• 제목/요약/키워드: FFT signal Analyzer

검색결과 23건 처리시간 0.026초

FFT를 이용한 연속초음파 도플러 장치에 관한 연구 (A study on the development of CW(Continuous-Wave) Doppler System using FFT)

  • 이대형;강충신;박세현;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

음향 인텐시티의 누설오차 개선에 관한 기초적 연구 (A Basic Study on the Improvement of Leakage Error of the Acoustic Intensity)

  • 정의봉;정호경;안세진;윤상돈
    • 한국음향학회지
    • /
    • 제22권5호
    • /
    • pp.345-350
    • /
    • 2003
  • 음향 인텐시티는 근접한 두 개의 마이크로폰으로부터 얻어지는 음압의 크로스스펙트럼으로부터 얻어진다. 크로스스펙트럼은 이산 푸리에 변환에 의해 얻어지는데 이는 기록시간과 신호의 주기가 일반적으로 일치하지 않기 때문에 누설오차의 발생을 피할 수 없다. 그러므로 기존의 FFT 해석기로부터 얻어지는 음향 인텐시티는 왜곡된 값을 보여준다. 본 논문에서는 단일주파수를 가지는 조화 신호에 누설오차가 발생한 경우 푸리에 변환된 데이터를 규정한다. 또한 왜곡된 데이터로부터 누설오차의 영향을 제거하는 방법을 제안한다. 제안한 방법의 타당성을 보이기 위해 몇 가지 수치해석 예를 보인다.

회전체 진동 데이터의 AC/DC 성분 데이터 획득 및 분석 장치 (An Acquisition and Analysis Equipment of Dynamic/Static Data on a Rotating Vibration)

  • 이정석;유등열;이철
    • 디지털산업정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.127-137
    • /
    • 2009
  • This paper is proposed that in-output Digital module is acquired a vibration signal of a rotating machinery by Data Acquisition System. The module is designed to get ride of nose through low pass filter on the vibration signal from sensors and set the gain value for being able to sampling AC to DC, and also the sampled data by sampler and the conversed data by DIP/FPGA is supplied to the analyzer for analysis at a software tool. The DIP(Digital Signal Processor) of the Digital input/output Board makes Average voltage, Peak to Peak voltage, RMS(Root Mean Square) and Gap voltage, also FFT(Fast Fourier Transform) for rotating vibration diagnosis.

자동차용 CD/DVD 데크의 진동 저감 및 성능 향상에 관한 연구 (A Study on the Vibration Reduction and Performance Improvement of the CD/DVD is used from the Vehicle)

  • 박영필;정두한;정진태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.799-804
    • /
    • 2004
  • Dynamic characteristic of CD/DVD deck for vehicle is analyzed in this paper. Generally CD/DVD deck for vehicle is used from inferior environment with the vibration of the vehicle and shock of outside and so on. Therefore it must have the structure which is stabilized from the vibration to prevent read error. For this purpose, vibration characteristic of the deck for vehicle should be identified. To analyze characteristic of the deck system, we perform the signal analysis and modal testing using the FFT analyzer. Also we change the design factor degrading the performance of the deck system and verify the efficiency improvement using the acceleration measurement occurring to the sound discontinuation.

  • PDF

스토케스틱 방법에 의한 공작기계의 안정성 해석

  • 김광준
    • 한국정밀공학회지
    • /
    • 제1권1호
    • /
    • pp.34-49
    • /
    • 1984
  • The stability of machine tool systems is analyzed by considering the machining process as a stochastic process without decomposing into machine tool structural dynamics and cutting processes. In doing so the time series analysis technique developed by Wu and Pandit is applied systematically to the relative vibration between cutting tool and work- piece measured under actual working conditions. Various characteristic properties derived from the fitted ARMA(Autoregressive Moving Average) Models and those from raw data directly are investigated in relation with the system stability. Both damping ratio and absolute value of the characteristic roots of the AR part of the most significant dynamic mode are preferred as stability indicating factors to the other pro-perties such as theoretical variance .gamma. (o) or absolute power of the most dominant dynamic mode. Maximum aplitude during a certain interval and variance estimated from raw data are shown to be very sensi- tive to the type of the signal and the location of measurement point although they can be obtained rather easily. The relative vibration signal is also analyzed by FFT(Fast Fourier Transform) Analyzer for the purpose of comparison with the spectrums derived from the fitted ARMA models.

  • PDF

단일 주파수를 갖는 음향 인텐시티의 누설오차 개선 (Leakage Error Improvement of the Intensity with a single freqency)

  • 정의봉;안세진;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1156-1161
    • /
    • 2001
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

IEEE 802.16e 기반 OFDMA 물리층 분석 알고리즘 연구 (Develop physical layer analysis algorithm for OFDMA signal based IEEE 802.16e)

  • 장민기
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.342-349
    • /
    • 2019
  • 802.16e에 기반한 OFDMA 물리층 분석을 위한 분석 장비 개발에 있어, 하드웨어 구성 및 신호 특성 분석 알고리즘에 관한 방법론에 대해 기술하고 구현결과를 분석한다. 최근 디지털 통신 신호의 발달과 함께 이를 분석하는 계측기의 신호분석에 대한 수요도 빠르게 증가하고 있다. 신호분석에 대한 수요의 급속한 증가에 따라 광대역 디지털 신호처리 모듈을 이용한 광대역통신 신호 특성 분석이 가능한 신호분석 장비를 개발하는 것이 필요하다. 본 논문에서는 광대역통신 신호 특성 분석이 가능한 장비를 고안하기 위하여 첫째, OFDMA의 기본이론을 학습하고, 둘째 OFDMA 송/수신기 구조를 검토하였으며 셋째, 광대역 디지타이져를 구현하였다. 광대역 통신기법 중 OFDMA에 기반한 Wimax 신호분석 알고리즘을 설계하여 I, Q신호를 통한 Wimax 물리층 분석 SW구현을 제안하였다. IF다운 컨버터는 스펙트럼 분석기의 수신 모듈 및 LO발생 모듈을 이용하였으며, I, Q 데이터에 의한 WiMAX 신호분석 알고리즘을 통해 정량적 분석결과를 도출 하였다.

전자파에 노출된 생체두부의 전기생리적 변화의 측정에 관한 연구 (Measurement of electro-physiological changes in the brain exposed to eletromagnetic wave radiation)

  • 이준하;신현진;이상학;유동수;이무영;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제5권2호
    • /
    • pp.35-43
    • /
    • 1994
  • 전자파가 일상생활에서 생체에 많은 영향을 미치는 것으로 알려져 있으나 실제로 그 영향을 정성, 정량적으로 규명하는 것은 용이하지 않다. 본 연구에서는 생체의 전기적 신호를 이용하여 2.45GHz의 전자파에 노출시킨 토끼의 두부에 대한 영향을 측정하는 방법을 검토하였다. 연구결과, 두부모델의 손상정도는 뇌전위의 연속적인 FFT 신호처리에서 뇌활성도 저하를 관찰할 수 있었으며, 특정 주파수와 강도(최소허용전력과 치사전력)에 대한 기준 설정에 필요한 요소를 제시할 수 있었다.

  • PDF

바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발 (Development of PC-based and portable high speed impedance analyzer for biosensor)

  • 김기련;김광년;허승덕;이승훈;최병철;김철한;전계록;정동근
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.

광강도형 광섬유 진동센서를 이용한 진동감지 및 충격위치 측정 (Vibration Sensing and Impact Location Measurement Using Intensity-Based Optical Fiber Vibration Sensor)

  • 양유창;황운봉;박현철;한경섭
    • Composites Research
    • /
    • 제13권5호
    • /
    • pp.1-9
    • /
    • 2000
  • 광강도형 광섬유 진동센서를 이용한 구조물의 진동감지 및 판에서의 충격위치 검출에 관한 연구가 수행되었다. 광섬유 진동센서는 유리 모세관의 내부에 광섬유의 클래딩 부분이 서로 마주보게 하여 제작되며 그 중 한 쪽은 외팔보 형태이다. 진동이 센서에 가해지면 센서 내부의 외팔보가 진동하게 되고 그에 따라 맞은편 광섬유로 전해지는 빛의 강도가 변화하게 된다. 진동감지 실험을 위해 광섬유 진동센서를 복합재료 보의 표면에 부착하고 자유 진동 및 강제 진동에 대한 신호를 취득하였다. 충격 위치 검출에 관한 실험은 아크릴 판에 대하여 알려진 위치에 네 개의 센서를 표면에 부착하고 진동의 도달 시간을 FFT를 이용하여 측정하였다. 충격위치는 이러한 시간차이를 이용하여 계산되어졌다. 광섬유 진동센서는 상용센서인 갭센서와 동일하게 구조물의 진동을 감지하였으며 판에서의 충격위치를 비교적 정확히 측정하였다.

  • PDF