• Title/Summary/Keyword: FLATNESS

Search Result 616, Processing Time 0.028 seconds

Design and Implementation of Dielectric Resonator Bandpass Filters with Various Time-Delay (다양한 시간지연을 갖는 유전체 공진기 대역통과 필터의 구현)

  • Choi, U-Sung;Park, Noh-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2397-2402
    • /
    • 2010
  • Dielectric resonator bandpass filters with various time-delay at 800MHz were designed and fabricated in this paper. from the results of this study. first of all, good response. characteristics were measured for all cases. The insertion loss was below 2dB and flatness for ripple was below 0.2dB, whereas return loss was over 20dB, respectively. The measured delay time of the fabricated prototype were 6ns, 12ns and 200s, respectively and the flatness characteristics did not exceeding Ins for all cases. Furthermore, 2~4ns of flatness were measured for 2-hole dielectric block and other dielectric resonator filters with various delay time by combination of each prototypes filters were also implemented.

Heart Murmur Detection Algorithm based on Spectral Flatness (주파수 평탄도에 기반한 심잡음 검출 알고리즘)

  • Lee, Yunjung;Lee, Gihyoun;Na, Sung Dae;Seong, Ki Woong;Cho, Jin Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.3
    • /
    • pp.557-566
    • /
    • 2016
  • Heart sounds generated by the beating heart and blood flow reflect the turbulence created when the heart valves snap shut. Cardiac diagnosis is typically started by an auscultation using a stethoscope, from which a medical doctor, depending on his hearing capabilities and training, listens and interprets the acoustic signal. This method of diagnostic is uncertain, mostly due to the fact that human ear loses the acoustic frequency sensitivity through the years. Even though an auscultation has some weaknesses like uncertainty, it is considered as a primary tool due to its simplicity. In this paper, heart murmur detection algorithm is proposed using time and frequency characteristics of heart sound. The propose heart murmur detection method adapted conventional primary heart sound detection method in time domain and modified spectral flatness method in frequency domain for detecting heart murmurs. From experimental results, it is confirmed that the proposed algorithm detect the heart murmurs efficiently.

Effects of Varying Contact back-up Roll on the strip flatness (VCR 롤이 판평판도에 미치는 영향)

  • Chen, Xianlin;Zhang, Jie;Yang, Quan;Zhang, Quingdong
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.144-147
    • /
    • 1998
  • VCR is a back-up roll with a special contour which leads to the length of the contact line between back-up roll and work becones self adjustable in accordance with the width of the strip. The simulation of a finite element model and the on-line test at production mill demonstrate that the VCR roll may keep the crown of the roll gap relatively stable, and at same time, permit the rolling pressure to be adjusted over a wider range, and increase the effect of work roll bending on the roll gap. The VCR rolls have been successfully used at the first stands of two largest cold rolling mills in China, and on-line test has been done at a wide hot strip finishing train. The use of VCR roll has created favorable conditions for subsequent rolling passes and the achievement of better flatness quality.

  • PDF

Voice Activity Detection Based on Real-Time Discriminative Weight Training (실시간 변별적 가중치 학습에 기반한 음성 검출기)

  • Chang, Sang-Ick;Jo, Q-Haing;Chang, Joon-Hyuk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.100-106
    • /
    • 2008
  • In this paper we apply a discriminative weight training employing power spectral flatness measure (PSFM) to a statistical model-based voice activity detection (VAD) in various noise environments. In our approach, the VAD decision rule is expressed as the geometric mean of optimally weighted likelihood ratio test (LRT) based on a minimum classification error (MCE) method which is different from the previous works in th at different weights are assigned to each frequency bin and noise environments depending on PSFM. According to the experimental results, the proposed approach is found to be effective for the statistical model-based VAD using the LRT.

The Effect of Pyrazine on TMAH:IPA Single-crystal Silicon Anisotropic Etching Properties

  • Gwiy-Sang Chung;Tae-Song Kim
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.21-25
    • /
    • 2001
  • This paper presents the effect of pyrazine on tetramethylammonium hydroxide (TMAH):isopropyl alcohol (IPA) single-crystal silicon anisotropic etching properties. With the addition of IPA to TMAH solutions, etching characteristics are exhibited an improvement in flatness on the etching front and a reduction in undercutting, but the etch rate on (100) silicon is decreased. The (100) silicon etch rate is improved by the addition of pyrazine. An etch rate on (100) silicon of 0.8 ${\mu}{\textrm}{m}$/min, which is faster by 13% than a 20 wt.% solution of pure TMAH, is obtained using 20 wt.% TMAH: 0.5 g/100 ml pyrazine solutions, but the etch rate on (100) silicon is decreased when more pyrazine is added. With the addition of pyrazine to a 25 wt.% TMAH solution, variations in flatness on the etching front are not observed and the undercutting ratio is reduced by 30~50%. These results indicate that anisotropic etching technology using TMAH:IPA:pyrazine solutions provides a powerful and versatile method for realizing of microelectromechanical systems.

  • PDF

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.

Case Study on Treating Acne Scar Using Hani-maehwa Laser (하니매화레이저를 이용한 여드름 흉터 치료 1례)

  • Lee, Deuk-Joo;Kim, Chul-Yun;Kwon, Kang;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.2
    • /
    • pp.106-111
    • /
    • 2016
  • Objective : The aim of this study is to report the effect of Hani-maehwa laser(fractional mode) treatment on acne scar. Methods : The patient with atrophic facial acne scars was treated with 5 sessions of laser therapy at 4-week intervals. The therapeutic response to treatment was assessed at 3 months after last laser session. The treatment effect was evaluated by standardized photography, anti aging, skin brightness and flatness. That was measured by micro fluorescence measurement camera(ECO SKIN, Cuvitz Inc.) in 16(left zygoma) and 26(right zygoma) spot. And side effects were also checked. Results : Atrophic facial acne scars have improved markedly. Anti aging, skin brightness and flatness were improved. Especially anti aging and flatness were noticeably improved. Adverse effects were not reported.Conclusions : Korean medicine cautery method applies to high level laser(CO2 Hani-maehwa laser). These are different designs but same principle. It can be considered that laser therapy is effective method for treating acne scars.

Effects of Insert Materials of Retaining Ring on Polishing Finish in Oxide CMP (산화막 CMP에서 리테이닝 링의 인서트 재질이 연마정밀도에 미치는 영향)

  • Park, Ki-Won;Park, Dong-Sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.44-50
    • /
    • 2019
  • CMP is the most critical process in the manufacture of silicon wafers, and the use of retaining rings, which are consumable parts used in CMP equipment, is increasingly important. Since the retaining ring is made of plastic, it is not only weak in strength but also has the problem of taking a long time for the flattening operation of the ring itself performed before the CMP process, and of the imbalance of force due to bolt tightening causing uneven wear. In order to solve this problem, the retaining ring and the insert ring are integrally used, and the flatness of the retaining ring may be affected depending on the material of the insert ring. Also, the residual stress generated in the manufacturing process of the insert ring may cause distortion of the ring, which may adversely affect the precision polishing. In this study, when the insert ring is made of Zn or STS304, the thickness variation and the flatness of the retaining ring are compared and, finally, the material removal rate is analyzed by polishing the wafer by the oxide CMP process. Through these experiments, the effects of the insert ring material on the polishing accuracy of the wafers were investigated.

Analysis of Door Height Difference and Door Flatness Difference of Built-in Side-by-Side Refrigerator Using Cabinet-Door Integrated Model (캐비닛-도어 통합모델을 이용한 빌트인 양문형 냉장고의 도어 상하단차와 앞뒤단차 해석)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.76-83
    • /
    • 2018
  • A cabinet-door integrated finite element model was constructed for a built-in side-by-side refrigerator with an ice dispenser, and its deformation was analyzed using the ANSYS finite element software. As loads, the food load needed to fill in the cabinet and doors and the thermal load occurring during normal operation conditions were taken into consideration. The door height difference (DHD) and door flatness difference (DFD) between the two doors of the freezing and refrigerating compartments were derived. The DHD and DFD under the assembled condition without applied loads satisfied the acceptance criteria specified by the refrigerator manufacturer. It appeared that the food load increases the DFD slightly. The thermal load tends to increase the differences because of the thermal deformation, especially the DFD, of the cabinet and doors.

Image enhancement in ultrasound passive cavitation imaging using centroid and flatness of received channel data (수신 채널 신호의 무게중심과 평탄도를 이용한 초음파 수동 공동 영상의 화질 개선)

  • Jeong, Mok Kun;Kwon, Sung Jae;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.450-458
    • /
    • 2019
  • Passive cavitation imaging method is used to observe the ultrasonic waves generated when a group of bubbles collapses. A problem with passive cavitation imaging is a low resolution and large side lobe levels. Since ultrasound signals generated by passive cavitation take the form of a pulse, the amplitude distribution of signals received across the receive channels varies depending on the direction of incidence. Both the centroid and flatness were calculated to determine weights at imaging points in order to discriminate between the main and side lobe signals from the signal amplitude distribution of the received channel data and to reduce the side lobe levels. The centroid quantifies how the channel data are distributed across the receive channel, and the flatness measures the variance of the channel data. We applied the centroid weight and the flatness to the passive cavitation image constructed using the delay-and-sum focusing and minimum variance beamforming methods to improve the image quality. Using computer simulation and experiment, we show that the application of weighting in delay-and-sum and minimum variance beamforming reduces side lobe levels.