• Title/Summary/Keyword: Fail-Safety system

Search Result 92, Processing Time 0.023 seconds

Development and Implementation of Extension Models for Activity-Based Costing (ABC 확장모형의 개발 및 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.239-250
    • /
    • 2014
  • The purpose of this research is to implement and develop the Economic Cost Driver Size(ECDS) extended model to determine the optimal cash driver size with measurement complexity cost and allocation fail cost. ECDS model can be used to seek both measurement accuracy and time efficiency of the Activity-Base Costing (ABC). The study also develops Activity Priority Number (APN) to evaluate the importance of nonvalue-added activities improvement and to determine the representative cost driver of value-added activities when applying ECDS model. APN consists of Severity Priority Number (SPN), Undetectablitiy Priority Number (UPN) and Occurrence Priority Number (OPN). APN can be obtained from lower-stream activity, current activity, upper-stream activity in terms of hierarchical dependency of SIPOC (Supplier, Input, Process, Output, and Customer). In order to seek both efficiency of invested capital and reduction of overhead cost, the paper proposes the integrated ABC and Economic Value Added (EVA) model using redesigned ABC-based statement of comprehensive income and EVA-based statement of financial position. For a better understanding of the proposed ABC-EVA integrated model, numerical examples are demonstrated in this paper. Cost drivers of ABC and capital drivers of EVA in the proposed model can be used to reduce activity overhead cost from ABC-based statement of comprehensive income and to lessen activity capital charge from EVA-based statement of financial position.

A Proposal for Risk Management according to Organizational Tendency for the Overseas EPC Projects of Public Company (공기업 해외발전 EPC 사업 진출 시 조직성향에 따른 위험관리 방안에 관한 연구)

  • Jang, Hyung Sik;Koo, Il Seob
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.67-76
    • /
    • 2022
  • Power generation construction projects involving large amounts of capital can affect the survival of a company along with huge economic losses in the event of a business failure. In general, private companies are organizations with challenging risk taking tendencies while public companies have a risk averse tendency to avoid risk, so these differences in organizational tendencies make it difficult to respond to risk. In particular, public companies are more likely to fail than private companies because they choose the contradiction of risk picking to enter overseas markets with high uncertainty despite their tendency to risk averse due to the nature of the organization. Therefore, these organizations need risk management techniques that reflect a risk-averse strategy. Accordingly, this paper analyzes the risk management research papers of the existing overseas development EPC business in order to find the risk management techniques related to the organizational tendencies of public companies and proposes "establishing a performance audit system for risk management of the organizational tendencies of public companies" as a way to extract the risk factors through the examples of overseas development projects of public companies and to manage the organizational tendencies of public companies that affect them.

An Analysis on Incident Cases of Dynamic Positioning Vessels (Dynamic Positioning 선박들의 사고사례 분석)

  • Chae, Chong-Ju;Jung, Yun-Chul
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2015
  • The Dynamic Positioning System consists of 7 elements which are namely Power system, Human machine interface, DP Computer, Position Reference System(PRS), Sensors, Thruster system and DP Operator. Incidents like loss of position(LOP) on DP vessel usually occur due to errors in these 7 elements. The purpose of this study is to find out safety operation method of DP vessel through qualitative and quantitative analyze of DP LOP incidents which are submitted to IMCA every year. The 612 DP LOP incidents submitted from 2001 to 2010 were analyzed to find out the main cause of the incidents and its rate among other causes. Consequently, the highest rate of incidents involving DP elements are PRS errors. DP computer, Power system, Human error and thruster system came next. The PRS has been analyzed and a flowchart was drawn through expert brainstorming. Also, the conditional probability has been analyzed through Bayesian Networks based on this flowchart. Consequentially, the main causes of drive off incidents were DGPS, microwave radar and HPR. Also, this study identified the main causes of DGPS errors through Bayesian Networks. These causes are signal blocked, electric components failure, relative mode error, signal weak or fail.

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

The Role of Safety Management Professional Organizations through Industrial Accident Analysis (산업재해분석을 통한 안전관리전문기관의 역할)

  • Deuk-Hwan Kim;Sun-Jae Hwang;Dae-Jin Jo;Jun-Won Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.71-83
    • /
    • 2023
  • Since last year, the government has enforced the 'Act on the Punishment of Severe Accidents, Etc.' (hereafter referred to as the 'Serious Accident Punishment Act'), which punishes business owners and business managers who fail to fulfill their duty of safety measures with 'imprisonment of one year or more' and the Occupational Safety and Health Act. Based on this, various occupational safety and health policies were developed, including the operation of a system related to entrusting the work of safety managers. Despite these efforts, the effect of implementing the Severe Accident Punishment Act is a groundbreaking change in the current disaster prevention policy, which has increased by 0.02%P and 0.03‱P, respectively, from the previous year to 0.65% of the total accident rate and 1.10‱ of the death rate per 10,000 people as of 2022. As the need emerged, attention was paid to 'collaboration and governance with safety management institutions' in the 'Severe Disaster Reduction Roadmap' announced by the Ministry of Employment and Labor in November 2022. In this study, a meaningful result was derived by comparing and analyzing the industrial accident status of workplaces entrusted by "A" safety management institutions with the national average based on the industrial accident survey table, and the types of industrial accidents that occurred in consigned workplaces were selected as intensive management targets. The policy direction for industrial accident prevention was established. It is necessary to develop safety management work manuals based on the results of this study, expertise, discover best cases of risk assessment and develop guides, and educate and train consigned workers. In addition, it suggests that the government's guidance and supervision are needed to advance the professionalism of safety management entrusted tasks, and that safety management institutions should strengthen their roles and functions for preventing and reducing industrial accidents. However, due to difficulties in disclosing information of specialized safety management institutions, the limitation of the provision, collection, and viewing of research-related data to "A" specialized safety management institutions remains a limitation of the research. It seems likely that more thorough research will be conducted.

A Design of Group Signature Based Vehicle Payment Protocol to Ensure Vehicle Anonymity (차량 익명성을 보장하는 그룹 서명기반 차량용 결제 프로토콜 설계)

  • Chung, Myung-woo;Kim, Seung-joo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.4
    • /
    • pp.753-773
    • /
    • 2019
  • CV(Connected Vehicle) technology provides safety-related services and user convenience-related services to vehicle. Safety-related services can cause privacy problem by continuously transmitting vehicle information to nearby vehicles or base stations. Therefore, safety-related services should provide vehicle anonymity for privacy protection. However, if convenience-related services such as payment services fail to provide vehicle anonymity, driver information related to safety-related services may also be leaked. In this paper, we design a payment protocol based on ECQV(Elliptic Curve Qu-Vanstone) impicit certificate and group signature that provides BU-anonymity and traceability. The proposed payment protocol makes it impossible to track vehicles from payment transactions history by separating roles of payment system components. Moreover, we define the security requirements that the vehicle payment protocol must satisfy and show that the protocol satisfies the requirements.

A STUDY ON THE FATIGUE LIFE PREDICTION OF GUIDEWAY VEHICLE COMPONENTS (안내궤도 차량 부품의 피로 수명 예측에 관한 연구)

  • Lee, Soo-Ho;Park, Tae-Won;Yoon, Ji-Won;Jeon, Yong-Ho;Jung, Sung-Pil;Park, Joong-kyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.997-1002
    • /
    • 2007
  • A guideway vehicle is used in automobile, semiconductor and LCD manufacturing industries to transport products efficiently. Since the operating speed of the guideway vehicle should be increased for maximum productivity, the weight of the vehicle has to be reduced. This may cause parts in the system to fail before the life of the system. Therefore estimation of the fatigue life of the parts becomes an important problem. In this study, the fatigue life of the driving wheel in the guideway vehicle is estimated using a S-N curve. To obtain the fatigue life of a part, the S-N curve, load time history applied on a driving wheel and material property are required. The S-N curve of the driving wheel is obtained using the fatigue experiment on wheels. Load time history of the wheel is obtained from multibody dynamics analysis. To obtain the material properties of the driving wheel, which is composed of aluminum with urethane coating, a compression hardware testing has been done with the static analysis of the FE model. The fatigue life prediction using computational analysis model guarantees the safety of the vehicle at the design stage of the product.

  • PDF

Structural reliability index versus behavior factor in RC frames with equal lateral resistance

  • Mohammadi, R.;Massumi, A.;Meshkat-Dini, A.
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.995-1016
    • /
    • 2015
  • The reliability or the safety index is a measure of how far a structure is from the state of collapse. Also it defined as the probability that a structure will not fail in its lifetime. Having any increase in the reliability index is typically interpreted as increasing in the safety of structures. On the other hand most of researchers acknowledged that one of the most effective means of increasing both the reliability and the safety of structures is to increase the structural redundancy. They also acknowledged that increasing the number of vertical seismic framing will make structural system more reliable and safer against stochastic events such as earthquakes. In this paper the reliability index and the behavior factor of a numbers of three dimensional RC moment resisting frames with the same story area, equal lateral resistant as well as different redundancy has been evaluated numerically using both deterministic and probabilistic approaches. Study on the reliability index and the behavior factor in the case study models of this research illustrated that the changes of these two factors do not have always the same manner due to the increasing of the structural redundancy. In some cases, structures with larger reliability index have smaller behavior factor. Also assuming the same ultimate lateral resistance of structures which causes an increase to a certain level of redundancy can enhance behavior factor of structures. However any further increase in the redundancy of that certain level might decrease the behavior factor. Furthermore, the results of this study illustrate that concerning any increase in the structural redundancy will make the reliability index of structure to be larger.

A Study on the Feasibility of Installing Solar Auxiliary Power for Small Fishing Boats (태양광 보조전원을 설치한 소형선박의 타당성 연구)

  • Yoon, Kyoungkuk;Jeon, Hyeonmin;Hwang, Junyoung;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • The South Korean fishing industry is experiencing a rapid growth owing to an increase in its leisure-fishing population. Consequently, fishing boats weighing 9-10 [ton] have also been increasing. Current fishing boats operate their essential equipment by switching their engines with batteries to reduce the cost of gas and engine noise. However, stranding incidents have been increasingly recorded annually, in which boats fail to start owing to discharged batteries, and these incidents can lead to serious casualties. This study proposes the installation of a solar auxiliary power system to safeguard fishing boats, particularly those weighing between 9-10 [ton]. The feasibility of securing space for the solar auxiliary power of boats under consideration was verified. To examine the application of solar power, this study calculates the load necessary to operate it for fishing and models such a system using an electricity analysis program The modeled system, which applies the monthly horizontal solar insolation, validated the adoption of a solar auxiliary power in fishing boats.

Study on Design of Rail Level Crossing System for Preventing from Non-Alarming Status Caused by Track Shunting Sensibility Errors (레일 단락감도 불량으로 발생하는 무경보 예방을 위한 건널목보안장치 설계)

  • Jang, Dong-Wan;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.160-166
    • /
    • 2010
  • Railroad level crossing systems are used to prevent train from collisions by informing pedestrians and vehicles of approaching trains on the level crossing. The current detection systems mostly use track-based electrical circuits to detect approaching trains. The making and breaking of the circuit when the train wheel passes along the track sends a signal to barriers that restrict access to the track. Unfortunately, this track-based signal system is vulnerable to malfunctions in certain situations. If the rail becomes rusted due to moisture, weather conditions, or infrequent use, the electrical circuit detection system could fail. Such a failure could lead to a train-vehicle or train-pedestrian collision. This paper suggests a replacement of the electrical circuit-based system with an infrared detection system. The research shows that an infrared detection system improves safety by reducing the frequency of detection failure of the alarming circuit to system.