• 제목/요약/키워드: FFP

검색결과 75건 처리시간 0.033초

MICROLENSING BY KUIPER, OORT, AND FREE-FLOATING PLANETS

  • GOULD, ANDREW
    • 천문학회지
    • /
    • 제49권4호
    • /
    • pp.123-126
    • /
    • 2016
  • Microlensing is generally thought to probe planetary systems only out to a few Einstein radii. Microlensing events generated by bound planets beyond about 10 Einstein radii generally do not yield any trace of their hosts, and so would be classified as free floating planets (FFPs). I show that it is already possible, using adaptive optics (AO), to constrain the presence of potential hosts to FFP candidates at separations comparable to the Oort Cloud. With next-generation telescopes, planets at Kuiper-Belt separations can be probed. Next generation telescopes will also permit routine vetting for all FFP candidates, simply by obtaining second epochs 4-8 years after the event. At present, the search for such hosts is restricted to within the "confusion limit" of θconfus ∼ 0.25′′, but future WFIRST (Wide Field Infrared Survey Telescope) observations will allow one to probe beyond this confusion limit as well.

파장 스위핑 레이저의 스위핑 선형화 (Sweeping Linearization of Wavelength Swept Laser)

  • 엄진섭
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.605-612
    • /
    • 2018
  • 본 논문에서는 선형으로 스위핑하는 파장 스위핑 레이저를 구현하기 위한 새로운 방식을 제안하였으며, 레이저 제작 및 실험을 통하여 1kHz 속도, 80nm 구간의 선형 스위핑 특성을 확인하였다. 제안된 방식은 FFP-TF 인가 파형에 대한 초기 한번의 선 보정만을 필요로 한다. 따라서 기존의 비선형 스위핑 레이저에서 불가피한 후 보정 과정의 번거로움 및 시간 소모문제를 해결해 준다.

SS-OCT용 파장 스위핑 레이저를 위한 스위핑 중심 세팅 자동화 (Sweeping Center Setting Automation for Wavelength Swept Laser used in SS-OCT)

  • 엄진섭
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.324-330
    • /
    • 2017
  • In this paper, the automation of sweeping center setting for wavelength swept laser used in SS-OCT has implemented. For 3 regions where the initial FFP-TF pass wavelength can be located, each different DC voltage pattern is applied to FFP-TF. Through its performance test to the laser, fast and exact setting to sweeping central wavelength, flat sweeping with ${\pm}0.5dB$ fluctuation range, and 10 mW average optical power were obtained. This shows that the realized automatic setting process can replace an inconvenient manual setting operation used for current wavelength swept laser. Additionally it cuts costs for optical spectrum analyzer necessary to laser spectrum monitoring.

정상인들의 다양한 자세에서 두부와 경부의 회전 동안 경부 표층 근육들의 사용 비율 (Comparison of Multimodal Posture of Healthy Adults on the Usage Rate of the Superficial Neck Muscles during Head and Neck Rotation)

  • 황태연;송현승;이남용
    • 대한물리의학회지
    • /
    • 제11권2호
    • /
    • pp.41-52
    • /
    • 2016
  • PURPOSE: This study was conducted to compare the levels of usage of the superficial neck muscles during head rotation in forward head posture and in multimodal postures for improvement of cervical rotation movement impairment. METHODS: To acquire electromyography (EMG) signals from the sternocleidomastoid (SCM-M), upper trapezius (UPT-M), and the splenius capitis (SPC-M) muscles, 11 subjects practiced right rotation of the head in forward head postures (FHP), upright sitting postures (USP), upright sitting postures with supported arms (SUP), standing postures with the arms leaning against the wall (WSP), and four feet postures (FFP), respectively. RESULTS: The left SCM-M was used significantly more in the FFP compared to the FHP, but not in other postures (p<0.01). The left UPT-M was used significantly more in all postures other than the FHP. The right SPC-M was used significantly more in the FFP (p<0.001) and significantly less (p<0.05) in the SUP compared to the FHP. CONCLUSION: During the rotation of the head, although the usage of the SPC-M significantly decreased in SUP compared to FHP but the usage of the SCM-M and UPT-M did not decrease significantly in other postures compared to FHP. Further research is necessary to prove the hypothesis that special postures may reduce the activity of the superficial neck muscles during head rotation.

금은화, 연교 및 황련해독탕 약침이 아토피 피부염 유발 NC/Nga 생쥐에 미치는 영향 (The Effects of Lonicerae Flos, Forsythiae Fluctus and Hwangryunhaedok Decoction Pharmacopuncture on Atopic Dermatitis in NC/Nga Mice)

  • 유정석;김종욱;이창현;이상룡;육태한
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.119-131
    • /
    • 2015
  • Objectives : Atopic dermatitis is a chronic inflammatory skin disease characterized by pruritic and erythematous skin lesions. The purpose of this study was to investigate the suppressive effects of Lonicerae Flos, Forsythiae Fluctus and Hwangryunhaedok Decoction Pharmacopuncture on the development of atopic dermatitis-like skin lesions in NC/Nga Mice. Methods : The Atopic Dermatitis was induced by biostir AD on the mice's back skin. Experimental groups were divided into three including LFP(Lonicerae Flos Pharmacopuncture, EtOH extract), FFP(Forsythiae Fluctus Pharmacopuncture, EtOH extract) and HHP(Hwangryunhaedok Decoction Pharmacopuncture, Hydrodistillation extract). Every second day, the mice of three groups were treated with $0.1m{\ell}$ of pharmacopuncture using a syringe at right and left acupoints ($BL_{13}$), alternatively. On the control group, normal saline was used instead of pharmacopuncture. Subsequently optical observation with a handscope, a clinical skin score, Tissue(general/immune) mast cell, Serum IgE level, Serum histamine level, and Serum lymphokine(IL-2, IL-4, $IFN-{\gamma}{\gamma}$) were measured. Results : FFP and HHP decreased the clinical skin score, the total cell number of mast cells, and the Serum total IgE level and Serum histamine level. In Serum lymphokine levels, all groups were decreased to the IL-4 level, LFP and FFP were increased to the IL-2 level, and LFP was increased to the $IFN-{\gamma}$ level. Conclusions : From the above results, Forsythiae Fluctus Pharmacopuncture (EtOH extract) and Hwangryunhaedok Decoction Pharmacopuncture (Hydrodistillation extract) exerted anti-allergic and anti-inflammatory effects, suggesting a promising agent for improving atopic dermatitis related symptoms.

Prothrombin Complex Concentrate versus Fresh Frozen Plasma in Adult Patients Undergoing Cardiac Surgery: A Systematic Review and Meta-Analysis

  • Patricia Viana;Jessica Hoffmann Relvas;Marina Persson;Thamiris Dias Delfino Cabral;Jorge Eduardo Persson;Jessica Sales de Oliveira;Paulo Bonow;Camila Veronica Souza Freire;Sara Amaral
    • Journal of Chest Surgery
    • /
    • 제57권1호
    • /
    • pp.25-35
    • /
    • 2024
  • Background: Prothrombin complex concentrate (PCC) and fresh frozen plasma (FFP) are commonly used to manage bleeding in patients during cardiac surgery. However, the relative efficacy and safety of these 2 strategies remain uncertain. Methods: MEDLINE, Embase, and Cochrane were searched for studies comparing PCC and FFP in patients who underwent cardiac surgery complicated by bleeding. Review Manager (RevMan) ver. 5.4 (Nordic Cochrane Centre, The Cochrane Collaboration) was used for statistical analysis. Binary and continuous outcomes were compared using pooled risk ratios and mean differences, respectively. The meta-analysis protocol was registered in the International Prospective Register of Systematic Reviews under protocol number CRD42022379144. Results: We included 8 studies with 1,500 patients, of whom 613 (40.9%) received PCC. The mean follow-up period ranged from 28 to 90 days. The PCC group had significantly lower chest tube drainage at 24 hours (mean difference [MD], -148.50 mL; 95% CI, -253.02 to -43.99 mL; p=0.005; I2 =42%). Fewer units of red blood cells (RBCs) were transfused within the first 24 hours (MD, -1.02 units; 95% CI, -1.81 to -0.24 units; p=0.01; I2 =56%), and fewer patients required RBC transfusion within the first 24 hours (risk ratio, 0.85; 95% CI, 0.78-0.93; p<0.007; I2 =45%) in the PCC group. There were no statistically significant differences in secondary outcomes. Nonetheless, a subgroup analysis of randomized controlled trials failed to corroborate the results obtained from the main analysis. Conclusion: Our findings suggest that PCC can be effective, without increased adverse events, when compared with FFP in patients undergoing cardiac surgery complicated by bleeding.

광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석 (Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes)

  • 심종인
    • 한국광학회지
    • /
    • 제11권4호
    • /
    • pp.271-278
    • /
    • 2000
  • 광가입자용 광원으로서 유망한 모드변환기가 집적된 1.3$\mu\textrm{m}$ SSC-FP-LD를 저압 MOVPE결정성장법을 사용해 제작하고 이의 특성을 분석하였다. SSC-LD의 활성영역과 SSC영역은 BJB방법으로 접합하였으며 taper형 도파로 구조를 선택성장법으로 성장하였다. 제작한 SSC-LD의 특성을 측정한 결과 SSC 단면으로 부터의 미분효율 0.23~0.32 mW/mA, FFP의 FWHM값은 9.5$^{\circ}$~12.3$^{\circ}$, 단일모드 광섬유와의 광결합 시 추가광결합손실 -1dB 범위내에서 수평방향으로 $\pm$2.5$\mu\textrm{m}$ 및 수직방향으로 $\pm$2.3$\mu\textrm{m}$의 정렬오차 허용도 등과 같은 양호한 특성을 얻었다. SSC-LD의 문제점들을 이해하고 SSC-LD의 성능향상에 대한 지침을 얻고자 방사모드를 고려한 SSC-LD특성 해석을 행하였다. 해석결과 SSC-LD에서의 비대칭 광출력특성, FFP과 SSC영역단면 근처의 도파로 구조와 비상관성, 온도특성열화 등은 BJB 및 SSC영역내의 불균일한 도파로 구조에 의해 발생되는 방사모드와 두 영역 사이의 좋지 못한 광결합 효율에 의해 발생되는 SHB현상에 기인함을 처음으로 지적하였다.

  • PDF

보건의료종사자의 안면부여과식 마스크의 사용과 밀착도검사의 중요성 (Usage of Filtering-facepiece Masks for Healthcare Workers and Importance of Fit Testing)

  • 한돈희
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.245-253
    • /
    • 2015
  • Objectives: One aim of the study is to compare filtering facepiece masks for healthcare workers between Korea and other countries. The other is to emphasize the importance of fit testing for these masks using an analysis of previous research. Materials: An extensive literature review was performed by searching a number of websites and existing studies. Results: KF94 and KF99 masks certified by the Korean CDC are suitable for healthcare workers as filtering facepiece masks. The standards for these respirators are similar to FFP2 and FFP3 of EN 143 and 149. The performance, such as filtering efficiency, is almost the same between KP94 and N95. It was found that fit testing of respirators for healthcare workers was important to reduce infection risk. Conclusions: KF94 should be emphasized as filtering facepiece masks for healthcare workers rather than N95. Even though Korea has no fit testing regulations, implementing fit testing in healthcare settings is strongly recommended to decrease infection risk.

모유영양아와 인공영양아의 성장과 에너지 및 단백질대사에 관한 종단적 연구 (Longitudinal Study of Growth, Energy and Protein Metabolism of Korean Breast Fed and Formula Fed Infants from 1 to 3 Postpartum Months)

  • 구재옥;최경숙;김원경
    • 대한지역사회영양학회지
    • /
    • 제1권1호
    • /
    • pp.47-60
    • /
    • 1996
  • This study was carried out to investigate growth performance, energy and protein metabolism of breast and formula fed infants from birth to 3 months postpartum. There were four groups : breast fed(BF) and three formula fed groups(FFM, FFN and FFP). There was no significant difference in the height of infants according to feeding method and formula brands. However, mean weight of FFM was significantly higher than that of FFP and BF at 1 and 3 months postpartum, respectively. Mean head circumference of FFN was lowest among groups. The average intake of breast milk was $781.4{\;}{pm}{\;}119.3m{\ell}/day$ and that of formula was $848.6{\;}{pm}{\;}118.5m{\ell}/day$. Mean apparent digestible energy intakes of formula-fed infants and breast-fed infants during 3months were 568.9 $\pm$146.9 kca1/day and 657.9$\pm$212.8 kca1/day, respectively. The average protein intake of brest-fed and formula-fed infants were 8.3$\pm$1.6g/day and 14.1$\pm$14.1 g/day, respectively. The protein intakes of formula-fed infants were significantly higher than those of breast-fed infants at 1, 2, 3 months. The apparent protein digestibility of breast-fed infants was singnificantly higher compared to formula fed infant. These data suggest that RDA for infants be established and breast feeding be encouraged.

  • PDF

파장가변 광섬유 링 레이저를 이용한 아세틸렌(13C2H2) 분광 (Spectroscopy of acetylene (13C2H2) using a tunable erbium-doped fiber ring laser)

  • 유한영;오정미;이동한;문한섭;이원규;박갑동;서호성
    • 한국광학회지
    • /
    • 제14권6호
    • /
    • pp.674-679
    • /
    • 2003
  • 본 연구에서는 C-밴드와 L-밴드 파장(1525 nm-1625 nm)에서 파장 변화가 가능한 광섬유 링 레이저를 제작하고, 이를 이용하여 아세틸렌 분자 전이선에 대한 분광연구를 수행하였다. 제작된 광섬유 링 레이저는 공진기 내부에 FFP-TF(Fiber Fabry-Perot Tunable Filter)를 이용하여 약 102 nm(1510.4-1612.6 nm)의 범위에서 파장을 연속 가변할 수 있었다. 광섬유 링 레이저의 파장가변특성을 이용하여 C-밴드(1525-1565 nm)에서 흡수선이 많은 아세틸렌($^{13}$C$_2$H$_2$)분자에서 50개 이상의 전이선에 대하여 높은 신호대 잡음비를 갖는 흡수 스펙트럼을 측정하였다.