• Title/Summary/Keyword: FOV(field of view)

Search Result 215, Processing Time 0.026 seconds

Design and Verification of 3D Digital Image Correlation Systems for Measurement of Large Object Displacement Using Stereo Camera (대면적 대상물 변위계측을 위한 스테레오 카메라 3차원 DIC 시스템 기초설계 및 검증에 관한 연구)

  • Ko, Younghun;Seo, Seunghwan;Lim, Hyunsung;Jin, Tailie;Chung, Moonkyung
    • Explosives and Blasting
    • /
    • v.38 no.2
    • /
    • pp.1-12
    • /
    • 2020
  • Digital Image Correlation is a well-established method for displacements, strains and shape measurements of engineering objects. Stereo-camera 3D Digital Image Correlation (3D-DIC) systems have been developed to match the specific requirements for measurements posed by material and mechanical industries. Although DIC method provides the capabilities of scaling a field-of-view(FOV), dimensions of Geotechnical structure objects in many cases are too big to be measured with DIC based on a single camera pair. It can be the most important issue with applying 3D DIC to the measurement of Geotechnical structures. In this paper, We were present stereo vision conditions in a 3D DIC system that can be measured for large FOV(30×20m) and high precisions(z-displacement 0.5mm) of the ground objects with Stereo-camera DIC systems.

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Study on the Coverage by COMS OCI FOV

  • Kang C. H.;Seo S. B.;Lim H. S.;Park D. J.;Ahn S. I.;Koo I. H.;Hyun D. H.;Yang H. M.;Choi H. J.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.336-339
    • /
    • 2004
  • Communication, Ocean and Meteorological Satellite (COMS) has been developed by Korean Aerospace Research Institute (KARI) since 2003. Ocean Color Imager (OCI) is the one of COMS payloads, which will monitor the marine environment around Korean peninsula routinely with the intermediate resolution. But considering COMS is to be located in the geostationary orbit, required geographical coverage is not positioned in the nadir direction of COMS but in specific location with horizontal and vertical offsets from the nadir. In this study, coverage by OCI Field Of View (FOV) is analyzed. First of all, OCI is modeled as the sensor which is a $2,500{\times}2,500$ sized 2-D CCD and the pixel resolution is about 500m. And then, OCI is simulated to be controlled to target the required coverage accurately. As a result of it, coverage by OCI FOV is determined. Finally, all coverages by OCI FOV are mapped.

  • PDF

Wide FOV Panorama Image Acquisition Method (광각 파노라마 영상획득 방법)

  • Kim, Soon-Cheol;Yi, Soo-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2117-2122
    • /
    • 2015
  • Wide FOV(Field-of-View) is required to contain much more visual information in a single image. The wide FOV imaging system has many industrial applications such as surveillance, security, tele-conference, and mobile robots. In order to obtain a wide FOV panorama image, an imaging system with hyperbolic cylinder mirror is proposed in this paper. Because the horizontal FOV is more important than the vertical FOV in general, a hyperbolic cylinder mirror is designed in this paper, that has a hyperbolic curve in the horizontal surface and is the same as a planar mirror in the vertical axis. Imaging model of the proposed imaging system is presented by ray tracing method and the hyperbolic cylinder mirror is implemented. The imaging performance of wide FOV is verified by experiments in this paper. This imaging system is cost-effective and is possible to acquire a wide panorama image having 210 degree horizontal FOV in real-time without an extra image processing.

Psychophysiological Effects of Navigation in a Virtual Reality (가상현실에서의 운행이 인체에 미치는 영향에 대한 심리생리학적 연구)

  • 김영윤;김현주;정명숙;이영혁;문성재;진창배;고희동;박병관;박광석
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.242-248
    • /
    • 2000
  • 본 연구에서는 가상현실에서 simulator factor [FOV (field of view)와 운행속도, frame rate의 fluctuation]를 변화시키면서 사용자들의 시지각 과제수행도, 생리신호의 변화를 관찰하였고, 가상현실 경험 전·후에 실시한 설문지 조사를 통해 심리적 영향도 알아보았다. 1) 가상현실 운행시 눈깜박임이감소하고 Pz, O1, O2 영역의 알파파가 줄어들며 텔타파가 늘어나는 생리적 변화가 나타났다. 2) 특히 가상현실에서 멀미를 보고했을때 심박률, 피부전도도가 증가하고 피부온도가 감소하는 것으로 나타났다. 멀미 보고시 나타난 변화는 교감신경계의 활동성이 증가하는 방향과 일치하였다. 3) 빠른 운행속도가 느린 운행속도보다 높은 말초혈류량 최대-최소차이값을 나타냈고, 넓은 FOV가 좁은 FOV보다 높은 심박률을 나타냈다. 좁은 화면 보다 넓은 화면 조건에서 Cz, Pz 영역의 알파파는 더 낮게 나타났고 텔타파는 더 높게 나타났다. frame rate의 fluctuation이 없을 때에 비해 있을때 더 높은 피부전도도를 보여주었다. 4) 가상현실 평가설문지 분석결과 신체적 불편감은 좁은 FOV·느린 운행속도 조건에서 가장 적은 불편감을 나타냈다. 과제수행 곤란도는 느린 운행속도에서 가장 적게 나타났고 과제수행 적중률은 느린 운행속도에서 가장 높게 나타났다. 생리신호, 과제수행 적중률, 설문지 분석결과는 좁은 FOV·느린 운행속도의 가상환경이 가장 멀미에 덜 민감하고 과제수행하기에 가장 용이한 것으로 나타났다.

  • PDF

How to Choose and Use the CBCT (임상가를 위한 특집 1 - CBCT의 선택과 처방)

  • An, Chang-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.132-138
    • /
    • 2014
  • The emergence of Cone Beam Computed Tomography(CBCT) in the late 1990s represented an innovative advancement in the field of dental and maxillofacial radiology because it greatly reduced the radiation exposure to patients and offered 3D images easily. The 3D information generated by this technique brings the potential of improved diagnosis and treatment planning for a wide range of clinical applications in dentistry. The use of CBCT includes diagnosis and surgical assessment of the orofacial hard tissue lesions, dental implant treatment planning and postoperative evaluation, TMJ assessment, diagnosis of craniofacial fracture, orthodontics, endodontics, and so on. All CBCT examinations should be justified on an individualized needs. The clinical benefits to the patient for each CBCT scan must outweigh the potential risks associated with exposure to ionizing radiation. CBCT scans should be taken with initially obtained medical and dental histories of patients and a close clinical examination. CBCT should be considered as an imaging alternative of other conventional radiography in cases where the anatomical structures of interest may not be seen. The smallest possible field of view(FOV) and the lowest setting of tube current and scan time should be chosen, and the entire images scanned should be interpreted by a qualified expert.

On the Optical Characteristics of Solar X-Ray Telescopes: Possible Relation between Vignetting Effect and Mirror Scattering

  • Shin, Jun-Ho;Sakurai, Takashi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • Since early 90's, the solar X-ray telescopes such as Yohkoh SXT and Hinode XRT have observed coronal magnetic structures on the Sun's surface in the range of about $40'{\times}40'$ field-of-view (FOV) covering the full solar disk. Thus it has been stressed by the scientists that the optical structure of solar telescopes should be designed with care for improving the uniformity over a wide FOV. There would be, however, no unique solution in designing the optical system of a telescope for overcoming perfectly the problem of off-axis response variation. As a consequence, the correction of optical imperfectness of telescopes has become an important calibration step that should be performed beforehand when the observed images are to be used for photometric purposes. In particular, a special care should be taken when performing the temperature analysis with thin and thick filters for flaring activities observed at the periphery of the full FOV. From the analyses of both pre-launch calibration and in-flight observation data, the optical characteristics for describing the performance of solar X-ray telescopes, especially in view of their energy dependence, will be introduced and discussed in our presentation.

  • PDF

The Off-Axis Properties of Solar X-Ray Telescopes: I. Evaluation of the Vignetting Effect

  • Shin, Jun-Ho;Sakurai, Takashi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • The solar X-ray telescopes, the Yohkoh SXT and the Hinode XRT, have observed for a couple of decades a variety of coronal structures in the range of wide field-of-view (FOV) covering the full solar disk. It has been emphasized that the optical structure of solar telescopes should be designed with care for improving the uniformity over the full FOV. The vignetting effect is one of the important optical characteristics for describing the performance of a telescope, which reflects the ability of collecting the incoming light at different locations and different photon energies. The correction of this vignetting effect would be an important calibration step that should be performed in advance, especially when the observed images are to be used for photometric purposes. Since the vignetting effect of solar X-ray telescopes shows wavelength dependence, a special care should be taken when, for example, performing the temperature analyses with thin and thick filters for flaring activities observed at the periphery of the full FOV. The results of analysis of pre-launch calibration data for the evaluation of vignetting effect will be introduced in detail.

  • PDF

Spherical arrangement of biomimetic polymer photonic structures (자연모사를 통한 미세 고분자 포토닉 구조의 구면배열에 관한 연구)

  • Jeong, Ki-Hun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.403-404
    • /
    • 2007
  • Compound eyes in nature present intriguing topics in physiological optics due to their unique optical scheme for imaging. For example, a bee's eye has thousands of integrated photonic units called ommatidia spherically arranged along a curvilinear surface so that each unit points in a different direction. The omni-directionally arranged ommatidium collects incident light with a narrow range of angular acceptance and independently contributes to the capability of wide field-of-view (FOV) detection. Artificial implementation of compound eyes has attracted a great deal of research interest because the wide FOV exhibits a huge potential for medical, industrial, and military applications. So far, imaging with a FOV over $90^{\circ}$ has been achieved only with fisheye lenses which rely on bulky and expensive multiple lenses and require stringent alignment. In this talk, we will discuss about the spherical 3D arrangement of the photonic structures of biologically inspired artificial compound eyes in a small form-factor to have and the functional and anatomical similiarity with natural compound eyes.

  • PDF

A Guidance Law with a Switching Logic for Maintaining Seeker's Lock-on for Stationary Targets

  • Sang, Dae-Kyu;Ryoo, Chang-Kyung;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.87-97
    • /
    • 2008
  • Modem anti-ship missiles employ complex and sophisticated guidance laws to hit the target and enhance their survivability by executing additional maneuvers. However, such maneuvers may cause the target to move out of the missile seeker's Field-Of-View (FOV). Maintaining seeker lock-on during an engagement is a critical factor for missile guidance. In this paper, a guidance law switching logic that maintains seeker lock-on and a simple guidance law that keeps the target look angle of the seeker constant is proposed. The proposed method can be used for the terminal homing phase, and can be switched from any kind of guidance laws if a proper switching condition is satisfied. The minimum and maximum flight time calculation method in consideration of the missile maneuver limit and the FOV of the seeker is also provided.