• 제목/요약/키워드: Facial bone fracture

검색결과 206건 처리시간 0.026초

환악 결찰술을 이용한 소아 하악 골절의 보존적 치료: 증례보고 (The conservative treatment of mandibular fracture in a child with circummandibular wiring: case report)

  • 김형모;김태완;송승일;이정근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.145-148
    • /
    • 2010
  • Maxillofacial injuries are less common in children than in adolescents and adults. This lower incidence is a result of the relatively small size of mandible, the resilient nature of the bones, and a relatively protected environment, which distinguish the treatment principles of pediatric mandibular fractures from those of the adult. The bone of child is malleable, so pediatric fractures tend to be less displaced and rarely comminuted. Moreover, high regeneration potential of the wound allows more conservative treatment modalities for the pediatric mandibular fracture. High risk of damaging unerupted tooth bud renders many clinicians to resort to more conservative treatment modality for the reduction of displaced segments. This case report describes two successful treatment cases using the circummandibular wiring which was applicated to the fracture on parasymphysis of mandible. Circummandibular wiring can protect the tooth buds, and there is no need for intermaxillary fixation so that it prevents the possible complications of intermaxillary fixation such as the temporomandibular joint ankylosis and the facial growth disturbances. The acrylic splint was removed after 3 weeks, which showed clinically good union across the fracture line without complications. They showed complete clinical and radiological bone healing with an optimum occlusion.

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.

대학병원 응급실로 내원한 치과 응급환자에 관한 임상적 연구 (A clinical study on the dental emergency patients visiting an University Hospital emergency room)

  • 장창수;이창연;김주원;임진혁;김좌영;김영희;양병은
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권6호
    • /
    • pp.439-447
    • /
    • 2011
  • Introduction: In today's society, the rapid and appropriate care of the dental emergency patients is much more important. So, a retrospective study on the characteristics of emergency dental injuries and diseases will be very meaningful. Materials and Methods: This retrospective clinical study was carried by reviewing the radiographic films and emergency chart of 11,493 patients who had visited the emergency room of Hallym Sacred heart Hospital and were treated in the Department of Oral and Maxillofacial Surgery from January 2006 to December 2010. Results: The male to female ratio was 1.9:1. The highest monthly incidence was observed in May (10.4%) and June (8.9%) and the peak age distribution was the first decade (56.0%), followed by the second decade (16.0%). Trauma was the most common cause in dental emergency patients, followed in order by toothache, odontogenic infection, temporomandibular joint (TMJ) disorder and oral hemorrhage. Soft tissue injury was most prevalent in the trauma group, followed by tooth injury and facial bone fractures. In the tooth injury group, tooth fracture (56.7%) showed the highest incidence followed in order by tooth subluxation (18.2%), tooth concussion (16.9%), tooth avulsion (11.5%) and alveolar bone fractures (3.7%). In the facial bone fracture group, mandibular fractures (81.8%) showed the highest incidence followed in order by maxilla fractures (15.7%), nasal bone fractures (9.0%), zygomaticomaxillary complex fractures (5.4%), orbital bone fractures (2.5%). In mandibular bone fractures, the most common location was the symphysis (70.1%), followed in order by the mandibular angle (33.0%), mandibular condyle (22.8%) and mandibular body (13.6%). In the infection group, a submandibular space abscess (46.2%) was most common followed in order by a buccal space abscess (17.4%), canine space abscess (16.9%) and submental space abscess (12.3%). TMJ dislocation (89.3%) showed the highest incidence in the TMJ disorder group, followed by TMJ derangement (10.7%). In the other group, a range of specific symptoms due to post operation complications, trigeminal neuralgia, chemical burns and foreign body aspiration were reported. Conclusion: For the rapid and appropriate care of the dental emergency patients, well-organized system should be presented in oral and maxillofacial surgery. And it is possible under analysis of pattern and the variation of the dental emergency patients.

Carved Merocel®을 이용한 비골골절의 고정 (Fixation of Nasal Bone Fracture with Carved Merocel®)

  • 공정식;정재아;강소라;김양우;전영우
    • 대한두개안면성형외과학회지
    • /
    • 제12권2호
    • /
    • pp.93-96
    • /
    • 2011
  • Purpose: In most cases of nasal bone fracture, closed reduction with internal or external splint fixation approach is selected. However, because of indiscriminate insertion of the internal splint without considering of anatomical difference or deformity, insufficient fixation happens frequently that need additional fixation. Therefore, we suggest a new method for providing adequate support in reduced nasal bone by carving $Merocel^{(R)}$ that is fixed for the anatomical structure. Method: Closed reduction and internal fixation with carved $Merocel^{(R)}$ was performed in 15 nasal bone fracture patients from March, 2010 to July, 2010. Each patient was evaluated by physical examination, facial photographic check, simple X-ray, and computerized tomography. On the first day post-operation, location of packing and amount of reduction were checked by follow up X-ray and computerized tomography. In addition, patients' symptoms were evaluated. During the 3-month post-op follow up at out-patient clinic, operator, 2 doctors in training and one assistant performed the objective evaluations by physical examination on nasal dorsal hump, nasal deviation, nasal depression, nasal breath difficulty, and nasal airway obstruction. A survey of subjective patients' satisfaction in 4-stages was also performed. Results: The results of follow-up computerized tomography of the 15 patients revealed that 11 patients had good reduced state. Three patients with combined maxillary frontal process fracture had over reductions. A survey performed on the first day post-operation showed that 14 of 15 patients answered that their current symptoms were more than tolerable. At the 3-month follow-up physical exam, one case had a dorsal hump. However, there were no nasal deviations, nasal depressions, nasal breath difficulties, or nasal airway obstructions. Twelve of the 15 patients answered more than moderate on the 3-month survey. Conclusion: Intranasal packing after carving the $Merocel^{(R)}$ considering anatomical structure is a new effective method to promote proper-reduction, maintain stability, and minimize patients' symptoms by addition of a simple procedure.

Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석 (Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method)

  • 강수홍;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

생체흡수성 재료를 이용한 하악골절 치료의 결과 (The Result of Mandible Fracture Fixations with Biodegradable Materials)

  • 왕재권;은석찬;허찬영;백롱민;민경원
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures. Methods: In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw($INION^{(R)}$) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment. Results: In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily. Conclusion: There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

하악골 골절시 사용되는 TRANSBUCCAL TROCAR TIP의 새로운 고안 (DESIGN OF TRANSBUCCAL TROCAR TIP USED IN MANDIBULAR ANGLE FRACTURES)

  • 안병근;이건주;한호진;박형태
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권1호
    • /
    • pp.87-92
    • /
    • 1989
  • Transbuccal trocar has been an established method of fixation for the bone plate in the case of mandibular angle fracture. Other than extraoral approaches, this transbuccal approach has many advantages in the treatment of the fracture of mandibular angle. These advantages are as follows ; (1) Damage to the facial nerve branches is minimal. (2) Less postoperative scar is formed. (3) Good vision of occlusion can be easily obtained on the entire operation. (4) Shorter operation time is needed. But, in the clinical procedure of plate fixation, it is has a difficulty in manipulation of the plate and correction of position. To solve these problems, we designed and used a trocar tip which can be easily attached to the trocar, and could make an improvement in the clinical procedures.

  • PDF

Retrobulbar Hematoma in Blow-Out Fracture after Open Reduction

  • Cheon, Ji Seon;Seo, Bin Na;Yang, Jeong Yeol;Son, Kyung Min
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.445-449
    • /
    • 2013
  • Retrobulbar hemorrhage, especially when associated with visual loss, is a rare but significant complication after facial bone reconstruction. In this article, two cases of retrobulbar hematoma after surgical repair of blow-out fracture are reported. In one patient, permanent loss of vision was involved, but with the other patient, we were able to prevent this by performing immediate decompression after definite diagnosis. We present our clinical experience with regard to the treatment process and method for prevention of retrobulbar hematoma using a scalp vein set tube and a negative pressure drainage system.

Reconstruction of a pathologic fracture following osteomyelitis of the mandible using a fibula osteocutaneous flap

  • Kim, Taeki;Kim, Junhyung;Choi, Jaehoon;Jo, Taehee;Shin, Hyeong Chan;Jeong, Woonhyeok
    • 대한두개안면성형외과학회지
    • /
    • 제22권2호
    • /
    • pp.105-109
    • /
    • 2021
  • The use of a fibula osteocutaneous flap is currently the mainstay of segmental mandibular reconstruction. This type of flap is used to treat tumors, trauma, or osteoradionecrosis of the mandible. However, a fibula osteocutaneous flap may also be a good option for reconstructing the mandible to preserve oropharyngeal function and facial appearance in cases of pathological fracture requiring extensive segmental bone resection. Chronic osteomyelitis is one of the various causes of subsequent pathologic mandibular fractures; however, it is rare, and there have been few reports using free flaps in osteomyelitis of the mandible. We share our experience with a 76-year-old patient who presented with a pathologic fracture following osteomyelitis of the mandible that was reconstructed using a fibula osteocutaneous flap after wide segmental resection.