• 제목/요약/키워드: FSI Method

검색결과 171건 처리시간 0.023초

Estimation of Beam Mode Frequencies of Co-axial Cylinders Immersed in Fluid by Equivalent Mass Approach

  • Kim, Tae-Wan;Park, Suhn;Park, Keun-Bae
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.1-13
    • /
    • 2003
  • In this study, an effective method to estimate the fundamental frequencies of co-axial cylinders immersed in fluid is proposed. The proposed method makes use of the equivalent mass or density that is derived from the added mass matrix caused by the fluid-structure interaction (FSI) phenomenon. The equivalent mass is defined from the added mass matrix based on a 2-D potential flow theory. The theory on two co-axial cylinders extended to the case of three cylinders. To prove the validity of the proposed method, the eigenvalue analyses upon coaxial cylinders coupled with fluid gaps are peformed using the equivalent mass. The analyses results upon various fluid gap is conditions reveal that the present method could provide accurate frequencies and be suitable for expecting the fundamental frequencies of fluid coupled cylinders in beam mode vibration.

A Study on the Multi-Objective Optimization of Impeller for High-Power Centrifugal Compressor

  • Kang, Hyun-Su;Kim, Youn-Jea
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.143-149
    • /
    • 2016
  • In this study, a method for the multi-objective optimization of an impeller for a centrifugal compressor using fluid-structure interaction (FSI) and response surface method (RSM) was proposed. Numerical simulation was conducted using ANSYS CFX and Mechanical with various configurations of impeller geometry. Each design parameter was divided into 3 levels. A total of 15 design points were planned using Box-Behnken design, which is one of the design of experiment (DOE) techniques. Response surfaces based on the results of the DOE were used to find the optimal shape of the impeller. Two objective functions, isentropic efficiency and equivalent stress were selected. Each objective function is an important factor of aerodynamic performance and structural safety. The entire process of optimization was conducted using the ANSYS Design Xplorer (DX). The trade-off between the two objectives was analyzed in the light of Pareto-optimal solutions. Through the optimization, the structural safety and aerodynamic performance of the centrifugal compressor were increased.

Four-Switch 인버터의 전압 변동 보상 기법을 통한 전동기 운전 기법 (Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm)

  • 이동명
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.59-66
    • /
    • 2013
  • This paper proposes a new voltage reference generation method for Four-Switch Inverters(FSI) with compensation of the neutral DC-link voltage variation. Since FSIs have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, it is required to take account the voltage difference between the top and bottom capacitors. In this paper, to reduce the effect by the voltage variation, reference voltages are modified by adding compensation voltages proportional to the voltage difference between upper and lower capacitors. Simulation results showing control performance of induction and permanent magnet motors demonstrate the validity of the proposed method.

고받음각에서 기동하는 미사일의 공력-구조 연계 해석 (FLUID-STRUCTURE INTERACTION ANALYSIS FOR HIGH ANGLE OF ATTACK MANEUVER MISSILE)

  • 노경호;박미영;박수형;이재우;변영환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.111-114
    • /
    • 2007
  • Computational Fluid Dynamics (CFD) and the Finite Element Method (FEM) are used to perform aerodynamics analysis and structure analysis. For the fluid-structure interaction analysis, each technology should be considered as well. The process of aerodynamics-structure coupled analysis can be applied to various integrated analyses from many research fields. In this study, the aerodynamics-structure coupled analysis is performed for the missile at high angle of attack condition through the use of Computational Fluid Dynamics (CFD) and the Finite Element Method (FEM). For this purpose, the aerodynamics-structure coupled analyses procedure for the missile are established. The results of the integrated analysis are compared with rigid geometry of the missile and the effect of the deformation will be addressed.

  • PDF

식품산업에서 활용되는 식품안전 분석기술의 현황 (Food safety analytical techniques used in food industry)

  • 김영준
    • 식품과학과 산업
    • /
    • 제51권1호
    • /
    • pp.16-25
    • /
    • 2018
  • Recently, the importance of analytical techniques related to food safety is emerging in the food industry due to changes in diet patterns, environmental changes, climate change and consumer's interest in food safety. In particular, food safety accidents in the food industry may cause economic losses such as media reports, product recalls, consumer distrust, and so on. Therefore, a systematic, proactive and comprehensive food safety management system is increasingly required to prevent food safety issues. Efforts to ensure the reliability of food safety are essential by introducing various analysis instruments such as LC, GC, ICP, LC/MS/MS, GC/MS/MS, ICP/MS, PCR, and RT-PCR. In addition, recent food safety analytical techniques used in food industry should be shifted paradigm by developing multi-component simultaneous analytical method, low cost with high efficient analytical method, and eco-friendly method.

Research of the impact of material and flow properties on fluid-structure interaction in cage systems

  • Mehmet Emin Ozdemir;Murat Yaylaci
    • Wind and Structures
    • /
    • 제36권1호
    • /
    • pp.31-40
    • /
    • 2023
  • This paper investigates the mechanical behavior of full-scale offshore fish cages under hydrodynamic loads. To simulate different cases, different materials were used in the fish cage and analyzed under different flow velocities. The cage system is studied in two parts: net cage and floating collar. Analyses were performed with the ANSYS Workbench program, which allows the Finite Element Method (FEM) and Computational Fluid Dynamics (CFD) method to be used together. Firstly, the fish cage was designed, and adjusted for FSI: Fluid (Fluent) analysis. Secondly, mesh structures were created, and hydrodynamic loads acting on the cage elements were calculated. Finally, the hydrodynamic loads were transferred to the mechanical model and applied as a pressure on the geometry. In this study, the equivalent (von Mises) stress, equivalent strain, and total deformation values of cage elements under hydrodynamic loads were investigated. The data obtained from the analyses were presented as figures and tables. As a result, it has been shown that it is appropriate to use all the materials examined for the net cage and the floating collar.

다양한 전착조건에서 제작된 리튬 전극의 특성 연구 (Comparison of Characteristics of Electrodeposited Lithium Electrodes Under Various Electroplating Conditions)

  • 임라나;이민희;김점수
    • 전기화학회지
    • /
    • 제22권3호
    • /
    • pp.128-137
    • /
    • 2019
  • 리튬은 가장 가벼운 금속일 뿐만 아니라 낮은 환원전위(-3.04 V vs. SHE)와 큰 이론용량($3860mAh\;g^{-1}$)을 가지고 있어 차세대 음극 소재로 연구되고 있다. 리튬 금속을 전극으로 사용하는 리튬이차전지의 경우 전지의 효율과 에너지 밀도 극대화를 위해 얇은 두께의 리튬 전극이 필요하지만 기존의 리튬 박을 제조하는 물리적인 압연 방법으로는 일정수준 이하의 두께를 가지는 리튬 박을 제조하는데 한계가 있다. 본 연구에서는 물리적인 방법 대신 전해도금법으로 박막의 리튬을 전착하여 전해도금 시 사용되는 전해액의 종류와 전착 조건이 전착 특성 및 전착된 리튬의 전기화학 특성에 주는 영향을 확인하였다. 전착 전해액의 농도가 높을 수록 리튬 덴드라이트(dendrite) 형성 억제에 유리한 크고 둥근 형태의 리튬 입자를 형성하였으며 우수한 stripping 효율 (92.68%, 3M LiFSI in DME) 을 나타냈다. 전착 속도(전류 밀도)의 경우 속도 증가에 따라 리튬이 길이 방향으로 성장하여 길고 끝이 뾰족한 형태를 가지는 경향을 보였으며, 이로 인한 비표면적 증가로 전착된 리튬 전극의 stripping 효율이 감소(90.41%, 3M LiFSI in DME, $0.8mA\;cm^{-2}$)하는 경향을 확인하였다. 두 종류의 염과 용매를 조합하여 얻은 1.5M LiFSI + 1.5M LiTFSI in DME : DOL (1 : 1 vol%) (Du-Co) 전해액에서 전착된 리튬 전극이 가장 우수한 stripping 효율 (97.26%) 및 안정적인 가역성을 보였으며, 이는 염의 분해물로 구성된 전극 표면 피막의 Li-F 성분이 주는 안정성 향상과 피막의 유연성을 부여하는 DOL 효과에 기인한 것으로 추정된다.

VIV simulation of riser-conductor systems including nonlinear soil-structure interactions

  • Ye, Maokun;Chen, Hamn-Ching
    • Ocean Systems Engineering
    • /
    • 제9권3호
    • /
    • pp.241-259
    • /
    • 2019
  • This paper presents a fully three-dimensional numerical approach for analyzing deepwater drilling riser-conductor system vortex-induced vibrations (VIV) including nonlinear soil-structure interactions (SSI). The drilling riser-conductor system is modeled as a tensioned beam with linearly distributed tension and is solved by a fully implicit discretization scheme. The fluid field around the riser-conductor system is obtained by Finite-Analytic Navier-Stokes (FANS) code, which numerically solves the unsteady Navier-Stokes equations. The SSI is considered by modeling the lateral soil resistance force according to nonlinear p-y curves. Overset grid method is adopted to mesh the fluid domain. A partitioned fluid-structure interaction (FSI) method is achieved by communication between the fluid solver and riser motion solver. A riser-conductor system VIV simulation without SSI is firstly presented and served as a benchmark case for the subsequent simulations. Two SSI models based on a nonlinear p-y curve are then applied to the VIV simulations. Also, the effects of two key soil properties on the VIV simulations of riser-conductor systems are studied.

Effects of blade configuration and solidity on starting torque of Darrieus wind turbine

  • Roh, Sung-Cheoul;Kang, Seung-Hee
    • Wind and Structures
    • /
    • 제32권2호
    • /
    • pp.169-177
    • /
    • 2021
  • This study investigates the effects of blade configuration and solidity of Darrieus wind turbine on the starting torque characteristics. Generally, the configuration of Darrieus wind turbine is divided into Troposkien, parabola, Catenary, Sandia, modified-parabola and straight types. A numerical analysis has been carried out using Multiple Stream Tube (MST) method to investigate the effect of blade configuration and solidity of Darrieus wind turbine on the starting torque under the initial low range of rotational speed. The simulation results show that the starting torque of Darrieus wind turbine varies considerably depending on the blade configuration. The initial starting torque was larger with Troposkien, Parabola, Catenary, and Sandia configurations than with modified parabola or straight types. The increase in solidity with increasing number of blades raised the starting torque and improved the dynamic stability during the initial operational speed of Darrieus wind turbine. Additionally, these torque results represent basic data for fluid-structure interaction (FSI) simulation of the steady-dynamic operation of the turbine.

식품 중 다환방향족탄화수소 분석법 연구 (A study on analytical methods for polycyclic aromatic hydrocarbons in foods)

  • 김용연;신한승
    • 식품과학과 산업
    • /
    • 제55권1호
    • /
    • pp.45-57
    • /
    • 2022
  • This study was proceeded the analytical methods using various analytical instruments for polycyclic aromatic hydrocarbons (PAHs) in food products. Various analytical methods were developed to determine levels of PAHs including benzo[a]pyrene, benzo[a]anthracene, benzo[b]fluoranthene, and chrysene formed in various food products using gas chromatography-mass spectrometry (GC-MS), enzyme-linked immunosorbent assay (ELISA) and raman spectroscopy. Recently, the rapid on-site response for the detection of hazardous substances in food aims to develop an onsite rapid detection of a simplified technical analysis method to reduce the time and cost required for analysis of PAHs. Current PAHs detection methods have been reviewed along with new raman spectroscopy analytical method.