• 제목/요약/키워드: Facility Operation

검색결과 1,486건 처리시간 0.029초

Applications of Agent-Based Modeling (ABM) in Enhancing Facility Operation and Management

  • Khodabandelu, Ali;Park, JeeWoong
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.393-400
    • /
    • 2022
  • Agent-based modeling (ABM), as a relatively new simulation technique, has recently gained in popularity in the civil engineering domain due to its uniquely advantageous features. Among many civil engineering applications, ABM has been applied to facility operation and management, such as energy consumption management, as well as the enhancement of maintenance and repair processes. The former studies used ABM to manage energy consumption through simulating human energy-related behaviors and their interactions with facilities, as well as electrical, heating, and cooling systems and appliances, while the latter used ABM to enhance maintenance process through facilitating coordination, negotiation, and decision making between facility managers, service providers, and repair workers. The present study aims to provide a short qualitative review on the most recent applications of ABM in the above-mentioned areas. Based on the review and follow-up analysis, the study identifies the advantages, disadvantages, and limitations of ABM applications to facility operation and management, and offers several potential future research topics in the hope of filling the existing literature gaps.

  • PDF

단일 범용설비 운영을 위한 (r, Q) 정책 ((r, Q) Policy for Operation of a Multipurpose Facility)

  • 오근태
    • 한국경영과학회지
    • /
    • 제17권3호
    • /
    • pp.27-46
    • /
    • 1992
  • This paper considers an (r, Q) policy for operation of a multipurpose facility. It is assumed that whenever the inventory level falls below r, the model starts to produce the fixed amount of Q. The facility can be utilized for extra production during idle periods, that is, when the inventory level is still greater than r right after a main production operation is terminated or an extra production operation is finished. But, whenever the facility is in operation for an extra production, the operation can not be terminated for the main production even though the inventory level falls below r. In the model, the demand for the product is assumed to arrive according to a compound Poisson process and the processing time required to produce a product is assumed to follow an arbitary distribution. Similarly, the orders for the extra production is assumed to accur in a Poisson process are the extra production processing time is assumed to follow an arbitrary distribution. It is further assumed that unsatisfied demands are backordered and the expected comulative amount of demands is less than that of production during each production period. Under a cost structure which includes a setup/ production cost, a linear holding cost, a linear backorder cost, a linear extra production lost sale cost, and a linear extra production profit, an expression for the expected cost per unit time for a given (r, Q) policy is obtained, and using a convex property of the cost function, a procedure to find the optimal (r, Q) policy is presented.

  • PDF

초등학교 복합화시설 모니터링 평가연구 - 서울시 초등학교를 중심으로 - (A Study on the Monitoring Evaluation of Elementary School Complex Facilities - Focusing on Elementary Schools in Seoul -)

  • 목정훈
    • 교육시설
    • /
    • 제16권5호
    • /
    • pp.3-10
    • /
    • 2009
  • The purpose of this study is to provide an remodification method for elementary school complex facilities in Seoul Metropolitan city. This study analyzes the questionnaire survey for 568 entire elementary schools and the questionnaire survey for school facility complex project operated 44 elementary schools. Then the result of this study was deduced from the comparison between the 568 entire survey data and 44 survey data in terms of the cognition of school facility complex project, the required type of facility and the problems of complex facility maintenance and operation. Four major findings were revealed as the result of research. First, there is a very high agreement with the school facility complex projects. Second, it was need that the process of planning and design was remodified to enhance participation of parents of students and local residents for selecting an appropriate complex facility. Third, education environment and student safety should be protected from any other school facility complex environments. Fourth, an agreement and regulation is needed for more effective maintenance and operation of school complex facilities.

액체로켓엔진 연소기 지상연소시험설비 운영관리 기술 (Operation Techniques of Liquid Rocket Engine Combustor Ground Firing Test Facility)

  • 강동혁;임병직;문일윤;서성현;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.157-162
    • /
    • 2006
  • 한국 최초의 액체로켓인 과학로켓 3호(KSR-III) 엔진 개발을 위해 로켓엔진 연소기 지상연소시험설비가 2001년도에 한국항공우주연구원 내에 준공되었다. 본 시험설비는 준공 후 2006년 9월 현재까지 약 170회에 이르는 액체로켓엔진 연소기 시험을 수행하였으며, 그 과정에서 설비 능력 면에서 상당한 개량이 이루어졌다. 본 논문에서는 한국항공우주연구원 액체로켓엔진 연소기 지상연소시험설비의 개요와 수행시험, 그리고 그 동안 축적해 온 설비 운영기술에 대하여 소개한다.

  • PDF

Neutronic and thermohydraulic blanket analysis for hybrid fusion-fission reactor during operation

  • Sergey V. Bedenko ;Igor O. Lutsik;Vadim V. Prikhodko ;Anton A. Matyushin ;Sergey D. Polozkov ;Vladimir M. Shmakov ;Dmitry G. Modestov ;Hector Rene Vega-Carrillo
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2678-2686
    • /
    • 2023
  • This work demonstrates the results of full-scale numerical experiments of a hybrid thorium-containing fuel plant operating in a state close to critical due to a controlled source of D-T neutrons. The proposed facility represented a level of generated power (~10-100 MWt) in a small pilot. In this work, the simulation of the D-T neutron plasma source operation in conjunction with the facility blanket was performed. The fission of fuel nuclei and the formation of spatial-energy release were studied in this simulation, in pulsed and stationary modes of the facility operation. The optimization results of neutronic and fluid dynamics studies to level the emerging offsets of the radial energy formed in the volume of the facility multiplying part due to the pulsed operation of the D-T neutron plasma source were presented. The results will be useful in improving the power control-based subcriticality monitoring method in coupled systems of the "pulsed neutron source-subcritical fuel assembly" type.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

버스 정류장의 서비스 수준 및 평가모델 구축에 관한 연구 (Establishment about Service Level and Evaluation Model of Bus Stop)

  • 이원규;정헌영
    • 대한토목학회논문집
    • /
    • 제28권2D호
    • /
    • pp.217-225
    • /
    • 2008
  • 버스 정류장은 많은 승객이 이용하기 때문에 편리한 서비스 제공을 위하여 이용자 중심으로 환경을 개선할 필요가 있다. 본 연구는 GAP, IPA, 구조방정식을 이용한 버스 정류장 서비스 수준에 대한 이용자 평가모델 구축을 통하여 그 개선 방향을 제시하고자 하였다. 버스 정류장의 31개 서비스 항목에 대한 GAP 구축에서는 장애인 관련 시설, 버스 이용 관련 정보를 제공하는 항목에서 차이가 높게 나타났다. IPA의 현재 서비스의 경우는 버스 운행 관련 정보, 보조시설, 장애인 지원시설에서 우선 시정이 필요한 것으로 나타났고, 서비스 기대치의 경우는 버스 운행 관련 정보 및 환승시설, 장애인 지원시설에서 지속적 노력이 필요한 것으로 나타났다. 구조방정식에 의한 버스 정류장 서비스 평가모델은 적합도가 좋은 것으로 나타났으며, 버스 정류장 전체 만족도에는 시설 이용 만족보다는 대기 만족 그리고 버스 정류장 시설 이용 만족에는 버스 운행 관련 정보 만족, 보조시설 만족, 버스 운행 정보 및 환승시설, 장애인 지원시설이 상대적으로 영향을 많이 미치는 것으로 나타났다. 그리고 현재 버스 정류장에 대한 전체 만족도가 낮을수록, 전체 만족도에 대한 기대치가 높게 요구되고 있는 것으로 나타났다. 따라서 버스 운행 관련 정보와 장애인 지원시설에 대해서는 적극적인 개선 전략이 필요한 것으로 나타났다.

온실가스 감축 전략의 성과평가 - 지자체 환경기초시설 사례 - (Assessment of GHG Reduction Strategy - A Case of Environmental Facilities of Incheon City -)

  • 장종옥;이성욱;김종대
    • 한국환경과학회지
    • /
    • 제26권4호
    • /
    • pp.509-519
    • /
    • 2017
  • The study focuses on 32 environmental facilities in Incheon Metropolitan City, South Korea, categorizes them by sector: sewage treatment, wastewater treatment, incineration, landfill, water purification, and water supply. Their GHG reduction results are analyzed through quantitative and qualitative measures for 2012 to 2015. The study surveys and examines GHG reductions of the environmental facilities for two categories - facility operation and management. The findings are as follows: First, the GHG reduction rate, an emission-to-allocation ratio, from 2012 to 2015 is 89.67%. Second, GHG reductions coming from qualitative measures of facility management are even greater than those from quantitative measures of facility operation. Third, GHG reductions through facility operation are mostly attributable to overhauls, less use of facilities, resources recycling, process improvement rather than the betterment of fuels, facilities and energy efficiency. Fourth, higher reduction can be achieved by effective facility management, qualitative measures.

초.중등 교육시설의 유지관리비 분석 - 인천광역시 초.중등학교를 중심으로 - (The Analysis of Maintenance & Repair Cost in Educational Facilities of Primary and Secondary Schools - Focusing on Primary and Secondary Schools in Incheon Metropolitan City -)

  • 김영구;이재림
    • 교육시설
    • /
    • 제16권1호
    • /
    • pp.33-41
    • /
    • 2009
  • The purpose of this study is to provide a basis for calculation of school operation fees for normal functioning of the school facilities, and facility maintenance and repair cost through their life spans, considering remodeling of the facilities and changes of their functions. This study analyzes maintenance and repair records during the three years from 2003 to 2005 in primary, middle and high schools in Incheon Metropolitan city and also the facility management and operation expenditure of the same schools in the city during the year of 2005, and presents quantified unit cost of each item according to the area, the age of the facilities, and the number of classroom, student, and lessons given. The calculation can be a basis for both BTL school facility managers and the general school facility mangers to budget school facility maintenance cost appropriately and the quantity of energy, water, electricity, and telephone fees calculated here can be a criteria for the managers to check the normal maintenance of their facility.

A Study on the Purification of Water-Pool in Irradiated Materials Examination Facility

  • Song, Ung-Sup;Lee, Jong-Heon;Lee, Hong-Gyee;Hong, Kyon-Pyo
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.42-50
    • /
    • 2004
  • The pool $(3m{\times}6m{\times}10m{\times}$ in Irradiated Materials Examination Facility is generally used to transport irradiated materials between a moving cask and hot-cell. During the operation in the pool such as loading/unloading the cask, holding specimen and bucket elevation, water maybe contaminated by radioactive or contaminated impurities from irradiated materials. Then, it must be purified and filtered continuously to keep lower radioactivity than that of regulation prescribed by RCA Korea Activity in a part of radioactive contamination control. This paper described radioactive contamination distribution of water as transported materials, which is related to effective operation of purification and filtration system.

  • PDF