Development of an Improved Inspection System for Slopes adjacent to Educational Facilities (개선된 교육시설 인접 사면 점검체계 구축)

  • Ko, Jun-Young;Lee, Joon-Kyu;Park, Ku-Byoung;Lee, Byoung-Ho;Kim, Jae-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.28 no.4
    • /
    • pp.3-10
    • /
    • 2021
  • This study presents an improved inspection system for slopes adjacent to educational facilities. For this, field investigations for 5 schools and 3 universities were performed to analyze the engineering stability of infrastructures, which ensure the safety of students and educational officers. Educational laws and the relevant enforcement are reviewed to understand the problems of current laws and enforcement. The results reveal that the engineering measures and reinforcement are required for the slopes of 36%. Also, the improvement of social awareness and regular inspection is needed to maintain the educational infrastructures. The suggested inspection system includes the fundamental and detailed checklists and guidance for non-engineering specialists.

Database Construction Plan of Infrastructure Safety Inspection and In-depth Inspection Results (사회기반 시설물의 안전점검 및 정밀안전진단결과 DB 구축방안 연구)

  • Ryu, Jong Mo;Shin, Eun Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.133-141
    • /
    • 2014
  • This study was carried out to establish the database system by using the safety inspection and in-depth inspection results for infrastructures such as bridges, tunnels, dams, and water supplies. A classification system of each facility was proposed by standardizing items for inspection & diagnosis in order to automatize work process. Also, it justifies data structure based on database from pre-investigation to field survey, evaluation of facilities, and report making. In addition to this, it suggests improvement plans of relative regulations and guidelines such as Facility Management System(FMS), operational regulation, and inspection detailed guideline to make inspection result database of infrastructures which can be used effectively.

Estimation of National Loss Expenses to Insufficient Safety Inspection and Precision Safety Diagnosis (부실 정밀점검 및 정밀안전진단의 국가적 손실비용 추정)

  • Ha, Myung-Ho;Park, Jong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.246-253
    • /
    • 2010
  • National major facilities have been rigorously investigated using regular safety inspections and precision safety diagnosis since the Special Law for Facilities Safety Management was made in 1995. However, the process of safety inspection and precision safety diagnosis could be doubted due to intervention of facility owner for safety level evaluation, competition to obtain low price order, and low technical skills of inspection companies. Although the management processes for evaluating the inspection companies were used for several years, the process should continue to improve in the safety inspection field. This study analyzed the recent evaluation system and the ratios of insufficient inspection. Estimation of national loss expenses to the insufficient safety inspection was investigated to recognize the necessity for the improvement of facility inspection process and evaluation system.

A Study on Management Body Consciousness for Managing Facility Safety Inspection and Diagnosis (시설물 안전 점검 및 진단 실시에 대한 관리주체 의식에 관한 연구)

  • Kim, Hak-Eung;Jung, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.19-27
    • /
    • 2008
  • Since 1995, the facility of class 1 and 2, classified by law had been subject to system of post maintenance management where periodic safety inspection and diagnosis to identify any problems and to take appropriate measures as a matter of urgency. Although the standards and systems had been revised many times for continuous improvement due to surrounding environmental factors, the technical factors and other factors for improvements, continuous researches and efforts are needed to ensure even higher effectiveness. Furthermore, the consciousness of the management body that executes and implements such improvements for facility management is most important. Therefore in this study, through such analysis, more realistic management consciousness review was performed. Also the direction for improvements is proposed, to carry out more effective facility safety management systems implementation.

The inspection and seismic design method of electrical facility instated in the building (건축물에 시설되는 수변전설비 내진설계 및 검사 방법에 관한 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Kang, Min-Hee;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.332-335
    • /
    • 2009
  • Incase of not considered seismic design at transformer vault which is made of many informant electrical facility, facility is damaged, electrical fire breaks out and second damage is able to break out at generating earthquake. But seismic design yet is not applied to at transformer vault in the country. Regard to seismic design method of electrical facility installed in the building internal, we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility. reliability inspection plan for seismic design and construction of electrical facility

  • PDF

Effects of Regular Inspection Facility Standards Improvement on Particulate Matter (PM10) Emissions (정기검사 시설기준 개선이 입자상물질(PM10) 배출에 미치는 영향)

  • Choi, Soungkyu;Kim, Yongdal;Lee, Jaeyoung;Kim, Hogyeong;Noh, Kiseong;Park, Jungsoo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.1
    • /
    • pp.36-39
    • /
    • 2019
  • The particulate matter that was emitted always come up by atmospheric environmental problem. Running on the road vehicles must have regular inspection at regular period and make sure the emissions of exhaust gases exceed the legal standards. Emission test for the atmospheric environment, but it is not free from the particulate matter. Currently, emission test of vehicle inspection is divided into regular inspection and close inspection. Regular inspection and close inspection differ not only the method of emission test, but also the facility standards that must have for this inspection. According to the "Regulations on the Implementation of Comprehensive vehicle Inspection, etc.", close inspection must have trapping device that is trap particulate matter by emission test to vehicle. However, regular inspection is different. Regular inspection do not specify any criteria for trapping facilities. Therefore, this study is confirm how to prevent the emission of particulate matter to the atmosphere during the year when mandatory trapping facilities are required to trapped particulate matter in the regular inspection.

A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구)

  • Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

Assessment of Degree and Safety Inspection Based on Maintenance Level in Domestic Youth Training Facility (국내 청소년시설 대상 유지관리기반 안전점검 및 안전성 평가 연구)

  • Lee, Jeong-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • Recent the number, size and accident on Youth Training Facility have increased annually. Also, the discussion and interest relation to safety and maintenance of youth culture and education. This study asserts the necessity and importance of present condition and characteristic based on Youth Training Facility in domestic. Therefore, Results of this study, it is appeared that very vulnerable to improve safety and maintenance in them. Accordingly, The purpose of this study is to investigate the current status for the whole youth facilities. second it estimate on main damage and defect of them for the period four years.

Research on the Safety Inspection Plan of Outdoor Advertising Safety Using Drone (드론을 활용한 옥외광고물 안전도 검사 방안에 관한 연구)

  • Jeong, Hee-Jeong;Lee, Suk-Hyung;Chang, Hye-Jung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.530-538
    • /
    • 2020
  • Safety inspections of outdoor advertisements are conducted to determine the aging status, specifications, and compliance with design documents. Regular inspections are conducted on outdoor advertisements from a safety perspective, as they not only undermine the aesthetic elements of the city but also could cause falls on roads or pedestrian paths. However, the current safety inspection methods are at risk of various accidents during the inspection advertisements on the outer wall of the building. And it is difficult to conduct in-depth inspections on them if they are fixed to the elevation of the building. Furthermore, there also is a risk of safety accidents, such as advertising structures falling onto a pedestrian path. Therefore, this paper aims to enhance the safety inspection system of outdoor advertisements using drones. This paper also intends to propose measures for facility inspection history management such as safety inspection cycle, maintenance, and removal of signboards.

Improvement Plans for the Safety Management System of Amusement Facilities (유기시설의 안전관리체계 개선방안에 관한 연구)

  • Lee, Myeonggu;Kim, Sunmi;Lee, Heejung;Jo, Jaeyong;Han, Seokyung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.3
    • /
    • pp.69-75
    • /
    • 2015
  • In recent society, great and small accidents have happened frequently, so the demands for safety have increased. As numerical increase of tourists who use the amusement facilities, many accidents owing to amusement facility has arisen. The goal of this study is that suggests the improvement plans for the safety management system of amusement facilities. In order to achieve the goal of study, legislations, industrial scale, accident situation, and others relating to amusement facility business were considered in a lot of ways. From a series of study results, improvement plans are suggested for safety inspection, accident compensation insurance, accident investigation, and others relating to amusement facility business.