• Title/Summary/Keyword: FLUKA 전산 모사

Search Result 2, Processing Time 0.016 seconds

A Study on the Feasibility of Lead(II) Iodide and Gd2O2S:Tb Overlapping Sensors in Gamma Source Conditions using FLUKA Simulation (FLUKA 전산 모사를 통한 감마선원 조건에서의 요오드화납(II)과 Gd2O2S:Tb가 결합된 센서의 적용가능성 연구)

  • Yang, Seung-Woo;Park, Yoon-Hee;Park, Ji-Koon;Heo, Ye-Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.381-386
    • /
    • 2022
  • Non-Destruction Test (NDT) is a method to check internal defects without destroying the product. Among them, radiographic testing (RT) uses high-energy radiation, so it is very important to prevent radiation exposure of workers. Therefore, in this study, in this study, a radiation sensor structure that improves radiation detection performance compared to the existing PbI2 and can immediately detect accidents in RT was presented. For evaluation, the conversion efficiency was analyzed in the gamma ray source through FLUKA simulation. PbI2 with overlapping Gd2O2S:Tb presented in this study showed a higher radiation sensitivity from 1.22 to 3.22 times than that of non-overlapping PbI2. This indicates that the presented sensor is suitable for use as a radiation sensor for source detection in RT.

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.