• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.03 seconds

A Study on Certification Method of Health and Barrier Free Environment by the BIM for Aged Person - With Sanitary Facilities of Elderly Housing Facility - (노인 주거시설의 위생공간을 중심으로 고령자의 건강과 무장애 생활환경을 위한 인증 방법에 관한 연구 - BIM기반 설계 및 응용을 통한 방법을 중심으로 -)

  • Hong, Sa-Chul;Paik, Jin-Kyung;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.13-24
    • /
    • 2017
  • Promoting barrier-free living environments is necessary in residential facilities on which senior citizens rely most of their lives. Safety of elder people can be reassured by a certification system based on the existing barrier-free certification program in public facilities. The range of certification does not cover all living area, but is limited to the bathroom, which is a sanitary space. Given the nature of BIM modeling, an existing multi-family building was selected and modeled, as the certification process requires all the necessary information and various viewport. BIM modeling of the bathroom was conducted in accordance with the requirements of the certification for barrier-free living environment. The results suggested that there is a need for a removal of thresholds, larger doors, better selection of finishing materials, sufficient room for a wheelchair, larger space next to the toilet, and the availability of an emergency bell and grab bars. Such information supports the potentials of BIM modeling, and it is expected that an automated certification system would be established in the foreseeable future.

A Study on the Passenger Circulation system of the Airport Passenger Terminal (공항 여객터미널 여객동선체계에 관한 연구)

  • Park, Chung-Keun
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.260-268
    • /
    • 2010
  • At a passenger terminal which is a core facility of a large-scale airport, users are not easy to recognize its space and to approach each facility by composition of large-scale space not recognized at a glance and arrangement of complicated functional space. Such a passenger terminal should be designed by putting a focus on functionality, safety and convenience since diverse passengers use it. At a passenger terminal, a lot of passengers' circulation followed by diverse purpose appear. Therefore, it needs a lot of functional space and space to satisfy passengers' demands. When circulation is planed, it should be designed by a systematic standard. The study was carried out on the basis of international airports, considering features and functions of airport circulation system. In kind of circulation in passenger terminal of an airport, there are user's circulation (passenger's circulation, employee's circulation and service circulation) and baggage circulation. The study examined passenger's circulation which was a major circulation of passenger terminal out of user's circulation. The study examined elements which had an effect on circulation system at a large-scale airport passenger terminal and basic data for an efficient circulation system standard of passenger terminal through case analysis of passenger terminal circulation systems at international airports.

Experimental Study on Design Verification of New Concept for Integral Reactor Safety System (일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구)

  • Chung, Moon-Ki;Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Park, Choon-Kyung;Lee, Sung-Jae;Song, Chul-Hwa
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF

Design and Lay Out of Propulsion Test Facilities for KSLV-II (한국형발사체(KSLV-II) 추진기관 시험설비 배치 및 설계)

  • Han, Yeoung-Min;Cho, Nam-Kyung;Chung, Young-Gahp;Kim, Seung-Han;Yu, Byung-Il;Lee, Kwang-Jin;Kim, Jin-Sun;Kim, Ji-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.56-61
    • /
    • 2011
  • The deign and lay-out of a combustion chamber test facility(CTF), a turbopump real propellant test facility(TPTF), a rocket engine test facility for 3rd stage engine(SReTF), a rocket engine ground/high altitude test facility(ReTF, HAReTF) and a propulsion system test complex(PSTC) for KSLV-II is briefly described. The development/qualification tests of engine component, 3rd stage engine system and 75ton-class liquid rocket engine system will be performed in CTF, TPTF, SReTF, ReTF and HAReTF and the development test of 1st/2nd/3rd propulsion systems for KSLV-II will be performed in PSTC. These propulsion test facilities will be built in NARO space center considering construction schedule, cost, safety distance and utility factor of propulsion test facilities.

  • PDF

Research on the Design Trends and Spatial Components of Han-Ok Public Daycare Center - Focused on Drawings of Neo-Korean Style Public Daycare Center on Heung-cheon/Su-rak/Geumgwa, Korea - (신한옥 공공 어린이집에 나타난 건축계획적 특성에 관한 조사연구 - 서울 흥천, 서울 수락, 순창 금과 어린이집의 설계도서를 중심으로 -)

  • Kim, Young-Hoon;Peck, Yoo-Jung
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.47-54
    • /
    • 2016
  • Purpose: Grafting new hanok-style application technology on child daycare facility among public buildings can be an alternative that provides infant facility, which is placed at the center of social attention and interest, with pleasant nursing environment. Besides, it is expected to have a great impact on infants' and young children's emotion by helping them recognize traditional culture at early stage and furthermore can be used for villagers to experience differentiated traditional culture. Method: To investigate the recent construction of HeungCheon/SuRak/GeumGwa's Hanok child daycare facility recognizing for architectural planning characteristics in common tendency Hanok that presents a physical improvement plan for preparing the continued competitiveness. Also attention to the creative expression of the traditional spaces about the natural environment are implemented in Nurseries and we propose the possibilities that can be realized in the future Hanok child daycare facility. Result: The combination of modern materials and modern construction technology of New-hanok method with improved ability has improved the shortcomings of traditional architecture and increase the ease and safety of traditional architecture succeed the suggest direction of improvement modern society. Therefore, Hanok child daycare facility is preparing adequate capability to solve regional polarization and social care issues.

Design consideration and explosion safety of underground ammunition storage facilities (지하탄약고의 설계요소 및 폭발안전 연구)

  • Kim, Oon-Young;Lee, Myung-Jae;Kim, Min-Seok;Kim, Joon-Youp;Joo, Hyo-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.55-70
    • /
    • 2003
  • Ammunition magazine, which is installed on the ground, has difficulty in protecting from the external attack, and accidental explosion should cause great damage to the life and property. For these reasons, it is needed to develop underground magazine that it has the advantages of safety, security and maintenance. This paper introduce the design case for blasting facilities, which should resist blasting pressure, as well as layout of underground magazine, which takes a safety for explosion and a working space of loading/unloading machine into consideration. On the layout, in case of ${\bigcirc}{\bigcirc}$ underground magazine, put three storage chambers in position almost parallel with principle stress direction, where less effected on discontinuity and hard rock area. Also, secured safe distance according to safety criteria of the Defense Ministry, and verified suitable layout by trace simulation for loading/unloading machine on working stage. Blasting design was performed on evaluation of maximum blast pressure between donar and acceptor chambers, and design condition for blast door, valve, etc. Diminution facilities against explosion, such as thrust block or debris trap, determined its size after plan in accordance with blasting criteria and calculation by structural analysis.

  • PDF

Estimation of Safety in Railway Tunnel by Using Quantitative Risk Assessment (QRA를 이용한 철도터널 방재 안전성 평가)

  • Kim, Do-Sik;Kim, Do-Hyung;Kim, Woo-Sung;Lee, Du-Hwa;Lee, Ho-Seok
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.357-367
    • /
    • 2006
  • Recently, as the construction of new railway and the relocation of existing line increase, tunnel structures grow longer. The railway fire accidents in long tunnel bring large damages of human life and disaster. The interest of safety in long tunnel have a growing and the safety standard of long tunnel is tightening. For that reason, at the planning of long tunnel, the optimum design of safety facility in long tunnel for minimizing the risks and satisfying the safety standard is needed. For the reasonable design of long railway tunnel considering high safety, qualitative estimation for tunnel safety is required. In this study, QRA (Quantitative Risk Assessment) technique is applied to design of long railway tunnel for assuring the safety function and estimating the risk of safety. The case study for safety design in long railway tunnel is tarried out to verifying the QRA technique for two railway tunnels. Thus, the inclined and vertical shaft for escape way and safety facilities in long tunnel are planned, and the risks of tunnel safety for each case are estimated quantitatively.

Occupational Health and Safety Management and Turnover Intention in the Ghanaian Mining Sector

  • Amponsah-Tawiah, Kwesi;Ntow, Michael Akomeah Ofori;Mensah, Justice
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 2016
  • Background: The mining industry is considered as one of the most dangerous and hazardous industries and the need for effective and efficient occupational health and safety management is critical to safeguard workers and the industry. Despite the dangers and hazards present in the mining industry, only few studies have focused on how occupational health and safety and turnover intentions in the mines. Method: The study suing a cross-sectional survey design collected quantitative data from the 255 mine workers that were conveniently sampled from the Ghanaian mining industry. The data collection tools were standardized questionnaires that measured occupational health and safety management and turnover intentions. These scales were also pretested before their usage in actual data collection. Results: The correlation coefficient showed that a negative relationship existed between dimensions of occupational health and safety management and turnover intention; safety leadership (r = -0.33, p < 0.01); supervision (r = -0.26, p < 0.01); safety facilities and equipment (r = -0.32, p < 0.01); safety procedure (r = -0.27, p < 0.01). Among these dimensions, safety leadership and safety facility were significant predictors of turnover intention, (${\beta}=-0.28$, p < 0.01) and (${\beta}=-0.24$, p < 0.01) respectively. The study also found that turnover intention of employees is heavily influenced by the commitment of safety leadership in ensuring the effective formulation of policies and supervision of occupational health and safety at the workplace. Conclusion: The present study demonstrates that safety leadership is crucial in the administration of occupational health and safety and reducing turnover intention in organizations.

Analysis of User Requirements for Development of Vessel Traffic Services Cloud System (선박교통관제 클라우드 시스템 개발에 따른 사용자 요구사항 분석)

  • Lee, Li-Na;Kim, Joo-Sung;Lee, Hong-Hoon;Lee, Jin-Suk;Namgung, Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.314-323
    • /
    • 2022
  • Vessel Traffic Services (VTS) operators perform traffic management tasks using VTS systems and sensor equipment designated as VTS facilities to promote the safety and efficiency of vessel traffic. The necessary VTS information for effective operations could be obtained through the additional access of various information channels other than the designated VTS facility. To unify these various information access windows, the development of the VTS cloud system is in progress. In this study, the operational information analysis for VTS was performed through VTS tasks-facility linkage analysis to identify the user required information according to the introduction of the VTS cloud system. The VTS task analysis was performed through research of the international and domestic literature, and expert interviews. The necessary information were identified and linked according to the VTS facilities. As a result of the analysis, 37 categories of necessary information were identified for internal and external information windows, and 8 information windows were selected other than the present VTS equipment. The identified user requirements would be applied to the structure design of the VTS cloud system. In the future, it is necessary to update user requirements through scenario-based user operation analysis and to conduct additional research on the system interface design.

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.