• Title/Summary/Keyword: Facility upgrading

Search Result 28, Processing Time 0.023 seconds

A Study on Developing the Standardized Index of Evaluation for Upgrading the School Facilities (학교시설개선을 위한 평가지표개발에 관한 연구)

  • Song, Byung-Joon;Kim, Young-Suk;Chu, Beom
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.260-270
    • /
    • 2012
  • The demographic and environmental changes such as the decrease of the population growth rate and the increase of the population of the senior citizens, which become issues of the modern society, are bringing numerous changes of many aspects like national economy, community, and culture. These social phenomena give impacts on the school facilities as well. Thus owing to the decrease of the number of the students, the number of the newly constructed schools has been decreased drastically, and moreover the merger of the schools cause many schools to be default. Meanwhile, the school facilities have been expanded into the functions of the local community centers, and the various educational activities demand the diversity and flexibility of the spaces. These factors add more burdens to the current schools. Therefore the school facilities are needed to adopt a flexible and relevant change necessary for using the spaces in accordance with the changed needs of the times, and are needed to reinvented continuously not to limit the educational and social activities because of the degradation of the school facilities. Yet because there are no proper criteria for doing the task, problems related to the relevance of the task and the unnecessary investment are raised. So through this study I tried to demonstrate the standardized index in terms of the sequential priority of upgrading the facilities among the schools.

  • PDF

Estimation of Willingness-to-pay for Rehabilitation and Upgrading of Reservoirs in Protecting Against Natural Disasters and Dam-Break (재해·재난 예방을 위한 저수지개보수사업의 지불의사금액 추정)

  • Park, Sung Kyung;Lim, Cheong Ryong;Han, Jae Hwan;Chung, Won Ho
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.139-153
    • /
    • 2018
  • This study analyzes the economic effect of rehabilitation and upgrading of reservoirs as a prevented method against natural disasters under recent abnormal weather conditions and dam-break. For the analysis, we divide the purpose of rehabilitation and upgrading of reservoirs into the stable supply of rural water under uncertain weather conditions and the prevention of collapse due to the aging of the reservoir. We measure the economic effect of rehabilitation and upgrading of reservoirs by estimating the resident's willingness-to-pay for the project through Contingent Valuation Method(CVM). The result shows that distributions of willingness-to-pay to prevent natural disasters and dam-break are similar to each other. About 66% of the residents in sample regions are willing to pay for the project. The resident's willingness-to-pay to protect natural disasters and dam-break are 32,250 to 46,147 won and 28,427 to 47,308 won respectively on average for all sample regions. The comparison of willingness-to-pay by type of regions shows that paddy field areas are the highest followed by facility cultivation areas and urban areas. In addition, total expected value of the projects calculated based on the resident's willingness-to-pay for paddy field areas and facility cultivation areas are much larger than actual project costs. This implies that rural residents are fully aware of the importance of the project to prevent natural disasters and dam-break and are willing to pay for additional costs if needed.

Highway bridge live loading assessment and load carrying capacity estimation using a health monitoring system

  • Moyo, Pilate;Brownjohn, James Mark William;Omenzetter, Piotr
    • Structural Engineering and Mechanics
    • /
    • v.18 no.5
    • /
    • pp.609-626
    • /
    • 2004
  • The Land Transport Authority of Singapore has a continuing program of highway bridge upgrading, to refurbish and strengthen bridges to allow for increasing vehicle traffic and increasing axle loads. One subject of this program has been a short span bridge taking a busy highway across a coastal inlet near a major port facility. Experiment-based structural assessments of the bridge were conducted before and after upgrading works including strengthening. Each assessment exercise comprised two separate components; a strain and acceleration monitoring exercise lasting approximately one month, and a full-scale dynamic test carried out in a single day. This paper reports the application of extreme value statistics to estimate bridge live loads using strain measurements.

A Study on the Voltage Upgrading of Transmission Lines using Polymer Insulation Arm (폴리머 절연암을 이용한 송전선로 전압 승압에 관한 연구)

  • Lee, Won-Kyo;Lee, Jung-Won;Kang, Yeon-Woog;Lee, Dong-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.870-878
    • /
    • 2009
  • The large increase in the use of electricity has resulted in an ever-growing electric power demand. It has created the need for the construction of power transmission facility located close to the load centers and it also has to require wide right-of-way and large lots, that are not always available, for especially the installation of the towers. The difficulties in acquiring right-of-way have put pressure on energy companies to either upgrade a line on an existing right-of-way to higher voltage or build a new line on a narrow right-of-way. This paper presents the design of a compact tower with polymer Insulation arm, in order to reduce the separation between phases. the compact tower can be built on a narrow right-of-way. the compact tower can be designed based on 345 kV Tower regarding electrical clearances and right of way, therefore the conventional 154 kV Tower can be upgrading transmission line voltages have moved to 345 kV levels.

Dose Determination in the IR-221 Gamma Facility Using a Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 IR-221의 선량 평가)

  • Lim, Ik-Sung;Kim, Ki-Yup;Roh, Gyu-Hong;Lee, Chung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • This study is performed to evaluate the dose rate and to analyze the dose distribution of the gamma irradiation facility (IR-221) by using a Monte Calro simulation, which is helpful of upgrading the radiation processing qualification. Monte Cairo simulation is performed by MCNP4B code. Dose rates were measured at total 369 points with alanine dosimeters to compare the calculation results and the measurements data. The results have shown that the MCNP4B code is very useful to determine the dose distribution of the IR-221 gamma irradiation facility, as the calculation dose rate is within about ${\pm}5%$ of the measurement data. Dosimetry about the gamma irradiation facility usually needs enormous manpower and time. However Monte Cairo calculation method can reduce the tedious dosimetry jobs and improve the irradiation processing qualification, which will probably contribute to obtain the reliability of the irradiation products.

Programs for Higher Efficiency of Private Sector Investment in Educational Facilities -With Focus on Combining of Public Service Facilities- (학교시설 민자 사업의 효율화 방안 -공공서비스 시설의 복합화 중심으로-)

  • Kang, Hyun-bin;Lee, Jae-Lim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.8 no.1
    • /
    • pp.11-22
    • /
    • 2009
  • School is a basic and the most fundamental facility of city planning just like other basic public facilities including the village office. Every plan is established on the basis of school. However, the problems such as the population reduction resulting from the nuclear family-zation and low birth rate, employment and welfare of the aged people resulting from "the old aged society", and the infant nursing and education resulting from a rapid increase of the working couples become notable and accordingly more requirements are being made. Reflecting this trend, the concept and operation system should be changed. Up to now, the BTL projects of the educational facilities are gaining a reputation of being efficient in terms of national budget running, but at the same time receiving negative reputation in terms of budget saving under the civil creativity and efficiency. Through upgrading the private sector investment projects into the BTO+BTL system and further into the BTO(Build Transfer Operate), we can accomplish the original goals of the private sector investment projects, and can make the education budget operation more efficient, and can greatly improve the education environments. However, we should not underestimate in this process that these facilities should not negatively affect the education environments. In any situation, the owners of schools are students.

  • PDF

Comparison of Fault Current Limiting Characteristics According to Facility in Power System (전력계통의 사고전류 저감 설비별 특성 비교)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

Quality Improvement and Application increase of Framework Data in the Facility Area (시설물분야 기본지리정보 품질 향상 및 활용 증대 방안)

  • Ru Ji-Ho;Heo Min;Lee Hyun-Jik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.1
    • /
    • pp.79-88
    • /
    • 2006
  • The facility area occupies approximately 50% of the topographic landmarks playing an important role in the utilization of geographical information in various fields, and requires more up-to-date information than the framework data of other areas. However, the expression mode in the 1:5000 digital map, which is a primitive data used for the preparation of framework data in the facility area, limits the description of the information on buildings, and its revision/renewal term of 5 years makes it far from up-to-date or accurate. Therefore, this study aimed to analyze the problems and quality deteriorating factors that may occur in establishing the framework data on the basis of existing establishment process of them in the facility area, and improve the qualify of the framework data in facility area by upgrading the methods of quality improvement. Expanding the information on attributes and improving the accuracy of locations were proposed as ways to increase the degree of utilization of the framework data in the facility area. And as the methods of expanding the information on attributes, it was proposed to improve the accuracy of the information on attributes for the framework data in the facility area using the information on attributes in the 1:1000 scale maps, and also to diversify the information on attributes in connection with the LMIS and AIS. To improve the accuracy of the locations, analyses were made with the potential problems that may occur in the establishment process through an experiment on the framework data in the facility area based on 1:1,000 digital map, and the results were used to present an improved, optimum process.

Upgrading Acoustic Chamber and Verification Test (음향 환경시험 챔버 성능 개선 및 검증 시험)

  • Eun, Hee-Kwang;Im, Jong-Min;Moon, Sang-Moo;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.60-65
    • /
    • 2007
  • Acoustic chamber was developed for verifying the performance of a satellite under the launch condition on the Space environment test department. As the size of a satellite is increased the extension of existing facility is required. This paper encompasses the following items; redesign of components in acoustic chamber, product procedures of them and review of the test for the components of satellite in the upgraded acoustic chamber.

  • PDF

Restructuring Primary Health Care Network to Maximize Utilization and Reduce Patient Out-of-pocket Expenses

  • Bardhan, Amit Kumar;Kumar, Kaushal
    • Asian Journal of Innovation and Policy
    • /
    • v.8 no.1
    • /
    • pp.122-140
    • /
    • 2019
  • Providing free primary care to everyone is an important goal pursued by many countries under universal health care programs. Countries like India need to efficiently utilize their limited capacities towards this purpose. Unfortunately, due to a variety of reasons, patients incur substantial travel and out-of-pocket expenses for getting primary care from publicly-funded facilities. We propose a set-covering optimization model to assist health policy-makers in managing existing capacity in a better way. Decision-making should consider upgrading centers with better potential to reduce patient expenses and reallocating capacities from less preferred facilities. A multinomial logit choice model is used to predict the preferences. In this article, a brief background and literature survey along with the mixed integer linear programming (MILP) optimization model are presented. The working of the model is illustrated with the help of numerical experiments.