• Title/Summary/Keyword: FFP

Search Result 75, Processing Time 0.036 seconds

MICROLENSING BY KUIPER, OORT, AND FREE-FLOATING PLANETS

  • GOULD, ANDREW
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.4
    • /
    • pp.123-126
    • /
    • 2016
  • Microlensing is generally thought to probe planetary systems only out to a few Einstein radii. Microlensing events generated by bound planets beyond about 10 Einstein radii generally do not yield any trace of their hosts, and so would be classified as free floating planets (FFPs). I show that it is already possible, using adaptive optics (AO), to constrain the presence of potential hosts to FFP candidates at separations comparable to the Oort Cloud. With next-generation telescopes, planets at Kuiper-Belt separations can be probed. Next generation telescopes will also permit routine vetting for all FFP candidates, simply by obtaining second epochs 4-8 years after the event. At present, the search for such hosts is restricted to within the "confusion limit" of θconfus ∼ 0.25′′, but future WFIRST (Wide Field Infrared Survey Telescope) observations will allow one to probe beyond this confusion limit as well.

Sweeping Linearization of Wavelength Swept Laser (파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.605-612
    • /
    • 2018
  • In this paper, a new method for linear sweeping of wavelength swept laser has proposed, and the linear sweeping of 1kHz speed and 80nm range has realized by using this method. The proposed requires only one-shot calibration in the early stage on a wave pattern applied to FFP-TF. This makes the problem with nonlinear swept lasers like a cumbersome and time-consuming signal processing brought on by every recalibration to be resolved.

Sweeping Center Setting Automation for Wavelength Swept Laser used in SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 스위핑 중심 세팅 자동화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.324-330
    • /
    • 2017
  • In this paper, the automation of sweeping center setting for wavelength swept laser used in SS-OCT has implemented. For 3 regions where the initial FFP-TF pass wavelength can be located, each different DC voltage pattern is applied to FFP-TF. Through its performance test to the laser, fast and exact setting to sweeping central wavelength, flat sweeping with ${\pm}0.5dB$ fluctuation range, and 10 mW average optical power were obtained. This shows that the realized automatic setting process can replace an inconvenient manual setting operation used for current wavelength swept laser. Additionally it cuts costs for optical spectrum analyzer necessary to laser spectrum monitoring.

Comparison of Multimodal Posture of Healthy Adults on the Usage Rate of the Superficial Neck Muscles during Head and Neck Rotation (정상인들의 다양한 자세에서 두부와 경부의 회전 동안 경부 표층 근육들의 사용 비율)

  • Hwang, Tae-Yeun;Song, Hyun-Seung;Lee, Nam-Yong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.41-52
    • /
    • 2016
  • PURPOSE: This study was conducted to compare the levels of usage of the superficial neck muscles during head rotation in forward head posture and in multimodal postures for improvement of cervical rotation movement impairment. METHODS: To acquire electromyography (EMG) signals from the sternocleidomastoid (SCM-M), upper trapezius (UPT-M), and the splenius capitis (SPC-M) muscles, 11 subjects practiced right rotation of the head in forward head postures (FHP), upright sitting postures (USP), upright sitting postures with supported arms (SUP), standing postures with the arms leaning against the wall (WSP), and four feet postures (FFP), respectively. RESULTS: The left SCM-M was used significantly more in the FFP compared to the FHP, but not in other postures (p<0.01). The left UPT-M was used significantly more in all postures other than the FHP. The right SPC-M was used significantly more in the FFP (p<0.001) and significantly less (p<0.05) in the SUP compared to the FHP. CONCLUSION: During the rotation of the head, although the usage of the SPC-M significantly decreased in SUP compared to FHP but the usage of the SCM-M and UPT-M did not decrease significantly in other postures compared to FHP. Further research is necessary to prove the hypothesis that special postures may reduce the activity of the superficial neck muscles during head rotation.

The Effects of Lonicerae Flos, Forsythiae Fluctus and Hwangryunhaedok Decoction Pharmacopuncture on Atopic Dermatitis in NC/Nga Mice (금은화, 연교 및 황련해독탕 약침이 아토피 피부염 유발 NC/Nga 생쥐에 미치는 영향)

  • Yu, Jung Suk;Kim, Jong Uk;Lee, Chang Hyun;Lee, Sang Ryong;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.119-131
    • /
    • 2015
  • Objectives : Atopic dermatitis is a chronic inflammatory skin disease characterized by pruritic and erythematous skin lesions. The purpose of this study was to investigate the suppressive effects of Lonicerae Flos, Forsythiae Fluctus and Hwangryunhaedok Decoction Pharmacopuncture on the development of atopic dermatitis-like skin lesions in NC/Nga Mice. Methods : The Atopic Dermatitis was induced by biostir AD on the mice's back skin. Experimental groups were divided into three including LFP(Lonicerae Flos Pharmacopuncture, EtOH extract), FFP(Forsythiae Fluctus Pharmacopuncture, EtOH extract) and HHP(Hwangryunhaedok Decoction Pharmacopuncture, Hydrodistillation extract). Every second day, the mice of three groups were treated with $0.1m{\ell}$ of pharmacopuncture using a syringe at right and left acupoints ($BL_{13}$), alternatively. On the control group, normal saline was used instead of pharmacopuncture. Subsequently optical observation with a handscope, a clinical skin score, Tissue(general/immune) mast cell, Serum IgE level, Serum histamine level, and Serum lymphokine(IL-2, IL-4, $IFN-{\gamma}{\gamma}$) were measured. Results : FFP and HHP decreased the clinical skin score, the total cell number of mast cells, and the Serum total IgE level and Serum histamine level. In Serum lymphokine levels, all groups were decreased to the IL-4 level, LFP and FFP were increased to the IL-2 level, and LFP was increased to the $IFN-{\gamma}$ level. Conclusions : From the above results, Forsythiae Fluctus Pharmacopuncture (EtOH extract) and Hwangryunhaedok Decoction Pharmacopuncture (Hydrodistillation extract) exerted anti-allergic and anti-inflammatory effects, suggesting a promising agent for improving atopic dermatitis related symptoms.

Prothrombin Complex Concentrate versus Fresh Frozen Plasma in Adult Patients Undergoing Cardiac Surgery: A Systematic Review and Meta-Analysis

  • Patricia Viana;Jessica Hoffmann Relvas;Marina Persson;Thamiris Dias Delfino Cabral;Jorge Eduardo Persson;Jessica Sales de Oliveira;Paulo Bonow;Camila Veronica Souza Freire;Sara Amaral
    • Journal of Chest Surgery
    • /
    • v.57 no.1
    • /
    • pp.25-35
    • /
    • 2024
  • Background: Prothrombin complex concentrate (PCC) and fresh frozen plasma (FFP) are commonly used to manage bleeding in patients during cardiac surgery. However, the relative efficacy and safety of these 2 strategies remain uncertain. Methods: MEDLINE, Embase, and Cochrane were searched for studies comparing PCC and FFP in patients who underwent cardiac surgery complicated by bleeding. Review Manager (RevMan) ver. 5.4 (Nordic Cochrane Centre, The Cochrane Collaboration) was used for statistical analysis. Binary and continuous outcomes were compared using pooled risk ratios and mean differences, respectively. The meta-analysis protocol was registered in the International Prospective Register of Systematic Reviews under protocol number CRD42022379144. Results: We included 8 studies with 1,500 patients, of whom 613 (40.9%) received PCC. The mean follow-up period ranged from 28 to 90 days. The PCC group had significantly lower chest tube drainage at 24 hours (mean difference [MD], -148.50 mL; 95% CI, -253.02 to -43.99 mL; p=0.005; I2 =42%). Fewer units of red blood cells (RBCs) were transfused within the first 24 hours (MD, -1.02 units; 95% CI, -1.81 to -0.24 units; p=0.01; I2 =56%), and fewer patients required RBC transfusion within the first 24 hours (risk ratio, 0.85; 95% CI, 0.78-0.93; p<0.007; I2 =45%) in the PCC group. There were no statistically significant differences in secondary outcomes. Nonetheless, a subgroup analysis of randomized controlled trials failed to corroborate the results obtained from the main analysis. Conclusion: Our findings suggest that PCC can be effective, without increased adverse events, when compared with FFP in patients undergoing cardiac surgery complicated by bleeding.

Fabrication and analysis of $1.3\mum$ spot-size-converter integrated laser diodes (광모드변환기가 집적된 $1.3\mum$ SC-FP-LD 제작 및 특성 해석)

  • 심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.271-278
    • /
    • 2000
  • We have fabricated and analyzed the lasing characteristics of 1.3$\mu\textrm{m}$ Spot-Size-Converter (SSC) integrated Fabry-Perot (FP) laser diodes, which are very promising light sources for optical subscriber networks. SSC-LDs has been developed by BIB (buttjoint-built-in) coupling and selective MOVPE growth. High-performances were achieved such as the slope efficiency from the SSC facet of 0.23-0.32 mW/mA, the full-width at the half maximum of the far-field pattern (FFP) of 9.5$^{\circ}$~12.3$^{\circ}$, the alignment tolerances of $\pm$2.3$\mu\textrm{m}$ and $\pm$2.5$\mu\textrm{m}$ within the extra-coupling loss of 1 dB for the vertical and parallel directions, respectively. These experimental results were compared to theoretical ones in order to clarify the operational problems and give a good design direction of the fabricated SSC-LDs. It was revealed that an asymmetric output power from the facets, an irrelevancy of FFP and the waveguide structure around SSC facet region, and a poor temperature characteristics were originated from the scattering in the BIB and SSC sections and SHB effect in the active section for the first time.t time.

  • PDF

Usage of Filtering-facepiece Masks for Healthcare Workers and Importance of Fit Testing (보건의료종사자의 안면부여과식 마스크의 사용과 밀착도검사의 중요성)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • Objectives: One aim of the study is to compare filtering facepiece masks for healthcare workers between Korea and other countries. The other is to emphasize the importance of fit testing for these masks using an analysis of previous research. Materials: An extensive literature review was performed by searching a number of websites and existing studies. Results: KF94 and KF99 masks certified by the Korean CDC are suitable for healthcare workers as filtering facepiece masks. The standards for these respirators are similar to FFP2 and FFP3 of EN 143 and 149. The performance, such as filtering efficiency, is almost the same between KP94 and N95. It was found that fit testing of respirators for healthcare workers was important to reduce infection risk. Conclusions: KF94 should be emphasized as filtering facepiece masks for healthcare workers rather than N95. Even though Korea has no fit testing regulations, implementing fit testing in healthcare settings is strongly recommended to decrease infection risk.

Longitudinal Study of Growth, Energy and Protein Metabolism of Korean Breast Fed and Formula Fed Infants from 1 to 3 Postpartum Months (모유영양아와 인공영양아의 성장과 에너지 및 단백질대사에 관한 종단적 연구)

  • 구재옥;최경숙;김원경
    • Korean Journal of Community Nutrition
    • /
    • v.1 no.1
    • /
    • pp.47-60
    • /
    • 1996
  • This study was carried out to investigate growth performance, energy and protein metabolism of breast and formula fed infants from birth to 3 months postpartum. There were four groups : breast fed(BF) and three formula fed groups(FFM, FFN and FFP). There was no significant difference in the height of infants according to feeding method and formula brands. However, mean weight of FFM was significantly higher than that of FFP and BF at 1 and 3 months postpartum, respectively. Mean head circumference of FFN was lowest among groups. The average intake of breast milk was $781.4{\;}{pm}{\;}119.3m{\ell}/day$ and that of formula was $848.6{\;}{pm}{\;}118.5m{\ell}/day$. Mean apparent digestible energy intakes of formula-fed infants and breast-fed infants during 3months were 568.9 $\pm$146.9 kca1/day and 657.9$\pm$212.8 kca1/day, respectively. The average protein intake of brest-fed and formula-fed infants were 8.3$\pm$1.6g/day and 14.1$\pm$14.1 g/day, respectively. The protein intakes of formula-fed infants were significantly higher than those of breast-fed infants at 1, 2, 3 months. The apparent protein digestibility of breast-fed infants was singnificantly higher compared to formula fed infant. These data suggest that RDA for infants be established and breast feeding be encouraged.

  • PDF

Spectroscopy of acetylene (13C2H2) using a tunable erbium-doped fiber ring laser (파장가변 광섬유 링 레이저를 이용한 아세틸렌(13C2H2) 분광)

  • 유한영;오정미;이동한;문한섭;이원규;박갑동;서호성
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.6
    • /
    • pp.674-679
    • /
    • 2003
  • We fabricated erbium-doped fiber ring laser with a new structure that can operate in C- & L-band wavelength region. The wave-length of the laser can be tuned continuously over 102 nm between 1510.4-1612.6 nm by insertion of the fiber Fabry-Perot tunable filter (FFP-TF) in the ring cavity. By use of the wavelength tunable characteristics of our fiber laser, we measured absorption spectra of more than fifty transition lines of the acetylene ($^{13}$ C$_2$H$_2$) molecule with high signal to noise ratio (SNR).