• Title/Summary/Keyword: FDD

Search Result 180, Processing Time 0.027 seconds

A Study on relative distance estimation for asynchronous FDD using Two-way ToA (비동기식 FDD에서 Two-way ToA를 통한 상대거리 측정에 관한 연구)

  • Song, Young-Hwan;Park, Jae-Soo;Shin, Young-Jun;Yoon, Chang-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.12
    • /
    • pp.1175-1186
    • /
    • 2016
  • The relative distance estimation technique is important to Location-Based Service(: LBS) in a wireless communication environment. In this paper, we propose a scheme for measuring the relative distance by utilizing a frame structure of a physical layer in asynchronous Frequency Division Duplexing(: FDD) when the Internal and external infrastructure for position measurement cannot be used. The proposed method is suitable for continuous distance measurement. The test results showed that the proposed method has the accuracy of less than 10 meters on average.

Development of fault detection and diagnosis system for the heat source apparatus of building air-conditioning system (공조시스템의 열원기기에 대한 고장검출 및 진단 시스템 개발)

  • Han, Dong-Won;Park, Jong-Soo;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.30-35
    • /
    • 2008
  • This paper describes a fault detection and diagnosis (FDD) system developed for the heat source apparatus in building air-conditioning system. As HVAC&R systems in building become complex and instrumented with highly automated controllers, the processes and systems get more difficult for the operator to understand and detect the mal-functions. Poorly maintained, degraded, and improperly controlled equipment wastes an estimated 15% to 30% of energy used in commercial building. When operating a complex facility, FDD system is beneficial in equipment management to provide the operator with tools which can help in decision making for recovery from a failure of the system. Automated FDD for HVAC&R system has the potential to reduce energy and maintenance costs and improves comfort and reliability. Over the last decade there has been considerable research for developing FDD system for HVAC&R equipment. However, they are being made too much of a theoretical study, so only a small of FDD methods are deployed in the field. This study deduced an actual defect source for the heat source apparatus and suggested a low price FDD method which is ready to be deployed in the field.

  • PDF

An Enhanced AGC Structure and P-SCH Detection Method for Initial Cell Search in 3GPP LTE FDD/TDD Dual Mode Downlink Receiver (3GPP LTE FDD/TDD 듀얼 모드 하향 링크 수신기의 초기 셀 탐색을 위한 개선된 AGC 구조 및 P-SCH 검출 기법)

  • Chung, Myung-Jin;Jang, Jun-Hee;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3C
    • /
    • pp.302-313
    • /
    • 2010
  • In this paper, we propose an enhanced AGC (Automatic Gain Control) structure and P-SCH detection method for initial cell search in 3GPP (3rdGenerationPartnershipProject) LTE (Long Term Evolution) FDD(Frequency Division Duplex) / TDD (Time Division Duplex) dual mode system. Since TDD frame structure consists of uplink subframe and downlink subframe, conventional AGC structure causes P-SCH detection performance degradation by increase of AGC variation due to signal power difference between uplink and downlink subframe. Also, P-SCH detection performance is degraded by distortion of P-SCH correlation characteristic in frequency offset and multipath fading channel environments. Therefore, we propose an AGC structure which can minimize P-SCH detection performance degradation with stable operation in 3GPP LTE TDD mode as well as FDD mode. Also we propose a P-SCH detection method which can reduce distortion of correlation chareteristics in frequency offset and multipath fading environments and obtain good P-SCH detection performance. Simulation results show that the proposed AGC structure and P-SCH detection method have stable AGC operation and excellent P-SCH detection performance for 3GPP LTE TDD / FDD dual mode downlink receiver in various channel environments.

A downlink beam synthesized method considering phase matching between common overhead channel and traffic channel in FDD/CDMA systems (FDD/CDMA 시스템에서 공통채널과 통화채널의 위상정합을 고려한 순방향 빔 합성 기법)

  • 이준성;이충용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.11
    • /
    • pp.67-72
    • /
    • 2004
  • In this paper, we propose a downlink beamforming method which is considered common pilot channel for coherent detection and dedicated traffic channel for desired user in FDD/CDMA systems. The existing downlink beamforming system produces phase mismatch between traffic and pilot signals at desired mobile as well as interference to other mobiles. A new downlink beamforming method can solve above problem based on least squares method between reference function and beamforming function. A numerical analysis shows that the proposed downlink beamforming method matches well and gives low BER performance.

Beamforming Based CSI Reference Signal Transmission for FDD Massive MIMO Systems (주파수 분할 방식의 거대 다중 안테나 시스템을 위한 빔형성 기반의 채널상태정보 기준신호 전송기술)

  • Hong, Jun-Ki;Jo, Han-Shin;Mun, Cheol;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.5
    • /
    • pp.520-530
    • /
    • 2016
  • Since FDD massive MIMO (multiple-input multiple-output) system deploys hundreds of transmit antennas at base station (BS) compared to conventional MIMO system, the overhead of transmitting channel state information reference signal (CSI-RS) increases proportionally to the number of transmit-antennas. To overcome these disadvantages, we proposed beamforming based CSI-RS transmission technique for FDD massive MIMO system which transmit CSI-RS by limited amount of downlink resources.

A Study on Interference Analysis between Base Stations with FDD and TDD Modes for IMT-2000 (FDD 및 TDD 모드 채용 IMT-2000 시스템 기지국간 간섭분석 연구)

  • 이일근;이형수;이정규;신경철;김경태
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.11-17
    • /
    • 2001
  • This paper introduces an interference analyzer based on the statistical approach called the Monte Carlo methodology, which has been chosen as one of the interference analyzing techniques in ITU-R. Furthermore, using the interference analyzer developed in this paper with modified Hata model, computer simulation is performed to examine probability of interference affecting between the base stations with FDD and TDD modes for IMT-2000. Through the simulation results, it is confirmed that two different systems with FDD/TDD modes of same frequency bands can be simultaneously used in a cell without significant interference, under the parameter conditions specified in this paper.

  • PDF

Fault Detection and Diagnosis based on Fuzzy Algorithm in the Injection Molding Machine Barrel Temperature (사출 성형기 Barrel 온도에 관한 퍼지알고리즘 기반의 고장 검출 및 진단)

  • 김훈모
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.11
    • /
    • pp.958-962
    • /
    • 2003
  • We acquired data of injection molding machine in operation and stored the data in database. We acquired the data of injection molding machine for fault detection and diagnosis (FDD) continuously and estimated the fault results with a fuzzy algorithm. Many of FDD are applied to a huge system, nuclear power plant and a computer numerical control(CNC) machine for processing machinery. But, the research of FDD is rare in injection molding machine compare with computer numerical control machine. We appraise the accuracy of the FDD and the limit of the application to the injection molding machine. We construct the fault detection and diagnosis system based on fuzzy algorithm in the injection molding machine. Data of operating injection molding machine are acquired in order to improve the reliability of detection and diagnosis.

On Mobility-Supporting Transmit Beamforming in MISO FDD Wireless Systems

  • Lee, Woo-Kwon;Sepko, Brian J.
    • Journal of Communications and Networks
    • /
    • v.10 no.3
    • /
    • pp.308-315
    • /
    • 2008
  • When operating in frequency-division duplex (FDD) mode, transmit beamforming in multiple-input single-output (MISO) wireless communication systems typically requires accurate knowledge of downlink channel state information (CSI) at the transmitter. In practical FDD systems, obtaining such downlink CSI at the transmitter is challenging, if not impractical. To circumvent such challenge and support user mobility, we present a new method for transmit beamforming based on simple beam-control commands (BCCs) in MISO FDD mobile systems. We then numerically evaluate the effects of BCC errors in terms of transmit power efficiency, system capacity, and outage probability.

On-Line Fault Diagnosis System using Neural Network (신경망을 이용한 실시간 고장 진단 시스템)

  • 김문성;유승선;소정훈;곽훈성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11C
    • /
    • pp.75-84
    • /
    • 2001
  • In this paper, we propose an on-line FDD(Fault Detection and Diagnosis) system based on the three layer feed-forward neural network which is trained by the back-propagation teaming algorithm. We implement the on-line fault detection and diagnosis system by Visual C++ and Visual Basic. The proposed FDD system is applied to an air handling unit in operation. Experimental results show the high performance of our system in the task of fault detection and diagnosis.

  • PDF

The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit (공조설비용 고장진단시스템의 실시간 진단실험)

  • 소정훈;유승신;경남호;신기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF