In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.
In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.
본 논문은 SNMP(Simple Network Management Protocol)기반의 ATM 교환 장비를 CMIP(common management information protocol)기반의 관리망에 연동하기 위한 Q3 Adaptor 기능 중 ATM 연결 관리와 Frame Relay 연동 관리를 소개한다. 본 논문의 ATM연결 관리는 점대점(Point-to-Point Permanent Virtual Connection) PVC(P)로 한정하고, FR 연동 관리는 ATM/FR 연결의 One-to-One PVC로 한정하며 ATM 밀 ATM/FR 연결에 대하여 CMIP Manager, Q3 Adaptor 및 교환 장비의 DB간 불일치 현상을 극복하기 위한 현행화 기능도 소개한다.
저독성 폴리올레핀 절연재료, Sheath재료의 저독성, 연기밀도특성, 연소가스부식성 분석을 하기 위하여 저독성 내화케이블의 성능평가 시험을 수행하였다. 화재 발생시 화염확산 및 유독성가스발생의 주원인으로 피난안전계획에 매우 중요하다. 90년대 후반기부터 연이어 발생한 씨랜드 화재사고와 인천 인현동 라이브클럽등의 동일한 유형을 가진 화재사건을 계기로 국내 내화케이블에 사용되는 재료가 화재시 인명참사에 미치는 영향이 크다는 점이 발견되었다. 본 연구에서는 고체물질에서 발생하는 연기의 특성광학밀도를 ASTM E662를 근거로 하여 실험을 하였다. 전기로의 시스템은 20분동안 밀폐된 챔버내에서 2.5$\pm$0.04w/$\textrm{cm}^2$을 지닌 조사열량을 일정한 상태 하에서 방사를 유지할 수 있도록 하였다. NFR-8과 FR-PVC 연기밀도의 분해 결과에 따라 완전연소에 의한 연기밀도 최대값 NFR-8은 25.2에서 39.6 FR-PVC에서 51.1의 값을 얻을 수 있었다. 비연소 열분해에 의한 연기밀도 최대값 NFR-8은 100.4에서 112.2 FR-PVC는 126.5에서 398.8의 값을 얻을 수 있었다. 또한 시료의 연기밀도 분석결과 PVC가 폴리올핀 시료보다 상당히 많은 양의 CO가 발생되는 반면 $CO_24의 양은 적게 발생하였다.
The permeation of $Ca^{2+}$ ions through the materials such as polyvinyl chloride (PVC) and non-halogenated flame retardant cross linked polyolefin (FR-XLPO) used for CN-CV underground distribution power cable jackets was investigated. The permeation of $Ca^{2+}$ ions was found to increase with the increase of time. The FR-XLPO showed higher permeation of $Ca^{2+}$ ions, by a factor of about two, than the PVC. This was explained by the destruction of structural integrity caused by mixing a large amount of mineral flame retardant such as $Mg(OH)_2$ used to impart non-flame ability to the jacket material.
Permeation of $Ca^{2+}$ ions in PVC and flame-retardant polyolefin (FR) compounds for the sheath of medium voltage underground cables was studied. At $70^{\circ}C$ ion permeation increases fast at times of up to a few tens of hour and then at a relatively slow rate. The first fast increase was attributed to the diffusion of ions in the samples while the second slow increase of ion permeation was attributed to the permeation of $Ca^{2+}$ ions through the samples. It was also found that the diffusivity of $Ca^{2+}$ ions in FR compounds is much higher than that in PVC compounds.
프레임 릴레이망을 백본으로 한 LAN과 LAN 접속으로 형성되는 서비스가 PVC 형태로 제공되고 있다. 이는 향후 ATM 망을 백본으로 한 프레임 릴레이 인터페이스를 제공하기 위해, 다양한 서비스의 접속과 서비스 질을 만족하는 Frame Relay/ATM (FR/ATM) 연동장치가 필요하다. 본 논문에서는 FR/ATM 연동장치에서 프레임 릴레이 트래픽에 대한 성능분석의 모의 실험을 토큰 방식에 근거한 리킷 버킷 알고리즘으로 수행하였다. 다양한 트래픽을 발생시킨 컴퓨터 모의실험에서 프레임 릴레이망으로부터 수신되는 프레임이 정상적으로 처리될 비율, 프레임이 정상적으로 처리되나 버려질 수 있는 비율 및 충분하지 못한 토큰으로 인하여 프레임이 버려질 수 있는 비율이 다양하게 제시되었다.
프레임 릴레이망을 백본으로 한 LAN과 LAN접속으로 형성되는 기업통신망이 현재 활발히 전개되면서 인터넷을 통한 광고, 전자거래가 중요한 서비스로 진행되고 있다. 국내의 프레임 릴레이 서비스 현황을 살펴보면 KT, 데이콤, 일부기업등에서 프레임 릴레이 교환기를 수입하여 주고객인 기업에 서비스를 제공하고 있다. 이들은 사용자 요구에 의해 주로 LAN과 LAN에 접속된 라우터 등의 종단 시스템간 PVC(영구가상회선: Permanant Virtual Circuit)접속을 통하여 다양한 서비스를 제공하면서 독자적인 기업통신체계를 구축하고 있는 실정이다. 이와같이 사용자 요구로 PVC등록시 프레임 릴레이망과 LAN을 연결하는 링크의 QoS(서비스 질: Quality of Service), 트래픽 파라메터는 수동적으로 설정된다. 현재 국내에서는 프레임 릴레이 교환기 개발은 전무하고 단지 그들을 수입하여 운용하는 수준이며 향후 ATM(비동기 전달모드: Asynchronous Transfer Mode)망의 중요 서비스 연동이 될 프레임 릴레이 기술은 심도있게 연구되고 있다. 향후 고속통신을 제공하는 백본망은 기존의 프레임 릴레이망과 ATM망이 공존할 추세이며 점진적으로 프레임 릴레이망은 사라질 것이다. 이때 ATM 망이 기존의 프레임 릴레이망을 백본으로 한 기업통신망 수용시 원할한 서비스 제공을 위해서는 프레임 릴레이망을 백본으로 채택한 기존의 기업통신망을 ATM망에서 수용시 야기되는 문제점의 제시와 이의 해결은 매우 중요하다고 생각된다. FR/ATM(Frame Relay/ATM)연동시 기업통신망 입장에서는 PVC뿐만 아니라 SVC(교환가상회선: Switched Virtual Circuit)호처리가 수용되어야 한다. 이와같이 PVC와 SVC 수용으로 기업통신망은 통신망의 구성 및 관리가 복잡, 다양해지며, 또 그 기업은 관련된 다양하고 수많은 고객과 접속될 수 있어야 한다. 이때 ATM망을 백본으로 한 공중망이 관련 기업의 사설 정보를 관리하도록 한다는 것은 그 서비스의 이용자에게 보안문제를 제기함은 물론 서비스 이용자가 자신의 망에서 동작하는 여러 서비스를 고객 스스로가 관리하는 것이 바람직하다. CNN(고객망관리 : Customer Network Management)은 이러한 고객에 의한 통신망, 공중망에 대한 부분적 관리 및 서비스에 대한 관리가 이루어 질수 있도록 수행하는 기능이다. 본 논문에서는 ATM망이나 프레임 릴레이망과 ATM 망이 공존시 기업통신망관점에서 야기되는 문제점의 제시와 이의 해결 방안을 살펴보았다. 우선 FR/ATM 연동에서 PVC설정뿐만 아니라 SVC 설정 방법의 연구, 이때 고려된 QoS,트래픽 처리과정을 살펴보았다. 또한 망관리 입장에서 기업통신망 관리자와 ATM망 관리자와의 온-라인 서비스를 제공하기 위해서는 변화된 통신망 차원서의 확장된 Managed Object(MO)를 근간으로한 체계적인 CNN-NMS(CNM-Network management System)연동을 살펴본후 결론에서는 추후 계속연구 및 조사 되어야 할 항목을 기업통신망 입장에서 서술하여 보았다.
In general, the insulation and protective sheaths on electrical conductors are made of combustible substances like PVC, natural or synthetic rubbers, and other organic or synthetic materials. When an electrical fire starts due to overheating of conductors/joints or sparking/arcing, the first thing to ignite is usually the insulation on the cables. When the insulation bums, the produced fumes are very toxic. To solve the problem, we have surely need the fire resistance cable that doesn't bum in a high temperature and emit toxic fume for operating a disaster prevention installation. In this paper, we have simulated the thermal analysis for the fire resistance cable according to the values of current in a overload and a short, and the values of outside flame with the fire resistance cable of the L's company product(600 V, FR-8 : Four Core) using the finite element method(Flux2D).
인터넷과 멀티미디어 상품이 일반화되면서, 멀티미디어 컨텐트웨어 상품 평가에 대한 필요성이 대두되고 있다. 1993년 이후 등장한 인터액티브 멀티미디어 상품은 소비자들에게 전혀 새로운 차원의 체험을 제공하여 급속히 그 영역 및 범위를 확장하고 있는 실정이다. 이렇듯 급속히 팽창하고 있는 인터액티브 멀티미디어 시장에서 경쟁력 있는 상품을 제작하기 위해서는 일단 체계적으로 멀티미디어 상품을 분석할 수 있는 평가시스템의 구축이 필요하다. 또한 이를 바탕으로 디자인 요소 및 프로세스의 개발이 필요 되어진다고 볼 수 있다. 본 연구는 이러한 작업과정의 일환으로, 우송산업대학교, 한국과학기술원, 그리고 삼성 ids와 공동으로 1997년 8월에서 1998년 1월까지 진행되었다. 본 연구는 특히 멀티미디어 상품에서 경험되어지는 새로운 차원의 체험이 사용자 만족에 미치는 영향에 중점을 두어 사용자 만족요소를‘합목적성’, ‘사용성’, ‘문화성’으로 분류하고, ‘문화성’만족 요소 추출을 감성공학적 기법을 도입하여 시도하였다. 연구결과 일반적인 소비자들에게는 4개의 문화성 만족 요소가 있는 것으로 파악되었고, 이 요소는(정보 습득과정에서의) 사용자 가치, (정보 습득과정에서의) 구성의 완성도,(정보 습득과정에서의) 시각적 완성도, 그리고 (정보 습득과정에서의) 시대성 등이다. 본 연구에서는 또한 문화성 만족 요소를 바탕으로 하는 문화성 평가시스템도 구축하여 7개 기업 웹사이트를 대상으로 사례연구를 실시하여 웹 디자인의 특징적 요소와 사용자 문화성 만족과의 상관관계의 파악을 시도하였다.할 수 있다.기업통신망 입장에서는 PVC뿐만 아니라 SVC(교환가상회선: Switched Virtual Circuit)호처리가 수용되어야 한다. 이와같이 PVC와 SVC 수용으로 기업통신망은 통신망의 구성 및 관리가 복잡, 다양해지며, 또 그 기업은 관련된 다양하고 수많은 고객과 접속될 수 있어야 한다. 이때 ATM망을 백본으로 한 공중망이 관련 기업의 사설 정보를 관리하도록 한다는 것은 그 서비스의 이용자에게 보안문제를 제기함은 물론 서비스 이용자가 자신의 망에서 동작하는 여러 서비스를 고객 스스로가 관리하는 것이 바람직하다. CNN(고객망관리 : Customer Network Management)은 이러한 고객에 의한 통신망, 공중망에 대한 부분적 관리 및 서비스에 대한 관리가 이루어 질수 있도록 수행하는 기능이다. 본 논문에서는 ATM망이나 프레임 릴레이망과 ATM 망이 공존시 기업통신망관점에서 야기되는 문제점의 제시와 이의 해결 방안을 살펴보았다. 우선 FR/ATM 연동에서 PVC설정뿐만 아니라 SVC 설정 방법의 연구, 이때 고려된 QoS,트래픽 처리과정을 살펴보았다. 또한 망관리 입장에서 기업통신망 관리자와 ATM망 관리자와의 온-라인 서비스를 제공하기 위해서는 변화된 통신망 차원서의 확장된 Managed Object(MO)를 근간으로한 체계적인 CNN-NMS(CNM-Network management System)연동을 살펴본후 결론에서는 추후 계속연구 및 조사 되어야 할 항목을 기업통신망 입장에서 서술하여 보았다.관(關)한 모든 것을 연구(硏究)해 보아야 한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.