• 제목/요약/키워드: Face to Bottom

검색결과 117건 처리시간 0.025초

파쇄대를 통과하는 해저터널의 수리거동에 관한 연구 (Hydraulic behavior of a subsea tunnel in a ground with fractured-zones)

  • 신종호;최규철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1571-1580
    • /
    • 2008
  • Subsea tunnels that link land to island and among nations for transportation, efficient development of limited surface and pursuit of economic development should be designed to support pore water pressure on the lining. It is generally constructed in the bed rock of the sea bottom. When the tunnel excavation face meets fractured-zones below sea bottom, collapse may occur due to an increase of pore water pressure and large inflow. Such an example can be found in the Norwegian subsea tunnel experiences in 1980's. In this study hydraulic behavior of tunnel heading is investigated using numerical method based on the collapse of Norwegian subsea tunnel. The effect of pore water pressure and inflow rate were mainly concerned. Horse-shoe shaped model tunnel which has 50 m depth from the sea bottom is considered. To evaluate hydraulic performance, parametric study was carried out for varying relative permeability. It is revealed that pore water pressure has increased with an increase of sea depth. Especially, at the fractured-zone, pore water pressure on the lining has increased significantly. Inflow rate into tunnel has also increased correspondingly with an increase in sea depth. S-shaped characteristic relation between relative permeability and normalized pore water pressure was obtained.

  • PDF

CT시험편의 Back Face Strain Compliance 평가 (Evaluation of a Back Face Strain Compliance of CT specimen)

  • 김원범
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.686-691
    • /
    • 2016
  • 용접강구조물에서는 용접비드와 같은 응력집중부가 많이 존재한다. 또한 용접부에서는 용접결함이 발생할 가능성이 많다. 반복적인 피로하중이 응력집중부에 작용하면 응력집중부에서 피로균열이 발생하고, 발생된 균열의 전파에 의해 피로파괴사고를 일으킨다. 따라서 피로파괴사고를 미연에 방지하기 위하여 균열발생수명과 균열전파수명과 같은 피로수명의 파악이 필요하다. 본 연구에서는 피로균열전파특성 연구에 사용되는 컴플라이언스를 도출하였다. 이 컴플라이언스는 피로균열의 자동화 측정에 활용할 수 있다. 본 연구에서는 CT시험편에 대하여 in-house FEM program을 사용하여 컴플라이언스를 계산하였다. 이 계산결과는 저자의 앞선 연구에서 본 프로그램을 사용하여 계산한 J integral의 계산결과와 대비하여 a/W와의 관계를 제시하였다. 그리고 또한 CT시험편 Back Face의 중앙부로부터 위아래 방향의 스트레인 분포에 계산을 실시하였다. 이 분포에서는 중심으로부터 위아래로 갈수록 스트레인이 감소하는 경향을 나타내었다. 이상의 계산과정으로부터 균열진전시험의 자동수행을 위한 컴플라이언스를 얻을 수 있었다. 이것으로부터 CT 시험편의 피로균열진전시험의 자동화에 활용이 가능하게 되었다.

레일-휠의 접촉면 경사도에 따른 응력-변위량의 거동특성에 관한 연구 (A Study on the Contact Behavior of Stress-Displacement Characteristics for an Inclined Rail-Wheel Contact Mode)

  • 김청균
    • 한국철도학회논문집
    • /
    • 제7권3호
    • /
    • pp.186-192
    • /
    • 2004
  • Using the finite element method, rail-wheel contact model has been analyzed for mechanical loads due to passengers and payload of the train. This paper presents an investigation on how tapered wheel and inclined rail surfaces affect the contact stress and displacement of rail-wheel contacting surface under mechanical loads. For a numerical analysis, the tapered faces of the wheel are considered as 2.5% and 5.5%. And two models of the tilted rail are also considered as 40:1 and 20:1 at the bottom of the rail. The computed results based on the contact stress and displacement FE analysis indicate that the tilting ratio of the rail, 20:1 with a tapered face of the wheel, 2.5% may be more stable compared to that of 40:1 tilting model and 5.5% tapered wheel face.

Nonlinear magneto-electro-mechanical vibration analysis of double-bonded sandwich Timoshenko microbeams based on MSGT using GDQM

  • Mohammadimehr, M.;Shahedi, S.
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.1-36
    • /
    • 2016
  • In the present study, the nonlinear magneto-electro-mechanical free vibration behavior of rectangular double-bonded sandwich microbeams based on the modified strain gradient theory (MSGT) is investigated. It is noted that the top and bottom sandwich microbeams are considered with boron nitride nanotube reinforced composite face sheets (BNNTRC-SB) with electrical properties and carbon nanotube reinforced composite face sheets (CNTRC-SB) with magnetic fields, respectively, and also the homogenous core is used for both sandwich beams. The connections of every sandwich beam with its surrounding medium and also between them have been carried out by considering Pasternak foundations. To take size effect into account, the MSGT is introduced into the classical Timoshenko beam theory (CT) to develop a size-dependent beam model containing three additional material length scale parameters. For the CNTRC and BNNTRC face sheets of sandwich microbeams, uniform distribution (UD) and functionally graded (FG) distribution patterns of CNTs or BNNTs in four cases FG-X, FG-O, FG-A, and FG-V are employed. It is assumed that the material properties of face sheets for both sandwich beams are varied in the thickness direction and estimated through the extended rule of mixture. On the basis of the Hamilton's principle, the size-dependent nonlinear governing differential equations of motion and associated boundary conditions are derived and then discretized by using generalized differential quadrature method (GDQM). A detailed parametric study is presented to indicate the influences of electric and magnetic fields, slenderness ratio, thickness ratio of both sandwich microbeams, thickness ratio of every sandwich microbeam, dimensionless three material length scale parameters, Winkler spring modulus and various distribution types of face sheets on the first two natural frequencies of double-bonded sandwich microbeams. Furthermore, a comparison between the various beam models on the basis of the CT, modified couple stress theory (MCST), and MSGT is performed. It is illustrated that the thickness ratio of sandwich microbeams plays an important role in the vibrational behavior of the double-bonded sandwich microstructures. Meanwhile, it is concluded that by increasing H/lm, the values of first two natural frequencies tend to decrease for all amounts of the Winkler spring modulus.

Foodborne Pathogen Reduction을 위한 항균제의 새로운 Delivery System인 Aerosolization

  • 오세욱;강동현
    • 식품기술
    • /
    • 제18권1호
    • /
    • pp.91-98
    • /
    • 2005
  • Aims: As a preliminary experiment on new sanitizer delivery tools, the efficacy of aerosolizedsanitizer on foodborne pathogens was investigated in larger model chamber system.Methods: Peroxyacetic acid and hydrogen peroxide were aerosolized in a model system againstartificially inoculated target microorganisms on laboratory media. Cultures of 4 different foodborne pathogens were inoculated and affixed onto 3 different heights (bottom, wall, and ceiling), and 3different orientations (face-down, vertical, and face-down) inside a commercial semi-trailer cabinet(14.6 x 2.6 x 2.8 m). Sanitizer was aerosolized into 2 m droplet size fog and treated for 1 h atambient temperature.Results: Populations of Bacillus cereus, Listeria innocua, Staphylococcus aureus, and Salmonellatyphimurium were reduced by an average of 3.09, 7.69, 6.93 and 8.18 log units per plate, respectively.Interestingly, L. innocua, Staph. aureus, and Salm. typhimurium showed statistically not different (P$\leq$ 0.05) reduction patterns relative to height and orientation that were never expected in a sprayingsystemConclusion and significance: Aerosolized sanitizers diffuse like gaseous sanitizers, so it has greatpotential for use in commercial applications.

  • PDF

진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가 (Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test)

  • 하익수;김용성;서민우;박동순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

표면차수벽형 석괴댐과 락필댐의 내진성능 비교를 위한 진동대시험 (Shaking Table Test for Comparison of Seismic Performance of Concrete-Face Rockfill Dam and Earth Core Rockfill Dam)

  • 하익수;임은상;서민우;김용성
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.3-10
    • /
    • 2005
  • In this study, 1-g shaking table tests on the model of CFR(Concrete-Face Rockfill) type "D" dam in operation and the model of virtual ECRD(Earth Core Rockfill Dam) of which static stability is about the same compared to the model of CFRD were carried out. The purpose of this study is to compare the seismic performance of CFRD and ECRD from the analysis of model test results. Displacement response behavior of the dam was examined through the measurement of vertical and horizontal displacement of model dam crest. Also, amplification characteristics of accelerometers installed with dam height were examined through the measurement of acceleration with dam height. Also, in the case of ECRD, patterns of excess pore pressure generation with dam height were examined. From the test results, it was found that accelerations of dam crest of CFRD and ECRD were amplified about 1.52 times and 2 times compared to the accelerations of dam bottom, respectively. amplification was outstanding at three quarters of dam height from the bottom of dam. This phenomenon was outstanding in case of ECRD. And it was estimated that vertical and horizontal displacement of prototype dam of CFRD were 6.8cm (0.1% of dam height) and 12.3cm (0.2% of dam height), respectively. Also, it was estimated that vertical and horizontal displacement of prototype dam of ECRD were 4.3cm (0.1% of dam height) and 5.5cm (0.11% of dam height), respectively.

  • PDF

파괴 메커니즘을 고려한 내부 포스트텐션 플랫 플레이트 슬래브-기둥 접합부의 강도식 평가 (Strength of Interior Post-Tensioned Flat Plate Slab-Column Connection based on Failure Mechanism)

  • 김민남;하상수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.126-129
    • /
    • 2006
  • A bending moment $M_u$ transferred at slab-column connection is resisted at the slab critical section by flexure and shear. The ACI 318-05 Building Code(1) gives an empirical equation for the fraction ${\gamma}_{\upsilon}$ of the moment $M_u$ to be transferred by shear at the slab critical section at d/2 from the column face and also the effective wide(c+3h). The equation is based on tests of interior slab-column connections without shear reinforcement. In order to investigate the data eight test specimens were examined. The test shows that increased slab load substantially reduces both the unbalanced moment capacity and the lateral drift capacity of the connection. Especially, the specimens with the bottom reinforcement existence and nonexistence, appears remarkable differences. Studies also show that the code equation for ${\gamma}_{\upsilon}$ does not apply to all cases. The purpose of this study is to compare the test results with present ACI 318-05 Building Code provisions for design of slab-column connections and with the analysis of the experimental data for a new limitation of strength equation without shear reinforcement and bottom reinforcement.

  • PDF

Static and dynamic analytical and experimental analysis of 3D reinforced concrete panels

  • Numayr, K.;Haddad, R.
    • Structural Engineering and Mechanics
    • /
    • 제32권3호
    • /
    • pp.399-406
    • /
    • 2009
  • A three-dimensional panel system, which was offered as a new method for construction in Jordan using relatively high strength modular panels for walls and ceilings, is investigated in this paper. The panel consists of two steel meshes on both sides of an expanded polystyrene core and connected together with a truss wire to provide a 3D system. The top face of the ceiling panel was pored with regular concrete mix, while the bottom face and both faces of the wall panels were cast by shotcreting (dry process). To investigate the structural performance of this system, an extensive experimental testing program for ceiling and wall panels subjected to static and dynamic loadings was conducted. The load-deflection curves were obtained for beam and shear wall elements and wall elements under transverse and axial loads, respectively. Static and dynamic analyses were conducted, and the performance of the proposed structural system was evaluated and compared with a typical three dimensional reinforced concrete frame system for buildings of the same floor areas and number of floors. Compressive strength capacity of a ceiling panel is determined for gravity loads, while flexural capacity is determined under the effect of wind and seismic loading. It was found that, the strength and serviceability requirements could be easily satisfied for buildings constructed using the three-dimensional panel system. The 3D panel system is superior to that of conventional frame system in its dynamic performance, due to its high stiffness to mass ratio.

외래간호사의 감정노동 경험 (Emotional Labor Experienced by Ambulatory Care Nurses)

  • 송미라;박금주
    • 간호행정학회지
    • /
    • 제17권4호
    • /
    • pp.451-461
    • /
    • 2011
  • Purpose: The purpose of this study was to explore emotional labor experienced by nurses in ambulatory care setting. Method: The phenomenological method developed by Giorgi was used for this study. The participants were 9 nurses who had experienced emotional labor. Data were collected between May and August 2010 by face-to-face interviews. The interview was recorded and then transcribed. Results: The constituents associated with the meaning of the nurses' experiences of emotional labor in ambulatory care setting were as followings: bearing down of suffering emotions coming up from the bottom, feeling loneliness when having to undertake care alone by oneself, having conflict between nursing professional and services, managing mind by means of both internal and external resources, getting ridding oneself of conflict with forced emotions over time. Conclusions: The results of this study should contribute to a deeper understanding of the meaning of emotional labor experienced by nurses in ambulatory care. The results also highlight the need to develop programs for nurses in ambulatory care setting to help them express their real action.