• Title/Summary/Keyword: FRTU

Search Result 35, Processing Time 0.022 seconds

A Voltage Control Method based on Constants of Four Terminals Network Modeling of Distribution Networks

  • Yang, Xia;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kim, Tae-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.354-362
    • /
    • 2008
  • In this paper, a new algorithm of optimal voltage control is proposed for the Distribution Automation System (DAS) based on constants of four terminal network modeling. In the proposed method, the voltage profiles along feeders are estimated from the measurement of the current and power factor by a Feeder Remote Terminal Unit (FRTU) installed at each node. Whenever the voltage profile violates the restriction, the voltage control strategy is applied to keep the voltage levels along the feeders within the pre-specified range through the modification and coordination of the transformer under-load tap changers (ULTC), step voltage regulator (SVR), as well as shunt condenser. In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with 11 nodes.

The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System (분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

The Self-Fault Determination and Restoration Methodology based on the Ethernet Communication (이더넷 통신기반의 자율적 고장 판단 및 복구 방법론 연구)

  • Ko, Yun-Seok;Lee, Seo-Han;Choi, Hyun-Chul;Shin, Jae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1674-1680
    • /
    • 2009
  • This paper proposes an autonomous fault determination, fault zone isolation and fault restoration strategy based on the ethernet communication as a new attempt to solve the problem the of the existing central control method. In proposed method, The FRTU(Feeder Remote Terminal Unit)s on the feeder determines autonomously where the faulted zone is by exchanging the voltage and current information with neighbor FRTUs based on the network communication, and then separates the faulted zone in an nil-voltage status to make the protective device to reclose successively. In particular, the minimization of outage time and relational load balancing is archived by each interconnection switch which determines autonomously the load zone to be allocated among those zones after the sound outage zones was separated individually. Finally, to show effectiveness of the proposed fault restoration strategy, the several fault cases are simulated for the test distribution system, and the load balancing index of the proposed solution is compared with all of feasible solutions.

MFTG(Multi Function Tetra Gateway) Platform

  • Sang-Hun Lee;Sei-byuck Kim;Byeong-Kwon Song;Tae-Eui Jeong;Gun-Woong Kim;Jin-Cheol Kim;Young-eok Kim
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.1224-1227
    • /
    • 2008
  • 송변전자동화시스템에서 사용하는 주장치 와 RTU간에는 무선 통신망으로 TRS(Trunked Radio System), CMDA(Code Division Multiple Access) 그리고 에어미디어망을 사용하고 있다. 특히 디지털 TRS기술인 유럽 전자 통신 표준기구인 ETSI에서 개발한 TETRA는 임대망인 CDMA와 에어미디어망과는 달리 비임대망으로 비용적인 장점을 가지고 있다. 본 논문은 송변전자동화시스템에서 주장치 기능을 하는 DNP3.0 주장치 서버와 RTU의 기능을 하는 FRTU간에 TETRA 망을 사용할 수 있도록 MFTG(Multi Function Tetra Gateway) Platform을 구현하였다.

A Study on the Algorithm for the Determination of Fault Section in Bidirectional Distribution Line (양방향 배전선로에서 고장구간 판단 알고리즘 연구)

  • Park, Hak-Yeol;Seo, Dong-Kwen
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.521_523
    • /
    • 2009
  • 최근 고유가에 따른 발전비용 증가와 교토의정서 발휘로 인한 $CO_2$ 저감의무 등 환경보전이라는 사회적 요구와 맞물려 새로운 신재생에너지 분야에 관심이 고조되고 있는 실정이다. 이러한 신재생에너지로 대표되는 풍력, 태양광, 연료전지 등을 이용하는 발전방식은 저용량의 발전으로 대규모 집중형 전원이 아니 전력 수요지 근방에서 설치되는 비교적 작은 규모의 분산형전원(DG;Distribution Generator)으로 배전선로에 직접 연계됨에 따라 배전계통에도 큰 변화가 일고 있다. 분산전원(DG)이 배전계통에 연계됨에 따라 전압변동에 따른 전압조정, 고조파 계통유입에 따른 전기품질, 계통고장시의 분산전원의 단독운전 방지, 고장전류의 분산에 따른 선로의 보호협조 등 다양한 새로운 문제점이 대두되고 있고 이를 해결하기 위해 연구개발 및 신기자재개발 등이 활발히 진행되고 있다. 현재 배전자동화시스템에 적용되고 있는 고장검출 알고리즘은 단방향으로 전기를 공급하던 전통적인 배전방식에서 단순 과전류요소에 의해 고장검출하는 알고리즘을 적용하고 있기 때문에 분산전원이 연계된 양방향 전기공급 배전계통에서는 정확하게 고장구간을 검출하기 어렵다. 이로 인해 고장판단 문제점과 보호기기의 오동작 등으로 정확하게 고장구간을 판단하지 못하여 광역정전이 발생되고 고장복구가 장시간 소요되고 있는 실정이다. 본 논문에서는 이를 해소하기 위해 양방향 전기공급 배전계통에서 고장이 발생시 고장점으로 유입되는 고장전류의 파형형태를 분석하여 고장 구간을 판단하는 알고리즘을 소개하고자 한다. 또한 다기능 mFRTU(mFRTUmulti-function Feeder Remote Terminal Unit) 의 고장 구간 판단 알고리즘의 신뢰성을 검증하기 위해 실선로에서 실증시험을 시행하였으며, 그 결과를 분석하여 타당성을 제시하고자 한다.

  • PDF