• Title/Summary/Keyword: Facility maintenance

Search Result 872, Processing Time 0.03 seconds

Implications of a Case Analysis of a Public Park Project at a Former Military Facility Site (군사시설 이전부지 공원화 사례분석을 통한 시사점 도출)

  • Park, Joon-Young;Lee, Eun-Yeob;Song, Sun-Young;Yeob, Jung-Sik
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.225-234
    • /
    • 2014
  • Because of their nature as public facilities, demands that former military facilities be utilized for the public welfare are increasing, thereby leading to an increase in cases in which these military facilities are reestablished as parks. Cases in which former military bases were reestablished as public parks were analyzed; as a result, several implications were derived. First, the objectives of public park projects should be examined from the perspective of the concept of urban regeneration and regional revitalization. Moreover, it is necessary that profits are yielded and that regional identity and history are reproduced through reusing existing facilities as much as possible rather than entirely remodeling former military sites. As parks become larger in size, bases should be reorganized into complexes rather than single facilities or programs. It is also necessary that parks be established in stages considering the enormous expenses required for building public parks. Consequently, because the special characteristics of military facilities can lead to insufficient on-site investigation in the process of establishing parks, thereby incurring a vast amount of costs for design adjustment and contamination disposal, this should be considered in advance. A method of delegating the development rights to partial sites to private businesses and supplementing the costs of park establishment and maintenance with development benefits should be examined. In addition, given that there are various interests and stakes in former military bases, a method of operating a public-private cooperative decision-making organization during project execution should be considered. Finally, policies related to urban parks need to be improved in order to raise funds, expand profitable businesses, facilitate social services and sponsorship, and encourage the participation of trusts and non-profit organizations in park operation and management.

The Characteristics of Farm Household in Suburban Areas Classified by the Farming Types and Changes of Facility Farm Household's Management Size - A Case Study of Munsanli, Taegu - (대도시근교 농촌지역의 농가특성과 시설농가의 경영규모 변화 - 대구광역시 문산리를 사례로 -)

  • Park, Yang-Choon;Woo, Jong-Hyeon
    • Journal of the Korean association of regional geographers
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 2001
  • Summarized results of this study that examined the characteristics of farm household in suburban areas classified by the fanning types are as follows. When it was looked into with the side of farm household and his family, the type of the farm household in suburban areas are related to the quality of fanning labor rather than the quantity of it. Regardless of the type of the farm household, it depends upon the family labor (usually men and wives). And the age of farm manager is an important part in the quality of fanning labor. The size of the farm household is related to the individual fanning labor. The size of self-sufficient crops(mainly rice) farm household will be small as the farmer gets to be old. But the size of commercial crops farm household has less tendency to change in terms with the age of farm manager. The fanning commercialism takes an important part in the maintenance and development of suburban agricultural areas. But, in fact, there is a shortage of farming labor. So the physical condition of farmland is the most important part in agricultural durability. After this study, we can conclude that we won't have enough chance to solve the problem of family member separation and shortage of fanning labor even though it is in the suburban area or in the profitable farm until we give them more enough chance to get a job(except fanning) and the better education infrastructure. To make matters worse, the aggravation of farm house-hold's economy due to unstable price of farming products' threatens the agricultural durability. Consequently, in order to get a development of agriculture and rural community, a qualitative change with improvement of agricultural conditions and of products distribution system is needed.

  • PDF

Study on the Institutional Control Period Through the Post-drilling Scenario Of Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste (중·저준위 방사성폐기물 천층처분시설에서 시추 후 거주시나리오 평가를 통한 폐쇄 후 제도적 관리기간 연구)

  • Hong, Sung-Wook;Park, Jin-Baek;Yoon, Jung-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The public's access to the disposal facilities should be restricted during the institutional control period. Even after the institutional control period, disposal facilities should be designed to protect radiologically against inadvertent human intruders. This study is to assess the effective dose equivalent to the inadvertent intruder after the institutional control period thorough the GENII. The disposal unit was allocated with different kind of radioactive waste and the effects of the radiation dose to inadvertent intruder were evaluated in accordance with the institutional control period. As a result, even though there is no institutional control period, all were satisfied with the regulatory guide, except for the disposal unit with only spent filter. However, the disposal unit with only spent filter was satisfied with the regulatory guide after the institutional control period of 300 years. But the disposal unit with spent filter mixed with dry active waste could shorten the institutional control period. So the institutional control period can be reduced through the mixing the other waste with spent filter in disposal unit. Therefore, establishing an appropriate plan for the disposal unit with spent filter and other radioactive waste will be effective for radiological safety and reduction of the institutional control period, rather than increasing the institutional control period and spending costs for the maintenance and conservation for the disposal unit with only spent filter.

A Study on the Development and Utilization of Indoor Spatial Information Visualization Tool Using the Open BIM based IFC Model (개방형 BIM 기반 IFC 모델을 이용한 실내공간정보 시각화 도구개발 및 활용방안 연구)

  • Ryu, Jung Rim;Mun, Son Ki;Choo, Seung Yeon
    • Spatial Information Research
    • /
    • v.23 no.5
    • /
    • pp.41-52
    • /
    • 2015
  • MOLIT (Minister of Land, Infrastructure and Transport) authorized Indoor Spatial Information as Basic spatial information in 2013. It became a legal evidence for constructing and managing Indoor Spatial Information. Although it has a little advantage to utilize as service level that Indoor Spatial Information by laser scan or measurement, it has a lot of problems such as consuming many resources, requiring additional progresses for inputting Object Information. In conclusion, it is inefficient to utilize for the maintenance and domestic AEC/FM field. The purposes of this study is to output Indoor Spatial Information by operating IFC model which based on open BIM and to improve availability of Indoor Spatial Information with data visualization. The open-sources of IFC Exporter, a inner program of Revit (Autodesk Inc), is used to output Indoor Spatial Information. Directs 3D Library is also operated to visualize Indoor Spatial Information. It is possible to inter-operate between XML format and the objects of Indoor Spatial Information. It can be utilized in various field as well. For example COBie linkage in facility management, construction of geo-database using air-photogrammetry of UAV (Unmaned Areal Vehicle), the simulation of large-scale military operations and the simulation of large-scale evacuation. The method that is purposed in this study has outstanding advantages such as conformance with national spatial information policy, high level of interoperability as indoor spatial information objects based on IFC, convenience of editing information, light level of data and simplifying progress of producing information.

Study about Component Identification Method Based On RUP (RUP 기반의 컴포넌트 식별 방법에 관한 연구)

  • Choe, Mi-Suk;Yun, Yong-Ik;Park, Jae-Nyeon
    • The KIPS Transactions:PartD
    • /
    • v.9D no.1
    • /
    • pp.91-102
    • /
    • 2002
  • We need a component-based system to reflect software changes in user's requirements, to implement a system at a rapid speed as well as to efficiently manage the system in a maintenance phase and to easily change software. Moreover, the component-based system has a merit in development cost. However, existing component development methodology for implement of component-based system is inefficient in object identification for component identification. Moreover, the existing component development methodology also fails to provide any method to identify system component. It merely provides procedures and methods to identify business component focused on a whole system domain. In addition, it has another problem that it considerably relies on developer's experiences and intuitions for component identification. Therefore, according to this paper, RUP (Rational Unified Process) is applied from a requirement analysis phase to an object identification phase in order to improve the inefficiency of object identification. In addition, this paper procedures and methods for system component identification, and identifies business components based on the identified system component, rather than on the whole system domain. This paper also provides and applies cohesion metric and coupling metric so as to overcome the problem that component identification depends on developer's intuitions and experiences. Accordingly, the component identification method proposed in this paper, may identify components more effectively based on facility of object identification, functional reusability of components, traceability, and independence of components.

Analysis of Energy Usage Quantity According to Physical Characteristics of Elementary, Middle, and High School of Each Regions (지역별 초·중등학교의 물리적 특성에 따른 에너지 사용량 분석)

  • Ryu, Han-Guk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • School facilities are one of the important educational requirements, and it is necessary to maintain safe and sustainable for the ongoing educational environment. For this reason, educational government department have an effort to produce school facilities that have become safe, comfort, convenient and high-quality. There are many methods to improve existing buildings and build new schools by energy efficient technology. Even though educational environment of school facilities are improved by the efforts, the energy consumption has a huge increase. Energy is a major budget item for schools. The accurate estimation of energy cost is critical for effective budgeting and financing for the school facility maintenance. Accurate energy cost estimation also allow for a anticipatable LCC (Life Cycle Cost) of new school facilities. In this study, in order to produce a basic information about the present energy usage status in domestic school facilities, energy usage quantity is regionally analysed according to physical characteristics of elementary, middle, and high school facilities. Those results will give a chance to see deeply the pros and cons of energy usage each regional school facilities.

Filter Media Specifications for Low Impact Development: A Review of Current Guidelines and Applications (LID 시설 여재에 관한 기술지침 및 적용에 관한 고찰)

  • Guerra, Heidi B.;Kim, Lee-Hyung;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.321-333
    • /
    • 2019
  • A primary aspect of low impact development (LID) design that affects performance efficiency, maintenance frequency, and lifespan of the facility is the type of filter media as well as the arrangement or media profile. Several LID guidelines providing media specifications are currently available and numerous studies have been published presenting the effectiveness of these systems. While some results are similar and consistent, some of them still varies and only a few focuses on the effect of filter media type and arrangement on system performance. This creates a certain level of uncertainty when it comes to filter media selection and design. In this review, a synthesis of filter media specifications from several LID design guidelines are presented and relevant results from different laboratory and field studies are highlighted. The LID systems are first classified as infiltration or non-infiltration structures, and vegetated or non-vegetated structures. Typical profiles of the media according to classification are shown including the different layers, materials, and depth. In addition, results from previous studies regarding the effect of filter media characteristics on hydraulic and hydrologic functions as well as pollutant removal are compared. Other considerations such as organic media leaching, clogging, media washing, and handling during construction were also briefly discussed. This review aims to provide a general guideline that can contribute to proper media selection and design for structural LIDs. In addition, it also identifies opportunities for future research.

Remodeling Process Model Applying Service Life and Functionality Evaluation for Military Facilities (내용연수와 기능성 평가를 활용한 군 시설물 리모델링 대상 선정 프로세스 모델)

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Kim, Jaegon;Moon, Hyo-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.41-52
    • /
    • 2015
  • The number of military facilities has been rapidly increased due to growing requirement of modernization and military welfare. However, adequate maintenance has not implemented to these facilities. As a result, they are deteriorated quickly and require performance enhancement treatments. There are two ways of performance enhancement, reconstruction and remodeling. Despite the research result that remodeling within the standard remodeling range is more economical, remodeling of military facilities is not considered equivalent to reconstruction as an option of performance improvement. Therefore, derived from the relationship between performance change during life cycle of building and range of remodeling needs, this study tries to propose Remodeling Process Model(RPM) which uses a method to choose remodeling in a Specific Point of Time(SPT) when remodeling is considered more economical than reconstruction. In addition, this study suggests practical service life and functionality evaluation standard together which require to realize the RPM. This RPM make it possible to avoid the cases that facilities which do not have any problem on structural reliability but have low level of functionality miss appropriate remodeling timing and inevitably choose reconstruction as a performance improvement option. It also present the possibility of simple reconstruction / remodeling decision-making for facility managers who administrate building having various type, compilation and elapsed time. Consequently, this process model focusing on remodeling more may contribute to reduce resource waste caused by reconstruction.

A Study on the Analysis of Current Situation of Safety Inspections cost in Apartment houses (공동주택 안전점검대가 현황분석에 관한 연구)

  • Go, Seong-Seok;Song, Do-Heom;Yun, Yeong-Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.62-70
    • /
    • 2014
  • An apartment house, a private facility, is a house built for many persons to live independently in a building. An apartment house is a building where life damage can happen most in case of a safety accident due to insufficient inspections. However, formal inspections are being realized due to awareness shortage of managing bodies about safety inspection and low-price order-receiving of diagnosing enterprises via the lowest bidding method. This is because it is judged that remarkable costs are inputted in repairs and reinforcement such as maintenance of a structure and that there is a large possibility of human damage in case of a safety accident in a structure. So, this paper aims to derive the points to improve in the current criterion to execute an efficient detailed inspection. As its method, the design price and execution price situation of 66 buildings inspected in detail for recent 3 years for the class 2 facilities in Gwangju Metropolitan City and Jeonranam-do are examined and analyzed. The state2 object buildings to inspect are selected through this. And this paper aims to present the points to improve through the analysis of current problems by evaluating the detailed inspection report and the detailed inspection execution price calculation criterion for the selected 10 apartment houses.

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.