• 제목/요약/키워드: Facade Planning

검색결과 50건 처리시간 0.023초

Building 3D model using laser scan data

  • Choi, Sung-Hun;Kim, Dong-Seok;Lee, Heung-Jae;Lee, Kwae-Hi
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.101-105
    • /
    • 2002
  • In this paper we describe techniques for the automated creation of geometric correct 3-D models of the building using two 2-D laser scanners. One of the laser scanners is used for position estimation using a scan matching algorithm, while the other is used to build 3-D models of the facade of the buildings. Those models can be used for virtual reality, tele-presence, digital cinematography and urban planning applications. Results are shown for building models in our campus using real data acquired from two sensors.

  • PDF

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

이중외피 시스템의 에너지성능평가를 위한 하절기 열환경 및 자연환기 분석 (Analysis of the Thermal Environment and Natural Ventilation for the Energy Performance Evaluation of the Double Skin System during the Summer)

  • 엄정원;조수;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper discusses thermal and ventilation performance which might be caused by the adoption of one of specific building facade techniques, Double Skin System(DSS). One building with a prototypical DSS was selected and systematically investigated through field monitoring and computer simulation techniques. A network model of ventilation was successfully made using COMIS to evaluate ventilation performance of the system which can hardly be done by field measurements. Various operating conditions of air conditioning on/off and window opening were implemented in this type of building. Through the appropriate operation of the DSS in summer, simulation-based and experimental results implicate that it can lead to cooling energy savings.

옥외광고물 설치를 고려한 복합상업건물 입면개선 - 창원시 일반상업지구를 중심으로 - (The Facade Improvement of Complexed Commercial Building Considering Open Signboard - Focused on Commercial district in Chnagwon -)

  • 유진상;서유석
    • 디자인학연구
    • /
    • 제20권3호
    • /
    • pp.191-202
    • /
    • 2007
  • 최근 들어 옥외광고물에 대한 행정적 규제나 방침이 적용되고 있고 광고물 자체의 디자인이 향상되고 있으나 건축물 유형과 관련한 현실적인 옥외광고물의 상관성 연구는 부족한 실정이다. 그러므로 양자간의 정량적 상관성 분석을 통하여 도심 가로변 복합상업건축물의 디자인 시 옥외광고물의 패턴과 량을 미리 고려하여 입면을 개선하는 방법을 제시해보고자 한다. 매스계획 시에는 첫째, 전면공지형이 바로인접형 보다 옥외광고물 밀도를 낮추는 수단이 된다. 둘째, 전면적이 유사하면 높이차이가 있어도 광고물 수에는 변화가 없는 것으로 밝혀져 4층 이상 건물의 가로형광고물도 허가 시 총량을 제어하는 방안이 도입될 필요성이 제기되었다. 셋째, 동일레벨보다 상승진입형으로 가로와 접하는 건물 옥외광고물의 밀도가 더 낮으므로 입면계획 시 이를 반영하되 가로특성별로 입면레벨 제어가 필요하다. 넷째, 스팬드럴이나 베란다 세장비를 옥외광고물 부착이 어려운 형태로 줄이고 매스 측면모서리에 돌출세로형광고물의 위치를 미리 배려하는 것이 유리하다. 다섯째, 중층부에는 세로형 돌출옥외광고물을, 중 고충부는 광고물이 작은 단위로 분산되지 않도록 큰 면적을 할애해야한다. 입면계획 시에는 첫째, 수직형보다 수평형 벽면과 횡연창이 많으므로 건물의 스팬드럴 위치와 폭을 일정하게 유지하면 이후 정렬된 광고물 설치를 기대할 수 있다. 둘째, 불규칙형 벽면형태가 단일주조형에 비해 오히려 광고물 총량 제어에 유리하다. 셋째, 횡연창이 광고물 총량을 가장 제어하기 힘들며, 복합창의 경우 횡연+종연창 복합형의 광고물이 격자+횡연창이나 격자+전면창에 비해 상대적으로 많으므로 이를 입면계획에 반영해야 한다. 넷째, 전면창복합형>격자창복합형>횡연창 복합형 순으로 광고물 제어에 유리하다. 그러므로 복합상업건축물 입면계획 시 일방적인 수평요소의 반복은 지양할 필요가 있다. 모서리계획 시에는, 첫째, 2개 이상의 가로와 접하는 건물의 경우 모서리부 광고 효과가 지배적이며 대부분 곡선돌출형이 사용되고 있었다. 그러므로 모서리 저층부를 필로티로 계획하여 보행흐름을 원활하게 하고 대신 입면을 투명하게 하여 간접광고(내부전시) 효과를 유도하는 것이 좋다. 특히 원형모서리는 건물 특화 성격이 강하므로 불가피할 경우 소형 액센트 광고 위치를 미리 벽면으로 할애하는 것이 경관 및 입면계획에 유리한 것으로 분석되었다.

  • PDF

Green BIM기반 초기설계 단계에서 타입별 아트리움의 규모산정에 관한 연구 (Analysis on Green BIM based Atrium Sizes in the Early Design Stage)

  • 정승우;이권형;김인한;추승연
    • 한국CDE학회논문집
    • /
    • 제18권1호
    • /
    • pp.58-70
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance atrium in office buildings. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was considered. The result of this research is as follows: First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning the atrium within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

아파트의 실내외 공기질 향상을 위한 주동 배치 계획 연구 (A Study on the Site Planning of an Apartment Complex for Improving the Outdoor and Indoor Air Quality)

  • 신지웅;김태연;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.195-202
    • /
    • 2004
  • This study focuses on the impacts of apartment building arrangements on the outdoor and indoor air quality - the efficiency of natural ventilation in the outside/inside area of an apartment with consideration to the characteristics of an air flow in outside area depending on the types of the arrangements, the main direction of the wind, and the outside wind pressure on the building facade. As indices to evaluate the efficiency of natural ventilation, the concepts of "Age of Air" and "Purging Flow Rate(PFR)" were used in this study. As indices to classify the efficiency of indoor natural ventilation, the mean values of the wind pressure differences between the front and the back elevations of an apartment building were used. The research showed that the PFR of each apartment building arrangement ranges from 0.867 to 3.253. The "minus-shaped" arrangement showed the highest PFR, 2.306; the "zigzag-shaped" arrangement measured 1.889; the "angle-shaped" arrangement measured 1.465, and the "square-shaped" arrangement measured 1.241. Depending on the direction of the wind, the pressure differences range extremely, with variations from 170% to 2300%. Thus, the indoor natural ventilation efficiency can be changed by the pressure differences of the wind, which are sensitive to the main direction of the wind even though the structure and planning of the apartment complexes are the same. Despite the same direction of the wind, even the efficiency can be diverse. This study showed how to predict the most beneficial apartment building arrangement for the profitable natural ventilation efficiency in each direction of the wind.

모듈러 건축의 현황과 활용에 관한 기초연구 - 사례조사 분석을 중심으로 - (A Basic Study on the Application of Modular Construction - Focused on the Analysis of Case Study -)

  • 김재영;이종국
    • 한국주거학회논문집
    • /
    • 제25권4호
    • /
    • pp.39-46
    • /
    • 2014
  • This research was for the investigation and analysis of the illustration of modular construction application which is different use by each school facility since modular construction related examples are rare in domestic situation, and it has a limitation because of its being basic research material for generating the basic form of modular construction. The research results are as followings. First, in case of school facility from illustration investigation results, module measurement of class modulation is as similar as $3m{\times}10m$, but in resident facility the planning of more flexible plane shape can be possible since modules of 6 cases are free and various, and facade form of various types can be appeared by combination of module unit. Second, as a result of the generated characteristics in compared analysis of representative examples, school facilities were highly indicated for movability and duration reduction areas, and the flexibility, economic efficiency, and environment-friendliness was indicated low relatively. Third, the basic planning types of modular construction can be largely divided into layered type, horizontal (straightway) type, and compound type. The layered type has a short traffic line and facility system and is appropriate for the low-rise form unless separate construction method is used since it is susceptible to load. The horizontal type is advantageous for securing an opening since it has wide extent in light but has a long traffic line and facility system. Finally, the compound type can be possible for planning of various forms but needs the combination of various unit modules and traffic line and facility plan for it can be difficult.

Analysis on Green BIM based Atrium Sizes in the Early Design Stage

  • Jeong, Seung-Woo;Lee, Kweon-Hyoyng;Choo, Seung-Yeon
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.260-266
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance according to the types of atrium of office building. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was understood, and the followings are the considerations for designing an atrium. First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning an atria within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

  • PDF

도시 가로공간 가로시설물의 이용실태 개선방안에 관한 연구 - 전주시 상업가로를 중심(中心)으로 - (A Study on the Improvement Plan for the Actual Conditions of use in the Street Facilities of Urban Street Space- With the commercial Street on the Jeonju City -)

  • 박미화;유응교
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.23-30
    • /
    • 2007
  • In Korea, the top priority of the exterior space in the urban commercial street has been put on the road and parking for cars, not on the street for pedestrians, because of the lack of institutional urban planning, the land use of high density, the pursuit of maximum commercial profit, etc. Also, it is true that the form and facade of the street buildings which form the characteristics of the commercial street are regarded as the consumption-stimulating tool and, subsequently, are symbolized for commercial profit. This study starts from the recognition of reality, and, with the perspective of general plan for urban exterior space, tries to improve the environmental design of street space. Also, this study searches the ways to enhance the cultural, art, aesthetic and functional values of a city, as well as the ways to promote commercial activities and to perform commercial symbolism and pedestrian functions. This study aims at exploring the importance of street environmental design and the information of environmental design, so that the problems of current street environment, which generates the disorder and chaos of information, may be solved. Also, this study aims at promoting the continuous development for the future street environmental design and design plan.

서울 은평 뉴타운 1지구 조경설계 (A Landscape Design Proposal for Eunpyeong New Town, Seoul)

  • 김순분;진양교
    • 한국조경학회지
    • /
    • 제33권2호
    • /
    • pp.111-121
    • /
    • 2005
  • The Seoul Housing Corporation pronounced an alternative design competition and a bidding for Eunpyeong New Town in December of 2004. At first many construction companies were interested in the first New Town Project. But at last a few companies had proposed the alternative design and construction cost. This project needed a conjunction of design ideas and technology know-hows. And the client wanted the brand power of construction company. Ultimately the Corporation hoped that the first New Town Project will end up with high quality successfully. This competition had started with the original construction drawings. Then it needed some alternative ideas and the lowest cost. There were two drawings of non changeable part and changeable part. Non changeable parts are structure like housing unit plan, underground parking lots. Changeable parts are outdoor layout, interior design and building facade. So we tried all ideas of landscape technology and design principles within limited guidelines. The author applied new technology like tilted rooftop greening and sustained container greening on high-rise apartment house. This green technology will be the first trial in Seoul and in the world as well. Daewoo Corporation have accumulated greening technology through the researches by national funding since 2002. Through this New Town Project the green technology will go forward step by step.