normal anatomy by double-row repair seems to play an important role in the recovery of muscle strength.

Detoxification of Glutaraldehyde Treated Porcine Pericardium Using L-arginine & $NABH_4$

  • Kim, Kwan-Chang;Kim, Soo-Hwan;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.99-107
    • /
    • 2011
  • Background: Calcification is the most frequent cause of clinical failure of bioprosthetic tissues fabricated from GA-fixed porcine valves or bovine pericardium. A multi-factorial approach using different mechanisms was recently developed to reduce the calcification of bioprosthetic tissues. The purpose of the present study was to evaluate the synchronized synergism of using L-arginine and $NaBH_4$, compared with ethanol and L-lysine, in glutaraldehyde treated porcine pericardium from the standpoint of calcification and tissue elasticity. Materials and Methods: Porcine pericardium was fixed at 0.625% GA (7 days at room temperature after 2 days at $4^{\circ}C$). An interim step of ethanol (80%; 1 day at room temperature) or L-lysine (0.1 M; 2 days at $37^{\circ}C$) or L-arginine (0.1 M; 2 days at $37^{\circ}C$) was followed by completion of the GA fixation. A final step of NaBH4 (0.1 M; 2 days at room temperature) was followed. Their tensile strength, thickness, and thermal stability were measured. Treated pericardia were implanted subcutaneously into three-week-old Sprague-Dawley rats for 8 weeks. Calcium content was assessed by atomic absorption spectroscopy and histology. Results: L-arginine and $NaBH_4$ pretreatment ($1.81{\pm}0.39$ kgf/5 mm p=0.001, $0.30{\pm}0.08$ mm p<0.001) significantly increased tensile strength and thickness compared with the control ($0.53{\pm}0.34$ kgf/5 mm, $0.10{\pm}0.02$ mm). In a thermal stability test, L-arginine and $NaBH_4$ pretreatment ($84.25{\pm}1.12^{\circ}C$, p=0.023) caused a significant difference from the control ($86.25{\pm}0.00^{\circ}C$). L-lysine and $NaBH_4$ pretreatment ($183.8{\pm}42.6$ ug/mg, p=0.804), and L-arginine and $NaBH_4$ pretreatment ($163.3{\pm}27.5$ ug/mg, p=0.621) did not significantly inhibit calcification compared to the control ($175.5{\pm}45.3$ ug/mg), but ethanol and $NaBH_4$ pretreatment did ($38.5{\pm}37.3$ ug/mg, p=0.003). Conclusion: The combined pretreatment using L-arginine and $NaBH_4$ after GA fixation seemed to increase the tensile strength and thickness of porcine pericardium, fixed with GA. Additionally, it seemed to keep thermal stability. However it could not decrease the calcification of porcine pericardium fixed with GA. $NaBH_4$ pretreatment seemed to decrease the calcification of porcine pericardium fixed with GA, but only with ethanol.

A Clinical Study of Femur Neck Fractures (대퇴 경부 골절의 임상적 고찰)

  • Koo, Hwan-Mo;Ahn, Myun-Whan;Ihin, Joo-Choul
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1990
  • A clinical analysis was done on 23 patients(24 hips) with fracture of the femoral neck, who had been admitted and treated at our Orthopedic department during the period of 4 years, from Jan, 1984 to May 1988. The results were as follows : 1. 23 patients were comprised of 4 males and 19 females, and 11 patients were over 65 years old. 2. 18 cases of 24 cases were due to minor traumas such as slipping down, and for over 65 years old, all cases were due to simple minor traumas, 8 cases were showed a severe osteoporosis, below grade 3 of the Singh's index. 3. 14 cases of 24 cases were displaced subcapital fractures, and 6 cases displaced transcervical fractures. Only 4 cases were the undisplaced transcervical fractures. 4. In treatment of fractures internal fixations after manipulation were performed in 14 cases and primary arthroplasties in 10 cases. Secondary arthroplasties were done in complicated 4 cases of 14 cases treated with internal fixations. 5. Complications after internal fixation were developed in 7 cases out of 14 cases, avascular necrosis in 6, nonunions in 2, pin migrations in 3, and metal failure in 1 case. 6. In 14 arthroplasty immediate surgical fitness of femoral stem were related to late loosening of femoral stem(correlation coefficient r=-0.68, p<0.01).

  • PDF

Physicochemical Properties of Cement Paste Containing Mg(OH)2 Cured by CO2 curing Method (CO2 양생을 이용한 Mg(OH)2 혼입 시멘트 페이스트의 물리화학적 특성)

  • Chen, Zheng-Xin;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.203-210
    • /
    • 2018
  • Corrosion of the rebar is one of the main factors affecting the durability of reinforced concrete in the world which lead to the failure of the reinforced concrete structures. In this research, a new method of fixing $CO_2$ is practiced to improve the carbonation resistance of the concrete. Brucite($Mg(OH)_2$), a kind of common $CO_2$ fixation materials, was added into ordinary Portland cement paste. Samples containing 0%, 5%, 10%, and 15% $Mg(OH)_2$ were exposed to an accelerated carbonation curing regime with 20% concentration of $CO_2$, 60% relative humidity, and a temperature of $20^{\circ}C$ until tested at 3d, 7d, 14d and 28d. After 28d of $CO_2$ accelerated curing, in the paste containing $Mg(OH)_2$, magnesian calcite was detected by SEM-EDX. Meanwhile, the paste containing $Mg(OH)_2$ exhibit the better pore distribution than ordinary Portland cement paste and the compressive strength of the cement paste containing $Mg(OH)_2$ were more than 50Mpa.