• Title/Summary/Keyword: FT-NIR spectrometer

Search Result 21, Processing Time 0.028 seconds

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Determination of NaOH, $Na_2CO_3$ and $Na_2S$ Concentration in a Naphtha Cracking Process by FT-NIR Spectroscopy (FT-NIR를 이용한 Naphtha Cracking 공정중 NaOH, $Na_2CO_3$$Na_2S$ 정량분석)

  • Jang, Mijin;Kim, Hyunwook;Cho, Ilyoung
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.448-451
    • /
    • 1998
  • The feasibility of using FT-NIR (Fourier Transform Near Infrared) spectrometer to measure NaOH, $Na_2CO_3$ and $Na_2S$ concentration in a naphtha cracking process, and an outline of the method development to identify spectral feature of the hydroxide whose band is overlapped by a strong water absorption were demonstrated. For measuring NaOH, $Na_2CO_3$ and $Na_2S$, FT-NIR spectrometer is a rapid and possible alternative to the current titration method with a standard deviation of 0.1.

  • PDF

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

Evaluation of Fourier Transform Near-infrared Spectrometer for Determination of Oxalate in Standard Urinary Solution (표준 요 시료 중 Oxalate의 측정을 위한 FT-NIR 분광기의 유용성 검정)

  • Kim, Yeong-Eun;Hong, Su-Hyung;Kim, Jung-Wan;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.165-170
    • /
    • 2006
  • Objectives : The determination of oxalate in urine is required for the diagnosis and treatment of primary hyperoxaluria, idiopathic stone disease and various intestinal diseases. We examined the possibility of using Fourier transform near-infrared (FT-NIR) spectroscopy analysis to quantitate urinary oxalate. The practical advantages of this method include ease of the sample preparation and operation technique, the absence of sample pre-treatments, rapid determination and noninvasiveness. Methods : The range of oxalate concentration in standard urine solutions was $0-221mg/{\ell}$. These 80 different samples were scanned in the region of 780-1,300 nm with a 0.5 nm data interval by a Spectrum One NTS FT-NIR spectrometer. PCR, PLSR and MLR regression models were used to calculate and evaluate the calibration equation. Results : The PCR and PLSR calibration models were obtained from the spectral data and they are exactly same. The standard error of estimation (SEE) and the % variance were $10.34mg/{\ell}$ and 97.86%, respectively. After full cross validation of this model, the standard error of estimation was $5,287mg/{\ell}$, which was much smaller than that of the pre-validation. Furthermore, the MCC (multiple correlation coefficient) was 0.998, which was compatible with the 0.923 or 0.999 obtained from the previous enzymatic methods. Conclusions : These results showed that FT-NIR spectroscopy can be used for rapid determination of the concentration of oxalate in human urine samples.

The study of nondestructive method for measuring the acidity of the recent record paper in Hanji by using FT-NIR spectroscopy and Integrating sphere (푸리에 변환 근적외선 분광분석기(FT-NIR)와 적분구를 이용한 근대 한지 기록물의 산성도 비파괴 평가방법에 대한 연구)

  • Shin, Yong-Min;Park, Soung-Be;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.255-269
    • /
    • 2011
  • The purpose of study has to analyze with non destructive method for researching the tool that could be measured with the status of record written on Hanji speedily. Because the original record should be destructed for analyzing with previous method in the case of the paper record, it was to develop the tool based on non destructive method for overcoming such limit. The study was used with FT NIR (Fourier transform NIR) for analyzing the Hanji for being written and preserved. The FT NIR spectrometer that of NIR spectrometer has the better performance of precision and accuracy than dispersive NIR spectrometer was used. Also the wavelength of FT-NIR was measured with 12,500 to 4,000 $cm^{-1}$, and the integrating sphere as diffuse reflectance type was used for analyzing Hanji. The moisture and acidity (pH) of chemical factors as quality evaluated factor of Hanji was studied for the correlation of NIR spectrum. And then The NIR spectrum was pretreated for showing the coefficients of optimum correlation. MSC and First derivative of Savitzky - Golay was used as pretreated method, and the coefficients of optimum correlation were shown by PLSR(Partial least square regression). And the coefficients of optimum correlation were calculated by PLSR(Partial least square regression). The correlation coefficients of acidity had 0.92 on NIR spectra without pretreatment. Also the SEP of acidity was 0.24. And then The NIR spectra with pretreatment would have more good correlation coefficients ($R^2=0.98$) and more good SEP(=019) on acidity. Therefore the data of correlation coefficients ($R^2$) and SEP with pretreatment was shown to be superior. And NIR spectra data of first derivative had best linearity on the correlation coefficients ($R^2=0.99$) and also SEP(=0.45) was superior. Therefore the correlation coefficients and SEP of first derivative had better than those of NIR spectra of no pretreatment. As such result, it was possible to evaluate the record status of Hanji speedily with integrated sphere and NIR analyzer as non destructive method.

  • PDF

Study on non-destructive sorting technique for lettuce(Lactuca sativa L) seed using fourier transform near-Infrared spectrometer (FT-NIR을 이용한 상추(Lactuca sativa L) 종자의 비파괴 선별 기술에 관한 연구)

  • Ahn, Chi-Kook;Cho, Byoung-Kwan;Kang, Jum-Soon;Lee, Kang-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.111-116
    • /
    • 2012
  • Nondestructive evaluation of seed viability is one of the highly demanding technologies for seed production industry. Conventional seed sorting technologies, such as tetrazolium and standard germination test are destructive, time consuming, and labor intensive methods. Near infrared spectroscopy technique has shown good potential for nondestructive quality measurements for food and agricultural products. In this study, FT-NIR spectroscopy was used to classify normal and artificially aged lettuce seeds. The spectra with the range of 1100~2500 nm were scanned for lettuce seeds and analyzed using the principal component analysis(PCA) method. To classify viable seeds from nonviable seeds, a calibration modeling set was developed with a partial least square(PLS) method. The calibration model developed from PLS resulted in 98% classification accuracy with the Savitzky-Golay $1^{st}$ derivative preprocessing method. The prediction accuracy for the test data set was 93% with the MSC(Multiplicative Scatter Correction) preprocessing method. The results show that FT-NIR has good potential for discriminating non-viable lettuce seeds from viable ones.

A identification of sprayed fire-resistive materials by near-infrared spectroscopy (근적외선 분광 분석법을 이용한 내화뿜칠재 일치성분석)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2011
  • To protect the steel structure in a high story buildings from fire, the sprayed fire-resistive materials are applied during the construction. Current standard methods to check the quality of sprayed fire-resistive materials are real fire test in lab, which take a long time (several weeks) and expensive. In this study, a simple analytical method to check the quality of sprayed fire-resistive materials is developed using Near Infrared Spectroscopy (NIR). Total 9 kinds of sprayed fire-resisted materials and 3 kinds of normal sprayed material sets were used for the analysis. Each set of materials was 50 to 100 samples. Samples are grinded and make a fine powder. The spectral data acquisition was carried out using FT-NIR spectrometer with a integrating sphere. NIR methods successfully identify the sprayed fire resistive materials by a principle component analysis (PCA) after a vector normalization (SNV) pretreatment.

HAND-HELD NIR SPECTROMETRY : STATUS, TRENDS AND FUTURISTIC PROSPECTS

  • McClure, W.F.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1051-1051
    • /
    • 2001
  • In 1989, at the 2nd ICNIRS Meeting in Tsukuba, I projected certain directions for NIR technology would take in the future. Among those projections were: (1) An inrush of companies producing FT-NIR instruments. (2) Hybrid NIR Systems (3) Hand-held NIR Technology. All three thrusts have resulted in numerous commercial offerings over the last 12 years Hand-held technology for all fields is growing at an astonishing rate. To date, NIR work at North Carolina State University has produced four (4) hand-held NIR units for: (1) Nicotine and Moisture in tobacco, (2) Vanillin and Moisture in Vanilla Beans, (3) Protein, Moisture and Nitrogen in plant tissue, (4) Chlorophyll and Moisture in Growing Plants: A NIR Spectrometer for Developing Countries. This paper will discuss these developments, including design and performance data.

  • PDF