• Title/Summary/Keyword: Facility safety design

Search Result 508, Processing Time 0.029 seconds

The Characteristics of Mixed-use School and Park with Parking Facility in Urban Residential Area (도시 주거지 학교와 공원의 주차장 입체화 사례의 형태와 이용 특성 분석)

  • Kim, Yoon-Sun;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.153-158
    • /
    • 2011
  • According to the change of life environment and economic growth, the more city has highly developed, the more concentrated urban function. That is, city is required for adding infra structure. But, both of limited land resources and financial problems made it impossible to add infra structure. So, the necessity of multi-dimensional planning of urban infra structure was recognized. Especially, In Urban residential area, in order to secure parking area, It is on the increase that mixed-use of the playground of school in the high density area and the empty space of park. School and park is closely connected with town community, playing a central role on town life. For this reason, they are highly demanded for providing space in the urban residential area and also expected to be effective. However, people using park and school are almost young students and the elderly, it needs to consider not only the parking convenience also the safety of users in design process. In this study, we analysed the physical characteristics and the utilization of mixed-use of school and park. and then evaluated the case in the point of convenience and safety. For this, first we selected the case among the sites constructed in seoul, and divided 2type of 'slope type' and 'flatland type'. The meaning of this study is to suggest elementary standards for design in the point of multi-dimensional land use planning.

  • PDF

A Conceptual Design on Performance Test Facility of Disposal Cover for the Near Surface Disposal of Low and Intermediate Level Radioactive Waste (중.저준위 방사성폐기물 천층처분을 위한 처분덮개의 성능실증 시험시설 개념설계)

  • 이찬구;박세문;김창락;염유선;이은용
    • The Journal of Engineering Geology
    • /
    • v.11 no.3
    • /
    • pp.245-254
    • /
    • 2001
  • The experimental study on disposal cover through the performance test facility offers reliability in the safety of near surface disposal of low and intermediate level radioactive waste. To ensure the long-term safety of the repository, the impermeability, integrity, resistance to degradation and ease of maintenance might be considered as the basic performance requirement of the disposal cover. considering the difficulties to meet these performance requirement by using single layer, the disposal cover design which is composed of top layer, middle drainage layer and bottom low permeability layer is schemed for the test facility. The water balance of the cover was evaluated by using HELP code. For the long-term monitoring of the soil moisture content and matric potential, TDR probes and tensiometers will be installed in 6 test cells. Each test cell is dimensioned 3$\times$3$\times$3.3m.

  • PDF

Corrosion Evaluation for Advanced Fuel Cycle Facilities (선진 핵연료주기 시설(AFC)의 부식건전성 조사, 분석)

  • Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.213-217
    • /
    • 2012
  • The amount of spent fuel from nuclear power plants has been increasing. An effective management plan of the spent fuel becomes a critical issue, because the storage capacity of each plant will reach its storage limit in a few years. The volume of high toxic spent fuel can be reduced through a fuel processing. Advanced Fuel Cycle (AFC) system is considered to be one of the options to reduce the toxicity and volume of the spent fuel. It is necessary to set up a test facility to demonstrate the feasibility of the process at the engineering scale. The objective of the work is a development of the safety evaluation technology for the AFC system. The evaluation technology of the AFC structural integrity and processes were surveyed and reviewed. Key evaluation parameters for the main processes such as electrolytic reduction, electrorefining, and electrowinning were obtained. The survey results may be used for the establishment of the AFC regulatory licensing procedure. The establishment of the licensing criteria minimizes the trials and errors of the AFC facility design. Issues taken from the survey on the regulatory procedure and design safety features for the AFC facility provide a chance to resolve potential issues in advance.

A framework for 4D analysis of construction safety using a Site Information Model

  • Jongwoo CHO;Jiyu SHIN;Tae Wan KIM
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.516-523
    • /
    • 2024
  • This study introduces a comprehensive framework for 4D safety analysis in construction site layout planning (CSLP), using a Site Information Model (SIM) environment to enhance spatial hazard identification and effectively integrate it with activity-based safety management. The framework, grounded in a continuous-space layout approach, accurately positions objects to mirror temporary facilities' actual boundaries, incorporating spatial relationships and inherent safety hazards. It also features rasterization to translate layouts into a grid system. Central to this framework are three modules for spatial hazard identification: Visibility Analysis, Spatial Hazard Mapping, and Travel Path Analysis, designed to identify less visible spaces, assess spatial hazards, and simulate optimal travel paths considering safety aspects. By applying this framework to case studies of a residential complex and a commercial office project, the research demonstrates its practical utility in improving visibility and spatial hazard assessment, despite the inherently complex dynamics of construction sites. The study acknowledges challenges, such as the reliance on safety managers' experiential knowledge for setting hazard parameters and the need for further development in integrating these insights with activity-based safety management. It underscores the framework's significant potential to advance construction safety management by offering a method to preemptively recognize and mitigate spatial hazards. The approach promises not only to contribute to accident prevention but also to enhance overall project performance by incorporating spatial and temporal dimensions of safety into CSLP. This research marks a significant step toward a more holistic and integrated approach to construction safety, highlighting the importance of continuous improvement and adaptation in safety practices.

A Case Study on Operation of Off-Gas Treatment System of Radioactive Waste Vitrification Facility (방사성폐기물 유리화설비의 배기가스 처리계통 운영 사례 연구)

  • Lee, Hye Hyun;Park, Kyu Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.5
    • /
    • pp.249-254
    • /
    • 2016
  • In this study, we investigated the main characteristics of off-gas generated from melting process and off-gas treatment system operation example to provide some primary data for commercial vitrification facility design. The purpose of vitrification facility operation is to treat hazardous materials in the radioactive wastes and harmful off-gas containing a variety of chemical species generated in the glass melting process. Constructing and operating vitrification facility essentially need to be licensed through safety analysis; it is very important to treat radionuclide and hazardous materials below the legal environment emissions regulation level. We must accurately understand the characteristics of off-gas and apply an appropriate off-gas treatment process accordingly. Thus, to design the appropriate off-gas treatment there must be a wide range of elements taken into account such as characteristics of waste and melter, regulation guidance of off-gas, characteristics of generated off-gas and off-gas treatment system performance assessment.

Preliminary Radiation Exposure Dose Evaluation for Workers of the Landfill Disposal Facility Considering the Radiological Characteristics of Very Low Level Concrete and Metal Decommissioning Wastes (극저준위 콘크리트, 금속 해체방폐물의 방사선적 특성을 고려한 매립형 처분시설 방사선작업자 예비 피폭선량 평가)

  • Ho-Seog Dho;Ye-Seul Cho;Hyun-Goo Kang;Jae-Chul Ha
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.509-518
    • /
    • 2023
  • The Kori Unit 1 nuclear power plant, which is planned to be dismantled after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during the dismantling process. For the disposal of Very-low-level waste, which is expected to account for the largest amount of generation, the Korea Radioactive waste Agency (KORAD) is in the process of detailed design to build a 3-phase landfill disposal facility in Gyeongju. In addition, a large container is being developed to efficiently dispose of metal and concrete waste, which are mainly generated as Very low-level waste of decommissioning. In this study, based on the design characteristics of the 3-phase landfill disposal facility and the large container under development, radiation exposure dose evaluation was performed considering the normal and accident scenarios of radiation workers during operation. The direct exposure dose evaluation of workers during normal operation was performed using the MCNP computer program, and the internal and external exposure dose evaluation due to damage to the decommissioning waste package during a drop accident was performed based on the evaluation method of ICRP. For the assumed scenario, the exposure dose of worker was calculated to determine whether the exposure dose standards in the domestic nuclear safety act were satisfied. As a result of the evaluation, it was confirmed that the result was quite low, and the result that satisfied the standard limit was confirmed, and the radiational disposal suitability for the 3-phase landfill disposal facility of the large container for dismantled radioactive waste, which is currently under development, was confirmed.

Evaluation of Left-Turn Passages for Bicycle Traffic in Mixed Traffic Stream at Signalized Intersections (혼합교통류 신호교차로에서 자전거교통 좌회전 통행방식 평가연구)

  • Joo, Shin-Hye;Oh, Cheol;Lee, Sang-Soo
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.145-155
    • /
    • 2012
  • PURPOSES: This study proposes a novel method based on microscopic simulation models to evaluate bicycle passing ways in mixed traffic flow conditions at signalized intersections. METHODS: Both operational efficiency and safety are taken into consideration in the evaluation. A widely used performance measure, delay, is used for evaluating the operational efficiency. Regarding the safety evaluation, surrogate safety measures (SSM) to represent traffic conflicts and the level of crash severity, DeltaS and Max.DeltaV, are applied in the proposed method. RESULTS: Extensive simulations and statistical tests show that an integrated bike-box way is identified as the best in terms of operational efficiency and safety. CONCLUSIONS: The proposed method and outcomes of this study will be valuable for bicycle traffic operations and facility design.

Effects of Students' Perceived Safety of Public Outdoor Environment on Academic Achievement at University Campus

  • Kim, Wonpil
    • Architectural research
    • /
    • v.17 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • The physical environment can dramatically affect students' feeling and their behavior, educational attainment, and the way in which we do school activities. Unlimited access to campus areas without appropriate securities have reported an increase of crime in school area and safety issues has encouraged school facility planners to install securities devices at every corner of buildings. However, it is still questionable whether this approach is enough to protect students and staffs from the victimization of crime, including thefts, burglaries and sexual offences. There has been continued doubt about the safety of educational facilities where individual college students are studying and enjoying extra-curricular activities. Therefore, the purpose of this study is intended to investigate the effects of perception of safety by students on the level of academic performance at public outdoor environment of university campus. An extensive literature noted that the central element of modern school design principle mainly holds the theory of crime prevention through environmental design (CPTED) and the concept of defensible space. The second generation of CPTED also focused on social soft issues as well as situational factors, which extends beyond mere physical design to include social factors. The correlation analysis found that the effect of sense of safety does appear to be statistically significant on the facilitation of academic achievement. However, the analysis of Chi-square concluded that the perception of safety was not related to demographic and socio-economic profiles of the group except for gender. Further, stepwise multiple regression analysis revealed that the most prime predictor for academic achievement were 'safe public outdoor space/paths' at university campus environment, implying careful design of public open space and sidewalks based on the guideline of CPTED. The study also demonstrated that as the level of positive perception of safety rose, the overall academic achievement also responded to the specified rate (${\beta}=.99$). Finally, the findings reinforce an evidence that high-quality school environments are a positive factor in student academic performance.

INTEGRAL BEHAVIOR OF THE ATLAS FACILITY FOR A 3-INCH SMALL BREAK LOSS OF COOLANT ACCIDENT

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Euh, Dong-Jin;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.199-212
    • /
    • 2008
  • A small-break loss of coolant accident (SB-LOCA) test with a break size equivalent to a 3-inch cold leg break of the APR1400 was carried out as the first transient integral effect test using the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation). This was the first integral effect test to investigate the integral performance of the test facility and to verify its simulation capability for one of the design-basis accidents. Reasonably good thermal hydraulic data was obtained so that an integral performance of the fluid sub-systems was identified and control performance of the ATLAS was confirmed under real thermal hydraulic conditions. Based on the measured data, a post-test calculation was carried out using the best-estimate thermal hydraulic safety analysis code, MARS 3.1, and the similarity between the expected and actual data was investigated. On the whole, the post-test calculation reasonably predicts the major thermal hydraulic parameters measured during the SB-LOCA test. The obtained data will be used to enhance the simulation capability of the ATLAS and to improve an input model of the ATLAS for simulation of other target scenarios.

Estimation of the Isolator Displacement for the Performance Based Design of Nuclear Power Plants (원전 적용을 위한 면진장치의 성능기반 설계 변위 추정)

  • Kim, Jung Han;Choi, In-Kil;Kim, Min Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.291-299
    • /
    • 2014
  • There has been an increasing demand for introducing a base isolation system to secure the seismic safety of a nuclear power plant. However, the design criteria and the safety assessment methodology of a base isolated nuclear facility are still being developed. A performance based design concept for the base isolation system needs to be added to the general seismic design procedures. For the base isolation system, the displacement responses of isolators excited by the extended design basis earthquake are important as well as the design displacement. The possible displacement response by the extended design basis earthquake should be limited less than the failure displacement of the isolator. The failure of isolators were investigated by an experimental test to define the ultimate strain level of rubber bearings. The uncertainty analysis, considering the variations of the mechanical properties of isolators and input ground motions, was performed to estimate the probabilistic distribution of the isolator displacement. The relationship of the displacement response by each ground motion level was compared in view of a period elongation and a reduction of damping. Finally, several examples of isolator parameters are calculated and the considerations for an acceptable isolation design is discussed.