• Title/Summary/Keyword: Facility Criteria

Search Result 527, Processing Time 0.029 seconds

A Study on the Decision Making for Evaluating the Outworn Facility Replacement in Shipbuilding (조선 노후설비교체 타당성 분석을 위한 의사결정에 관한 연구)

  • Lee, Min-Woo;Ko, Dong-Chan;Park, Ju-Chull
    • IE interfaces
    • /
    • v.14 no.3
    • /
    • pp.310-317
    • /
    • 2001
  • The purpose of this study is to investigate and to develop a decision support system for supporting the outworn facility replacement analysis in shipbuilding. This paper also provides an information system which can be effectively applied to various criteria in decision making. The modelbase of decision support system uses the concepts of the analytic hierarchy process along with an appropriate scoring methods. The AHP represents an improvement over other well-known scoring approaches since the criteria weights of priorities established by the AHP are not based on arbitrary scales, but use a ratio scale for human judgements. The proposed methodology in this research enables the decision maker to evaluate the investment alternatives based on qualitative data and quantitative data in a systematic way.

  • PDF

A Case Study on the Design for Jeong-eup Second Safety Evaluation Tentative Research Institute (안전성평가연구소 정읍제2안전성평가시험연구동 설계사례)

  • Jung, Jong-Lim;Oh, Kun-Hyoan;Jung, Jae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.552-557
    • /
    • 2008
  • This paper introduces to schematic design for Korea Institute of Toxicology Second Campus at Jeong-eup and provides fundamental information and data in order to design this laboratory facility to meet the criteria of G.L.P(Good Laboratory Practice), AAALAC(Association for Assessment and Accreditation of Laboratory Animal Care) and so on. This paper especially focus on design criteria, HVAC(Heating Ventilating and Air Conditioning) equipment and systems, plumbing equipment and systems, maintenance of equipment and systems and energy saving system of this laboratory facility.

  • PDF

A Study on Green Building Certification Criteria of Educational Facilities based on LEED Certified Cases (LEED 인증사례 분석을 통한 교육시설의 녹색건축 인증기준에 관한 연구)

  • Ahn, Dong-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.122-132
    • /
    • 2014
  • Sustainability became the keyword of our society worldwide, and it is undoubtful that buildings are mainly responsible for green house gas emission and energy consumption. Among different project types, educational facility was selected in this study to find out what needs to be addressed in order to provide students better learning environments. Scorecards from 32 LEED certified school projects went through analysis and essential components as design strategies in sustainable educational facilities were extracted based on application rate of each credit in LEED for School(2009). The extracted data were further analyzed in comparison with related components in G-SEED. The results would be used as guidelines for those of who design sustainable education facilities and prepare green building certifications. and it would further foster architect's responsibility towards green society in Korea.

A Case Study on the Safety Assessment for Groundwater Pathway in a Near-Surface Radioactive Waste Disposal Facility

  • Park, Joo-Wan;Chang, Keun-Moo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.232-241
    • /
    • 2002
  • A safety assessment is carried out for the near-surface radioactive waste disposal in the reference engineered vault facility. The analysis is mainly divided into two parts. One deals with the release and transport of radionuclide in the vault and unsaturated zone. The other deals with the transport of radionuclide in the saturated zone and radiological impacts to a human group under well drinking water scenario. The parameters for source-term, geosphere and biosphere models are mainly obtained from the site specific data. The results show that the annual effective doses are dominated by long lived, mobile radionuclides and their associated daughters. And it is found that the total effective dose for drinking water is far below the general criteria of regulatory limit for radioactive waste disposal facility.

A Study on the Decision-making of Minimax Facility Location (Minimax에 의한 설비입지의 의사결정에 관한 연구)

  • 전만술;이성옥
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.8 no.12
    • /
    • pp.1-6
    • /
    • 1985
  • The purpose of this study is to consider the criteria for decision-making of facility location in view of Minimax. As an illustration of the location of storerooms in a manufacturing plant that minimizes the maximum distance workers must travel to reach a storeroom, the number and variety of location problems that can be formulated appropriately as minimax problems are sizable. A minimax solution can be interpreted as a grease the squeaky wheel solution In solving a minimax location problem, costs other than the maximum cost are not considered.

  • PDF

A Study on the Derivation of the User-Oriented Agricultural Drought Assessment Criteria Using the AHP technique (AHP기법을 이용한 수요자 중심의 농업가뭄 영향 평가 기준 도출 연구)

  • Lee, Suk-Ju;Song, Jae-Do;Jang, Tae-Il;Sul, Dong-Moon;Son, Jae-Kwon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 2018
  • Currently in the drought evaluation, which is a supplier-oriented standard that applies storage rates of reservoirs, evaluation for users that use agricultural water is not done. Therefore, this study established drought evaluation items for drought evaluation based on farmers' judgement, conducted a survey on farmers and experts, compared and analyzed weighted value between two groups, and then classified the evaluation standards per each evaluation item. The agricultural drought evaluation items are 5 major items of water supply lapse rate, agricultural weather, agricultural irrigation facility, crop and soil, and 12 subsections for regional characteristics and opinions of consumers that use water to be reflected. The result of analyzing weighted value of farmers and experts' major items shows that farmers is agricultural irrigation facility(0.219), water supply lapse rate(0.211), agricultural weather(0.204), crop(0.183) and soil(0.183). Experts is agricultural weather(0.297), agricultural irrigation facility(0.202), water supply lapse rate(0.189), crop(0.162) and soil(0.150), which displays difference between the two groups. The agricultural drought criteria standards are established based on precedent studies and cases, and grades of evaluation items are 1st grade(extreme stage), 2nd grade(warning stage), 3rd grade(alert stage) and 4th grade(attention stage). The above analysis per each consumer-oriented agricultural drought evaluation item and the analysis on the standards of evaluation grades are expected to be used as a basic resource for establishing agriculture drought policy and selecting drought area in the future.

Suggestion on Screening Concept of Radionuclides to be Considered for the Radiological Safety Assessment of the Domestic KBS-3 Type Geological Disposal Facility of High-level Radioactive Waste(HLW) (국내 KBS-3 방식 고준위방사성폐기물 심층처분시설 방사선학적 안전성 평가 대상 방사성핵종 목록 선정개념(안) 제언)

  • Sukhoon Kim;Donghyun Lee;Dong-Keuk Park
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.45-59
    • /
    • 2023
  • The transport calculation for a wide variety of radionuclides contained in high-level radioactive waste, especially spent nuclear fuel, is computationally difficult, and input data collection for this also take a considerable amount of time. Accordingly, considering limited resources, it is possible to reduce the calculation time while minimizing impact on accuracy by including only radionuclides important to calculation result through applying some criteria among potential radiation source terms that may release into environment. In this paper, therefore, we reviewed and analyzed the screening process performed to select radionuclides to be considered in the safety assessment for the KBS-3 type repository in Sweden and Finland. In both countries, it was confirmed that a list of radionuclides was selected by comprehensively considering screening criteria such as radioactivity inventory, half-life, radiotoxicity, risk quotient, and transport properties, and etc. A comparison of radionuclides included in the radiological safety assessment in both countries suggests that most of nuclides are considered in common, and a few nuclides considered only in one country are due to differences in decay chain treatment or spent fuel types. As of now, since most of information on the disposal facility in Korea has not been determined, it is necessary to comprehensively model release and transport of all radionuclides considered in Sweden and Finland when performing the radiological safety assessment. Based on these results, we derived the screening concept of selecting a list of radionuclides to be considered in the radiological safety assessment for the domestic KBS-3 type geological disposal facility, and this result is expected to be used as technical basis for confirming conformity with the safety objective. In a more detailed evaluation reflecting domestic characteristics in the future, it would be desirable to consider only radionuclides selected in accordance with the screening procedure. However, further research should be conducted to determine the quantitative limit for each criteria.

The Analysis of Maintenance & Repair Cost in Educational Facilities of Primary and Secondary Schools - Focusing on Primary and Secondary Schools in Incheon Metropolitan City - (초.중등 교육시설의 유지관리비 분석 - 인천광역시 초.중등학교를 중심으로 -)

  • Kim, Young-Gu;Lee, Jae-Rim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.1
    • /
    • pp.33-41
    • /
    • 2009
  • The purpose of this study is to provide a basis for calculation of school operation fees for normal functioning of the school facilities, and facility maintenance and repair cost through their life spans, considering remodeling of the facilities and changes of their functions. This study analyzes maintenance and repair records during the three years from 2003 to 2005 in primary, middle and high schools in Incheon Metropolitan city and also the facility management and operation expenditure of the same schools in the city during the year of 2005, and presents quantified unit cost of each item according to the area, the age of the facilities, and the number of classroom, student, and lessons given. The calculation can be a basis for both BTL school facility managers and the general school facility mangers to budget school facility maintenance cost appropriately and the quantity of energy, water, electricity, and telephone fees calculated here can be a criteria for the managers to check the normal maintenance of their facility.

Plan to Develop the Radioactive Waste Certification Program (방사성폐기물인증프로그램 개발 방안)

  • Chung Hee-Jun;Lee Jae-Min;Whang Joo-Ho;Kim Heon;Jeong Yi-Yeong
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.205-210
    • /
    • 2005
  • The proposed regulation for low and intermediate level radioactive waste disposal facility, scheduled to be revised, recommends that the waste generator should verify the radioactive waste conforms to the disposal requirements before disposing of it. According to the regulation, the radionuclide concentration of the radioactive waste, and its physical and chemical characteristics and safety must be confirmed prior to the disposal of low and intermediate level radioactive wastes, and the waste generator is required to deliver this information to the disposal facility operator. In addition, the disposal facility operator must assess the safety of the disposal site to establish the SWAC (Site Specific Waste Acceptance Criteria) in consideration of the characteristics of the site, whereas the waste generator must comply with the criteria in managing, disposing of and delivering low and intermediate level radioactive wastes. To abide by the afore-mentioned regulation and criteria, the waste generator must verify that the radioactive wastes to be disposed of are suitable for disposal before they are transported to the disposal facility, and to this end a radioactive waste certification program must be developed. This study conducted an in-depth analysis of the radioactive waste certification programs enforced in countries advanced in atomic energy to develop a draft of a certification program applicable to local power plants, and the program is currently applied as pilot to Uljin Power Plants No. 1 & 2 to prove its applicability. This study is going to analyze the results of the pilot application with a view to developing a radioactive waste certification program suitable to local conditions.

  • PDF