• 제목/요약/키워드: Failure of dental implant

검색결과 172건 처리시간 0.026초

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제53권6호
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Oral rehabilitation of Papillon-Lefèvre syndrome patients by dental implants: a systematic review

  • Atarbashi-Moghadam, Fazele;Atarbashi-Moghadam, Saede;Kazemifard, Setare;Sijanivandi, Soran;Namdari, Mahshid
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.220-227
    • /
    • 2020
  • Objectives: Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disorder. These patients lose their teeth at a young age and are in need of prosthetic rehabilitation. The aim of this systematic review was to assess the success of dental implant placement in these patients. Materials and Methods: An electronic search was performed in PubMed Central, Scopus, and Web of Science using the keyword "Papillon-Lefèvre syndrome" AND "dental implant" OR "prosthodontics". Articles reporting implant placement in patients with PLS until July 2019 were included. Results: Assessment of the included 11 articles reporting 15 cases showed 136 implant placements in these patients. Implant failure occurred in 3 patients (20 implants). The peri-implantitis and failure rate was higher in the maxilla. Meta-analysis showed the probability of failure to be 7% (95% confidence interval [CI] 0%-31%) for maxillary implants and 2% (95% CI 0%-9%) for mandibular implants. The follow-up time ranged between 1 and 20 years. Healing after bone graft and implant placement in these patients was uneventful. Conclusion: Dental implants may be a viable treatment option for PLS patients. Implantation can help preserve alveolar bone if the patients' immunological and growing conditions are well-considered and proper oral hygiene and compliance with the maintenance program are continued.

Short-term, Multi-center Prospective Clinical Study of Short Implants Measuring Less Than 7mm

  • Kim, Young-Kyun;Yi, Yang-Jin;Kim, Su-Gwan;Cho, Yong-Seok;Yang, Choon-Mo;Liang, Po-Chin;Chen, Yu-Yal;I, Lee-Long;Sim, Christopher;Tan, Winston;Ser, Go Wee;Yue, Deng;Yi, Man;Ping, Gong
    • Journal of Korean Dental Science
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2010
  • Objective : This prospective study sought to verify the stability of three types of short implants measuring 7mm or less. Materials and methods : Implants measuring 7mm or less were placed in patients at multicenter dental clinics in Korea, China, Taiwan, and Singapore. Initial stability, intraoperative and postoperative complications, crestal bone loss, and survival rate of the implant were prospectively evaluated. Results : The primary stability of a 6-mm implant was lower than that of a 7-mm implant. The marginal bone loss of short implants measuring less than 7mm was minimal. Complications such as wound dehiscence, implant mobility, and peri-implant mucositis developed, and these were associated with initial implant failure. The short-term survival rate of 6-mm implant was 93.7%, and that of 7-mm implant, 96.6%. Conclusion : Short implant for the mandible with insufficient height for the residual ridge can be selectively used. Poor primary stability and wound dehiscence can cause osseointegration failure and alveolar bone loss.

  • PDF

Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석 (Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process)

  • 이승미;장진만;이원식;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

Prognosis following dental implant treatment under general anesthesia in patients with special needs

  • Kim, Il-hyung;Kuk, Tae Seong;Park, Sang Yoon;Choi, Yong-suk;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권3호
    • /
    • pp.205-213
    • /
    • 2017
  • Background: This study retrospectively investigated outcomes following dental implantation in patients with special needs who required general anesthesia to enable treatment. Method: Patients underwent implant treatment under general anesthesia at the Clinic for the Disabled in Seoul National University Dental Hospital between January 2004 and June 2017. The study analyzed medical records and radiographs. Implant survival rates were calculated by applying criteria for success or failure. Results: Of 19 patients in the study, 8 were males and 11 were females, with a mean age of 32.9 years. The patients included 11 with mental retardation, 3 with autism, 2 with cerebral palsy, 2 with schizophrenia, and 1 with a brain disorder; 2 patients also had seizure disorders. All were incapable of oral self-care due to serious cognitive impairment and could not cooperate with normal dental treatment. A total of 27 rounds of general anesthesia and 1 round of intravenous sedation were performed for implant surgery. Implant placement was performed in 3 patients whose prosthesis records could not be found, while 3 other patients had less than 1 year of follow-up after prosthetic treatment. When the criteria for implant success or failure were applied in 13 remaining patients, 3 implant failures occurred in 59 total treatments. The cumulative survival rate of implants over an average of 43.3 months (15-116 months) was 94.9%. Conclusion: For patients with severe cognitive impairment who are incapable of oral self-care, implant treatment under general anesthesia showed a favorable prognosis.

디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복 (Digital impression taking for full-arch implant restoration to a patient with microstomia)

  • 심지석;류재준
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

파노라마방사선사진 지수와 임플란트 실패와의 관계에 관한 연구 (The relationships between panoramic indices and dental implant failure)

  • 조현정;이원진;허민석;안창현;이진구;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2004
  • Purpose: Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. Materials and Methods: A case-control study was designed. Test group (n=42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n=139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. Results: The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Conclusion: Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  • PDF

치과 임플란트와 전신질환과의 연관성에 관한 임상적 고찰 (A Clinical Study on the Relationship between Dental Implant and Systemic Disease)

  • 한양금;윤미숙;김한홍
    • 대한치위생과학회지
    • /
    • 제6권2호
    • /
    • pp.25-35
    • /
    • 2023
  • 연구배경: 전신질환을 보유한 대상자를 위한 임상치과위생사 주도의 치위생관리과정에서의 중요성을 강조하고자 임상적 자료를 근거로 치과 임플란트에 영향을 미치고 있는 전신질환을 파악하고자 하였다. 연구방법: 치과 임플란트에 영향을 미치는 전신질환을 파악하고자 2023년 3월 1일부터 5월 31일까지 문헌고찰을 실시하였으며, 검색 시기는 2000년 1월~2020년 12월까지 국내·외 학술지에 게재된 연구 논문을 대상으로 하였다. 검색에 활용된 국내 database는 학술정보서비스(RISS), 누리미디어(DBpia), 한국학술정보(http://www.papersearch.net;KISS)를 활용하였으며, 국외 database는 Pubmed에서 '치과 임플란트 실패'와 '임플란트와 전신질환' 그리고 Dental implant failures와 Dental implant and systemic disease를 검색하여 전체 383편 중 최종적으로 13편의 자료를 선별하여 분석하였다. 결과: 임플란트의 누적생존률은 평균 94.3%이었으며 실패율은 5.7%이었다. 임상적으로 임플란트와 관련된 전신 질환에 대한 분석결과는 당뇨에 대한 연구가 13편(100.0%)으로 가장 높은 빈도를 차지하였으며 고혈압과 흡연에 대한 연구가 각각 8편(61.5%), 심혈관질환 7편(53.8%), 골관련 질환은 5편(38.5%) 순으로 위험요인이 조사되었다. 그 외 간질환 및 갑상선 이상 그리고 혈액이상 질환과 장기이식 및 감염성 질환 등이 확인되었다. 결론: 임상 치과위생사는 조절되지 않는 전신질환은 임플란트 실패의 위험요인이므로 전신질환이 임플란트에 미치는 영향에 대한 인식과 치위생 사정-판단-수행-평가 등의 주기적인 예방적 치위생관리 과정에서 환자와의 정보공유로 지속적으로 건강한 구강상태를 유지하도록 하여야 할 것이다.

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam;Pil-Jong Kim;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee;Young Ku;In-Chul Rhyu;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • 제54권1호
    • /
    • pp.53-62
    • /
    • 2024
  • Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.