• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.024 seconds

Semi-Rig, Anti-condensation design on steel surface in pontoon area (Semi-Rig, Pontoon 구역 표면 결로 예방 설계)

  • Seo, Dong-jae;Park, Sang-un;Noh, Joung-hwan;Shim, Hak-mu
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.105-108
    • /
    • 2017
  • Condensation is one of the common issues which we can easily see in everyday life. For example, the surface of glasses with cold water is easily moisturized. This wet surface gives us uncomfortable feeling and is sometimes dangerous because it is slippery. As the safety on working space is one of the most important issue on offshore project, condensation is also important matter to take care of with precaution. Since the bottom of vessel or offshore facility is submersed in the water, the risk of having condensate on the steel surface is getting higher because sea water temperature is normally lower than ambient temperature. And if there is any electric equipment or person working in that space, condensation is normally not allowed. The pontoon of semi-submersible drilling rig is such a space which is submersed, with electric and mechanical equipments and person working periodically. To prevent condensation in pontoon, study was conducted by checking several cases.

  • PDF

A Study on the Promotion of the Availability of Multipurpose School Auditoriums for Use by Local Community - Based on Case Studies of Primary, Middle and High Schools in Busan - (학교시설 다목적강당의 지역주민이용 활성화 방안에 관한 연구 - 부산시내 초.중.고교 중심으로 -)

  • Bang, Taek-Hoon;Kim, Ki-Hwan
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.3
    • /
    • pp.56-65
    • /
    • 2006
  • The multipurpose auditoriums in schools are the center of local community and the places of their life-long education. The multipurpose auditoriums are to be open and made available for use by local public as far as it does not interfere with the education of the schools. However, most of them are not open to public on the pretext of management problems while demands of local communities for the opening of the facility is rising. The role of the multipurpose auditorium as the place of physical training and its maximum availability to local community have be taken into account of from its design stage. The location of the auditorium itself has to be close to the main entrance of the school for easy access, its facilities located in one common area, their management and maintenance scheme adopted appropriately but legally, and then security and safety measurement have to be devised. Also, more studies are necessary to propose detail regulations for local sports facilities and to develop their interrelationship and network, in connection with sophistication of school facilities and BTL system.

Housing Improvement Elements Depended on the Analysis of Urban Residents' Perceived Korean Housing Quality Related to Mental Health (거주자가 지각한 정신건강 관련 주거의 질 분석에 기초한 주거 개선요소)

  • Choi, Byungsook;Park, Jung-A
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.189-197
    • /
    • 2013
  • The purpose of the study was to analyze the improvement elements depended on housing quality measurement tool related to mental health. The data for the analysis was collected through questionnaire survey method from November 1, 2012 to January 17, 2013, and the sample consisted of 720 respondents living in single detached houses, multi-families detached houses, apartments, and town houses in 4 cities, Seoul, Busan, Daejeon, and Kwangju. The data were analyzed using descriptive statistics. The results of improvement elements are as follows: 1) Pedestrian-threaten street from cars in physical safety 2) A secluded or dark spot and fear of walking at night in social security, 3) Indoor noise, outdoor noise, and evidence of abandoned trash heap/bottle in neighborhood in health & sanitation, 4) Illegal parking and heating control system in facility convenience, 5) Extra kitchen, number of bathrooms, and community spaces in space convenience, 6) Openness and spaciousness of indoor room, and satisfaction of house and neighborhood in comfort, 7) Management common/sharing space in maintenance, 8) Energy saving facility and environment friendly materials use in sustainability, 9) Burden on housing cost, asset value on house, and school district in economic value, 10) Reflection of residents style, surrounding building's number of layers, and neighborhood appearance of preference in housing environment image.

A Study on Status of Use and Facilities importance level evaluation of Neighborhood Park in Industry Complex on the rural - With Special Reference on 4 Local Industry Complex of Cheonan City (농촌 산업단지 내 근린공원의 이용실태 및 시설 평가 연구 - 천안 제 4지방산업단지 내 근린공원을 중심으로 -)

  • Yun, Yo-Sun;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.1
    • /
    • pp.65-72
    • /
    • 2013
  • Neighborhood park has the multiple functions toward quantitative and qualitative improvement of quality of citizen's life. This study is about neighborhood park in 4 Local Industry Complex of Cheonan City. Through this study has intended to analyze the status of use and the importance level of facilities. To reach this goal, this study has analyzed the general information, use and importance level of users through such statistical methods as frequency analysis, regression analysis and reliability analysis. As a result, users has the speciality in the neighborhood park in industry complex. Break area or facilities for the workers should be installed. Not end once installed, but continually improved and more efficient management of park facilities will be made. Also, importance of facilities analysis has the higher in normal or importance. Management and cleanliness is especially higher in importance. Importance for the overall facility was affecting in order the facility design, management, safety, installation number.

Analysis of Gamma Radiation Fields in the MAPLE-X10 Facility Associated with Loss-of-Pool-Water Accident Conditions (LOSS-OF-POOL-WATER 사고시 연구용 원자로 MAPLE-X10 시설에서의 감마 방사선장 해석)

  • Kim, Kyo-Youn;Ha, Chung-Woo;I.C. Gauld
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.63-72
    • /
    • 1989
  • An analysis for the gamma radiation fields in the research reactor MAPLE-X10 facility has been peformed under the assumption of partial loss of reactor and service pool water to assess the safety from the view point of design. Four photon source terms considered in the analysis were calculated using the ORIGEN-S code. Gamma dose rate calculations over the reactor and service pools during the water-loss accident conditions were performed using QAD-CG code. MCNP code (Monte Carlo Neuron and Photon Transport code), also, was used to assess the scattered radiation fields away from the pools, which is appropriate for calculating the scattered photon dose rates outside of the solid angle subtended by the source and pool walls.

  • PDF

A Study on the Architectural Planning of the Ward in Infectious Disease Hospitals (감염병 전문병원의 병동부 건축계획에 관한 연구)

  • Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • Purpose: This study analyzed the architectural planning factors of the ward in infectious disease hospitals, such as functional unit planning, ward configurations, spatial compositions & circulation, and detailed architectural planning. Through these, the facility guidelines of infectious disease hospitals are summarized, focusing on the differences from the wards of non-infectious hospitals. Methods: This study was conducted by literature review of research reports, papers, design cases, and guidelines, based on the experiences of field surveys for infectious disease hospitals. Results: The result of this study can be summarized into a few points. 1) Infectious disease hospitals need to establish an operation plan with the concept of continuity of care, as an extension of existing facilities. 2) The types of ward configuration for infectious disease hospitals has many variables, so an appropriate type should be selected according to the hospital's operating policy. 3) Various spatial composition types of the ward can be planned by the arrangement of traffic cores and areas of patient groups. At this time, the main planning considerations are safety, efficiency, and comfort. 4) As elements of the detailed plan, It is necessary to consider the types & dimensions of patient rooms, the relationships between nursing stations & sub-stations, and supplementations of medical support functions & convenience facilities. Implications: Since there are many differences in function from the ward of non-infectious hospitals, appropriate facility guidelines for infectious disease hospital are required.

Analysis of Seasonal Airborne Radon Concentration Characteristics in Public-Use Facilities

  • Young-Do KIM;Woo-Taeg KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the characteristics of airborne radon concentration by season in public-use facilities in South Korea. Research design, data and methodology: The data is provided by the public data portal, and public-use facilities nationwide where radon in the air is measured are specialized sanatorium for senior citizens, libraries, childcare facilities, postpartum care centers, medical institutions, funeral halls, underground shopping malls, and underground subway stations. Results: The facility with the highest radon concentration in public-use facilities was childcare facilities with an average of 50.2 ± 21.7 Bq/m3, while the average of medical institutions was the lowest at 24.8 ± 5.7 Bq/m3. The season with the largest difference in average radon concentration between childcare facilities and medical institutions was in the order of fall (28.6 Bq/m3), followed by winter (28.1 Bq/m3), spring (23.0 Bq/m3), and summer (22.0 Bq/m3). Conclusions: The main concentration levels of each public-use facility shown in this study are all below domestic and international standards, but there is a significant concentration difference between facilities. By season, winter showed the highest average concentration (40.6 ± 21.3 Bq/m3) and summer showed the lowest average concentration (23.8 ± 14.0 Bq/m3).

Riser Configuration Design for a 15-MW Floating Offshore Wind Turbine Integrated with a Green Hydrogen Facility

  • Sung-Jae Kim;Sung-Ju Park
    • Journal of Ocean Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.137-147
    • /
    • 2024
  • Green hydrogen presents a sustainable and environmentally friendly solution for clean energy production and transportation. This study aims to identify the optimal profile of green hydrogen transportation risers originating from a floating offshore wind turbine (FOWT) integrated with a hydrogen production facility. Employing the Cummins equation, a fully coupled dynamic analysis for FOWT with a flexible riser was conducted, with the tower, mooring lines, and risers described using a lumped mass line model. Initially, motion response amplitude operators (RAOs) were compared with openly published results to validate the numerical model for the FOWT. Subsequently, a parametric study was conducted on the length of the buoyancy module section and the upper bare section of the riser by comparing the riser's tension and bending moment. The results indicated that as the length of the buoyancy module increases, the maximum tension of the riser decreases, while it increases with the lengthening of the bare section. Furthermore, shorter buoyancy modules are expected to experience less fatigue damage, with the length of the bare section having a relatively minor impact on this phenomenon. Consequently, to ensure safety under extreme environmental conditions, both the upper bare section and the buoyancy module section should be relatively short.

Analysis on the Actual Environmental Conditions of Domestic and Oversea Police Detention Facilities (국내외 경찰서 유치시설의 환경 실태 분석)

  • Cho, Hyeonmi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.339-349
    • /
    • 2013
  • The primary purpose of this research was to set up the standard guidelines for the planning of interior architectural environments of the detention facilities at the Korean Police Stations. By visit-studying the actual interior environmental conditions of 5 different kinds' domestic Correcting Facilities and 5 domestic police detention facilities and 2 foreign police detention facilities, comparing them to the existing Korean correctional institutions' cell facilities, that the strengths and weaknesses had been analyzed to extract the main concepts and the planning scheme for the Standard Korean Police Detention Facilities. By reserching the National human Right Commitee's Anual Reports, three different indexes were picked out for those analysis : the Environmental control index, the Detention Service support index, the Environmental support index. These three indexes will be used as Key factors for the planning of interior architectural environments of the detention facilities at the Korean Police Stations.: (1)the Environmental control index to establish the Space Program, the Spatial Hierarchy and the horizontal & vertical Security Blocks, (2)the Detention Service support index for the central Environmental Control & Security System, the Secured Privacy for both detainees & police offices, (3)the Environmental support index for the gender-respected segregation of cell zones, the psychological & physical safety design factors, the construction standards of all rooms in a detention facility. The result of this study should be used as the guidelines for "The Standard Plans and Regulations for the Korean Police Detention Facilities" to respect fundamental human rights.

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.