• Title/Summary/Keyword: FTIR

Search Result 1,368, Processing Time 0.038 seconds

Passive Remote Chemical Detection of SF6 Clouds in the Atmosphere by FTIR (수동형 FTIR 원격화학 탐지기를 이용한 SF6 오염운의 실시간 탐지)

  • Chong, Eugene;Park, Byeonghwang;Kim, Ju Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • Brightness temperature spectra acquired from FTIR(Fourier Transform Infrared)-SCADS (Standoff Chemical Agent Detection System) could be available for detection and identification of the chemical agents and pollutants from different background. IR spectrum range of 770 to 1350 $cm^{-1}$ is corresponding to "atmospheric window". A 2-dimensional(2D) brightness temperature spectrum was drawn from combining each data point through automatic continuous scanning of FTIR along with altitude and azimuth. At higher altitude, temperature of background was decreased but scattering effect of atmospheric gases was increased. Increase in temperature difference between background and blackbody in SCADS at higher temperature causes to increases in peak intensity of $SF_6$. This approach shows us a possibility that 2D visual information is acquired from scanning data with a single FTIR-SCADS.

Study on Fluorine Penetration of Capping Layers using FTIR analysis (FTIR을 이용한 캐핑레이어의 플루오르 침투 특성 연구)

  • Lee, Do-Won;Kim, Nam-Hoon;Kim, Sang-Yong;Kim, Tae-Hyoung;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.300-303
    • /
    • 2004
  • To fill the gap of films for metal-to-metal space High density plasma fluorinated silicate glass (HDP FSG) is used due to various advantages. However, FSG films can have critical drawbacks such as bonding issue of top metal at package, metal contamination, metal peel-off, and so on. These problems are generally caused by fluorine penetration out of FSG film. Hence, FSG capping layers such like SRO(Silicon Rich Oxide) are required to prevent flourine penetration. In this study, their characteristics and a capability to block fluorine penetration for various FSG capping layers are investigated through FTIR analysis. FTIR graphs of both SRO using ARC chamber and SiN show that clear Si-H bonds at $2175{\sim}2300cm^{-1}$. Thus, Si-H bond at $2175{\sim}2300cm^{-1}$ of FSG capping layers lays a key role to block fluorine penetration as well as dangling bond.

  • PDF

Radiometric Calibration of FTIR Spectrometer For Passive Remote Sensing Application (수동형 원격탐지 FTIR 분광계의 Radiometric Calibration)

  • Kim, Dae-Sung;Park, Do-Hyun;Choi, Seung-Ki;Ra, Sung-Woong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.391-395
    • /
    • 2006
  • In this paper, radiometric calibration of a FTIR spectrometer for passive remote sensing application was introduced and verified. Radiometric calibration is a significant signal processing procedure to retrieve the object radiance from the measured spectrum. The object radiance is measured and registered distorted by the detector's responsivity dependent on wavelength and instrument self-emission. Radiance of two temperature points, hot temperature and cold temperature, from a well-controlled blackbody was measured and used to obtain the scale factor and offset factor which are required for radiometric calibration. For gas phase C2H5OH. radiometric calibration was done and verified through comparison of its emission line width and intensity with the standard spectrum.

Measurement of Oxygen by FTIR in Silicon wafer process steps (실리콘 웨이퍼 공정스텝에서 FTIR에 의한 산소의 측정)

  • 김동수;정원채
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.68-71
    • /
    • 2000
  • In this paper, we have measured the oxygen contents by FTIR in silicon wafer various process technology(slicing, lapping, polishing). The measured data are also compared with the data of etching process(KOH, Bright etching). Also we have measured the surface morpology in backside silicon wafer after etching treatment and etch pit density due to OISF after 4 step high temperature annealing process with optical microscope.

  • PDF

Octadecyltrichlorosilane Self-Assembled Monolayers에 따른 FTIR 분석

  • Kim, Jong-Uk;Kim, Heung-Bae
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.43-46
    • /
    • 2007
  • 기존 사용되어온 절연막의 $SiO_2$의 절연특성이 신호의 간섭 등의 문제가 있어서 절연특성을 좋게 하기 위해 낮은 유전상수와 비결정질의 절연막을 요구하고 있다. 본 연구에서는 OTS를 이용하여 액상 상태에서 SAMs를 형성하였으며 FTIR을 이용한 결합구조의 변화를 살펴보았다. OTS 유기물의 함량을 0.1%에서부터 0.9%까지 다르게 혼합하여 희석시킨 유기화합물 용액에 따른 $650\;cm^{-1}$에서 $4000\;cm^{-1}$까지 전구간에 대한 FTIR 스펙트라를 보았다.

  • PDF

Development of a FTIR Spectroscopy for the Determination of Paper Strength

  • Hoang Viet;Nguyen Kien Loi
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.177-180
    • /
    • 2006
  • Inter-fiber bonding is improved by refining resulting in higher Young's modulus. This effect is consistent to the changes of FTIR absorption intensities associated with the hydroxyl groups in the pulp samples. A PLS model, which is established to correlate the FTIR spectral data with the Young's modulus of the pulp samples for predicting the elastic Young's modulus of paper, is statistically robust.

  • PDF

FTIR study of E7 liquid crystals confined to perfluorinated carboxylic acid treated cylindrical cavities of Anodisc membranes

  • Ha, Ki-Ryong;Ahn, Hee-Jun;Yoon, Sung-Kyoun;Lee, Dong-Ho;West, John L.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.369-372
    • /
    • 2004
  • Orientation of E7 liquid crystals(LCs) confined to 200 nm-diameter cylindrical cavities of Anodisc membranes are investigated by FTIR dichroism techniques. The cavity walls of the confining pores are chemically modified with different perfluorinated carboxylic acids (PCA, $C_nF_{2n+1}$COOH, n=3, 4, 5, 6). From the FTIR spectra of PCA treated alumina Anodsic membranes, we found the salt formation between -COOH group of PCA and Anodisc membrane. From the FTIR spectra of LC filled Anodisc membranes, we found abrupt alignment direction change of LC molecules between n=4 and 5 for 1 mM PCA treated Anodisc membranes, from parallel to perpendicular direction to the cavity walls. But 5mM PCA treated Anodisc membranes, alignment direction of LC molecules changed between n=3 and n=4, from parallel to perpendicular direction.

  • PDF

Removal of Pb2+ ion from aqueous solution Using crab shell treated by acid and alkali (산-염기 처리한 게 껍질에 의한 수풍의 납 이온 제거)

  • 김동석
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.469-476
    • /
    • 2003
  • In order to examine the pre-treatment effect of crab shell en Pb$^{2+}$ removal by crab shell in aqueous solution, acid and alkali pre-treated crab shell were used. Electron microscopy techniques such as TEM (transmission electron microscopy) and SEM (scanning electron microscopy), and EDX (energy dispersive X-ray) and FTIR (Fourier transform infrared) spectrometry techniques were used to investigate the process of Pb$^{2+}$ removal by acid and alkali pre-treated crab shell. The Pb$^{2+}$ removal by acid pre-treated crab shell was much lower than that by untreated crab shell because of the decrease of CaCO$_3$ from the crab shell. However, the Pb$^{2+}$removal by alkali pre-treated crab shell increased compared to that by untreated crab shell. The results were confirmed by TEM, SEM, EDX and FTIR.nd FTIR.

Correlation between Physico-Mechanical and Rheological Properties of Rubber Compounds Based on NR-BR with C-C Gel Content in Polybutadiene (NR-BR 기반 고무소재에서 폴리부타디엔의 C-C 겔 함량과 물리기계적, 유변학적 특성 사이의 상호관계)

  • Ganjali, Saeed Taghvaei;Motiee, Fereshteh;Tabatabaie, Zohreh Ghazi
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.425-433
    • /
    • 2014
  • In this study, microstructure and gel content (C-C) of polybutadiene rubber (PBR) were investigated using various techniques including ASTM D 3616, attenuated total reflectance Fourier transform infrared spectrometry (ATR FTIR), differential scanning calorimetry (DSC) and nuclear magnetic resonance spectroscopy (NMR). The ATR FTIR spectra of the samples were investigated to determine the cis, trans, 1, 2-vinyl and the C-C gel content in PBR. The absorbance ratios of specific peaks in different grades of PBR were correlated with the C-C gel content measured by the ATR FTIR techniques. Physico-mechanical and rheological properties of rubber compounds based on BR with various amounts of gel were determined. The results showed that there is an acceptable correlation between these properties and the C-C gel content of PBR.

FTIR study of E7 liquid crystals confined to cylindrical cavities of Anodisc membranes

  • Ha, Ki-Ryong;Ahn, Hee-Jun;Jung, Kwang-Wook;Ahn, Won-Sool;West, John L.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.475-477
    • /
    • 2003
  • Orientation of E7 liquid crystals (LCs) confined to 200 nm-diameter cylindrical cavities of Anodisc membranes are investigated by FTIR dichroism techniques. The cavity walls of the confining pores are chemically modified with different aliphatic acids ($C_nH_{2n+1}COOH$, n=5, 6, 7, 9). From the FTIR spectra of aliphatic acid treated alumina Anodsic membranes, we found the salt formation between -COOH group of aliphatic acid and Anodisc membrane. From the FTIR spectra of LC filled Anodisc membranes, we found abrupt alignment direction change of LC molecules between n=6 and 7 for 2% aliphatic acid treated Anodisc membranes, from parallel to perpendicular direction to the cavity walls. But 4% aliphatic acid treated Anodisc membranes, alignment direction of LC molecules changed between n=5 and n=6, from parallel to perpendicular direction. The same trend was observed for $^2H-NMR$ measurements.

  • PDF