• Title/Summary/Keyword: FD

Search Result 876, Processing Time 0.022 seconds

The Efficacy of a Combination Administration of GnRH Agonist(Lupron) and Gonadotropins for Controlled Ovarian Hyperstimulation in IVF Program (체외수정시술을 위한 과배란유도시 GnRH Agonist(Lupron)와 성선자극호르몬 복합 투여의 효용성에 관한 연구)

  • Moon, Shin-Yong;Lee, Jin-Yong;Chang, Yoon-Seok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.17 no.1
    • /
    • pp.29-44
    • /
    • 1990
  • In 105 patients with the past history of poor response to the previous controlled ovarian hyperstimulation(COH) due to poor follicular growth or premature LH surge, the effectiveness of pituitary suppression with gonadotropin-releasing hormone agonist(GnRH agonist) in IVF/GIFT program was evaluated in 112 cycles of COH using a combination regimen of Leuprolide acetate (Lupron TAP Pharmaceuticals, USA) and FSH/hMG or pure FSH from May to December, 1989 at SNUH. Starting on day 21 of the menstrual cycle(MCD #21, Day 1), Lupron (1.0mg/day, subcutaneous) was administered once a day till next MCD #3(suppression phase). After the confirmation of pituitary suppression, ovarian follicular growth was stimulated with FSH/hMG or pure FSH from MCD #3(Day + 1), and Lupron was continued with hMG or FSH until hCG administration (D 0) (stimulation phase). After suppression phase, serum E2 level decreased from 183.7${\pm}$95.1(Day 1) to 17.4${\pm}$12.3pg/ml (Day +1), and serum progesterone level from 19.17${\pm}$8.67 to 0.12${\pm}$0.05ng/ml. But there was no decresas in serum LH and FSH levels; LH from 12.74${\pm}$6.21 to 15.49${\pm}$4.93mIU/ml,FSH from 7.60${\pm}$3.84 to 8.58${\pm}$3.15 rnlU/ml. There was no occurrence of premature LH surge during COH. Eleven cycles(9.8%) were cancelled due to poor follicular growth during stimulation phase, and 3 cycles (3.0%) failed in the transvaginal oocytes fretrieval. Serum E2 level was 1366.8${\pm}$642.4 on D 0 and 1492.3${\pm}$906.9pg/ml on D+1. 7.00${\pm}$3.32 follicles(FD${\geq}$12mm) were observed on D 0, and 6.11${\pm}$4.15 oocytes were retrieved, with the oocyte retrieval rate per follicle of 95.0%. 3.59${\pm}$2.57 oocytes were fertilized and cleaved with the oocyte cleavage rate of 55.7%. In 83 IVF patients, 4.08${\pm}$2.39 embryos were transferred, and 16 pregnancies were obtained with the pregnancy rate per ET 2.39 mebryos were transferred, and 16 pregnancies were obtained with the pregnancy rate per ET of 19.3%. In 6 GIFT patients, 7.83${\pm}$3.31 oocytes were retrieved and transferred with maximum number of 6, but no pregnancy was obtained. When compared with the previous 108 cycles of COH using FSH/hMG or pure FSH regimen, the cancellation rate during COH was significantly decreased, and all the parameters of the outcome of COH including the pregnancy rate were increased. These data suggest that GnRH agonist therapy for pituitary suppression is an effective adjunct to the current gonadotropin regimens for COH in IVF/GIFT and can increase the probability of oocytes retrieval and pregnancy, especially in the previous poor responders.

  • PDF

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire (ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구)

  • Lee, Yeon-Ho;Lee, Joo-Hyung;Kim, Soo-Jin;Chon, Sung-Ho;Choi, Byoung-Chul;Oh, Seung-Ju;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.147-155
    • /
    • 2020
  • This paper presents a study on the development of a fire extinguishing agent and extinguishing system for an energy storage system (ESS) fire. The fire extinguishing agent designed to extinguish an ESS fire is a highly permeable fire extinguisher that reduces the surface tension and viscosity while bringing about cooling action. This is the main extinguishing effect of this type of wetting agent, which displays the characteristics of fire extinguishing agents used for penetrating the battery cells inside the ESS module. For the fire extinguishing system, a local application system was designed to suppress fire on a rack-by-rack basis. A 360° rotating nozzle was inserted into the rear hall of the ESS module, and general nozzles were installed in the rack to maximize the fire extinguishing effect. The fire extinguishing agent was strongly discharged by virtue of the gas release pressure. Experiments on fire suppression performance with ESS module 1 unit and module 3 units showed that all visible flames were extinguished in 8 s and 9 s, respectively, by the fire extinguishing agent. In addition, based on confirming reignition for 600 s after the fire extinguishing agent was exhausted, it was confirmed that the ESS fire was completely extinguished without reignition in all fire suppression performance experiments.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

Study on Cosmeceutical Activities and Anti-inflammatory Activities of Magnolia biondii Extracts (신이화(辛夷花, Magnoliae Flos)추출물의 화장품약리활성 및 항염증효과에 관한 연구)

  • Kim, Young-Hun;Sung, Ji-Yeon;Seo, Kyo-Seong;Shin, Jae-Cheon;Kim, Byung-So;Yeum, Jeong-Hyun;Lee, Jin-Tae
    • Journal of Life Science
    • /
    • v.22 no.6
    • /
    • pp.730-735
    • /
    • 2012
  • Existing pharmaceutical studies show that Magnolia biondii is effective in treating rhinitis and in reducing cholesterol, given its endogenous, volatile ingredients. The study herein seeks to assess the cosmeceutical activities and anti-inflammatory activities of Magnolia biondii extracts for possible application as cosmetic ingredients. The cosmeceutical and anti-inflammatory activities were investigated using hydroxyl radical scavenging, superoxide dismutase (SOD)-like activity, xanthine oxidase (XO) inhibition, cell viability, nitric oxide (NO) inhibition, and inducible nitric oxide synthase (iNOS) expression by Western blotting. Magnolia biondii extracts were identified to have antioxidant activities in hydroxyl free radical scavenging, SOD-like activity, and XO inhibition. In testing the anti-inflammatory activities of the extracts, NO production was inhibited in a dose-dependent manner. Additionally, in a dose-dependent manner, the Magnolia biondii extracts were able to suppress iNOS expression in LPS-stimulated RAW 264.7 macrophage cells. From these results, Magnolia biondii showed adequate potential for application in cosmetic production and related industries as well as a functional material.

Correlation Study between Electrogastrography and Nepean Dyspepsia Index (NDI) in Clinical Practice Students (임상실습 학생을 대상으로 한 위전도검사와 Nepean Dyspepsia Index(NDI) 설문검사와의 연관성 연구)

  • Choi, Jin-yong;Bae, Go-eun;Shim, So-hyun;Seo, Hee-jeong;Seo, Hyung-bum;Choi, Jun-yong;Kwon, Jung-nam;Lee, In;Hong, Jin-woo;Yun, Young-ju;Park, Seong-ha;Han, Chang-woo;Kim, So-yeon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.732-740
    • /
    • 2018
  • Objective: The aim of this study was to find a correlation between the Nepean Dyspepsia Index (NDI) and electrogastrography (EGG) in clinical practice students. Methods: In total, 28 students were enrolled. NDI and EGG were measured in all students. NDI was classified as abnormal when the score was 11 or more. In EGG, standard 1 was classified as abnormal if the preprandial or postprandial percentage of normal gastric slow waves of Ch3 was less than 70% or if power ratio of Ch3 was less than 1. Standard 2 was classified as abnormal if standard 1 was met or if the percentage of normal gastric slow waves of Ch3 decreased after meals. Results: NDI and EGG had no statistically meaningful correlation when standard 1 was used, but NDI and EGG had statistically meaningful correlation when standard 2 was used. Conclusions: These findings suggest that NDI and EGG are correlated and that EGG can be used to evaluate the degree of dyspepsia.

젖산균의 Plasmid DNA 분리방법 및 Electroporation에 의한 젖산균의 형질전환에 관한 연구

  • Kim, Seon-Gi
    • 한국유가공학회:학술대회논문집
    • /
    • 1997.05a
    • /
    • pp.41-61
    • /
    • 1997
  • 젖산균의 유전자 연구를 촉진하기 위해 간단하고 신속한 plasmid DNA의 분리방법과 electro-poration을 이용하여 vector plasmid의 간단하고 신속한 전이방법을 얻기 위해 젖산균의 형질전환에 영향하는 요인에 대하여 연구하였으며 연구결과는 다음과 같다. 1. O'Sullivan과 Klaenhammer의 방법을 개선하여 젖산균 plasmid DNA의 분리에 좋은 결과를 얻을 수 있는 신속하고 쉬운 방법을 고안하였으며, genomic DNA 분리에 이용되는 guanidium thio-cyanate 처리방법을 plasmid의 분리에 적용할 수 있었다. 2. L. casei, L. acidophilus. L. delbruekii var. bulgaricus. L. brevis와 L. plantarum 균주에서 plasmid를 확인하였으며, 돼지 분에서 분리된 L. lactis ssp. lactis. L. fermentum과 L. plantarum에서도 plasmid를 분리 확인하였다. 3. Lactococci의 plasmid분리는 lactobacilli와는 달리 mutanolysin의 처리없이도 잘 되었으며, L. lactis ssp. lactis와 Ent. faecalis에서 plasmid를 확인하였다. 4. E. coli plasimd 분리에 이용되는 MPS membrane filter 방법으로 젖산균 plasmid pLZ12의 분리가 가능하였으나, 세포파편이 filter를 막아 사용에 어려움이 있는 것으로 확인되었다. 5. Plasmid 분리없이 electroporation을 이용한 세포 대 세포 전이법으로 간편하고 빠르게 E. coli DH5${\alpha}$에 E. coli Jm109의 plasmid pBX19, pBR322를 전이시켰다. 6. L. lactis ssp. lactis 균주에 lysozyme 처리시 30${\sim}$80%의 생존율을 보였으며, 대부분의 L. acidophilus 균주의 경우 약 70%의 생존율을 보였다. L. casei 102S의 경우는 45분간 처리 시에도 100%의 생존율을 보였다. 8. L. lactis ssp. lactis 균주에 pLZ12를 6.0kV에서 전이시킨 결과 12.5kV에서보다 형질전환 효율이 훨씬 높았으며 lysozyme 처리에 의해 형질전환 효율이 증가되었다. 9. L. acidophilus 균주에 pLZ12를 전이시 6.0kV에서는 전이가 모두 이루어졌으나, 12.5kV에서는 L. acidophilus WIESBY와 NCFM에서 전이가 이루어지지 않았으며, lysozyme 처리 후 pLZ12를 전이시켰을 때 12kV보다 6.0kV에서 형질전환 효율이 증가되었다. 10. Gene Pulser와 Progenitor II를 사용하여 pLZ12를 L. lactis ssp. lactis 균주에 전이하였을 때 Gene Pulser에 비해 Progenitor II의 형질전환 효율이 현저히 떨어졌다. L. acidophilus HY7008과 HY7001은 두 기기 모두 형질전환이 이루어졌으나, L. acidophilus WEISBY와 NCFM은 Progeni-tor II에서 전이가 일어나지 않았으며, Gene Pulser에서 전이균주를 얻어 두 electroporator간에 형질전환 효율의 차이를 보였다. 11. L. casei 102S에 pLZ12를 electroporation시 낮은 전압에서 형질전환 효율이 비교적 좋았으며, 배양 시기를 달리하여 전이시켰을 때 대수생장 말기의 세포가 형질전환 효율이 좋았다. 12. L. casei 102S세포를 각각 10% glycerol, EB, 2차 증류수 등에 녹여 electroporation을 실시하였을 때 각각 $3.8{\times}10^3$, $5.0{\times}10^2$,1.5${\times}10^2$cfu의 형질전환 효율을 보였으며, 1.0mM HEPES, TE buffer를 사용하였을 때에는 전이가 이루어지지 않았다. 13. Plasmid pLZ12의 농도를 달리하여 electroporation을 하였을 때 형질전환 효율이 농도에 비례하여 증가하였다. 14. L. casei 102S에 대수생장 말기의 세포를 채취하여 10% glycerol, 200 Ohms, 25 ${\mu}$FD, 10kV/cm로 plasmid pLZ12를 electroporation할 때 최대 형질전환 효율인 3.8${\times}$10$^{3}$cfu를 얻었으며, lysozyme 처리가 다른 젖산균과는 달리 형질전환 효율을 증가시키지 못하였다. 15. L. casei 102S 세포를 10% glycerol과 EB에 녹여 -20$^{\circ}C$에서 냉동시킨 다음 1일과 7일 후의 세포를 electroporation한 결과 냉동시 세포에 손상을 주는 것으로 인식되었다.

  • PDF

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.

Implementation of AC Direct Driver Circuit for Ultra-slim LED Flat Light System (초슬림 LED 면조명 기구용 교류 직결형 구동 회로 구현)

  • Cho, Myeon-Gyun;Choi, Hyo-Sun;Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4177-4185
    • /
    • 2012
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent lamps because of its eco-friendly characteristics. LEDs are also actively used to design green building system and to make outdoor billboard as a back-light system due to its high energy efficiency. In this paper, we have developed AC direct driver for $12{\times}12$ FLB(flexible LED board) and LED flat light without SMPS. It has LID-PC-R101B driver IC that can support the high power factor and be composed of LED switching circuit in group. Also, an elaborate system designs can guarantee a high luminous efficiency, a high reliability and a low power consumption. The proposed FLB has the ultra slim shape of $450{\times}450$ mm, width of 4 mm and weight of 280 g. In the end, we have developed a prototype of FLB for billboard and flat light for room lighting with AC direct driver iposrder to verify the performance of the proposed system.

Crystal Structure of a Carbon Monoxide Sorption Complex of Fully $Ca^{2+}$-Exchanged Zeolite X (제올라이트 X 착물의 결정구조)

  • Lee, Seok-Hee;Kim, Yong-Gwon;Jeong, Gyoung-Hwa;Kim, Nam-Seok;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2005
  • The structure of a carbon monoxide sorption complex of dehydrated fully $Ca^{2+}$-exchanged zeolite X, $|Ca_{46}(CO)_{27}|[Si_{100}Al_{92}O_{384}]$-FAU, has been determined in the cubic space group $Fd\;{\overline{3}}$ at $21^{\circ}C$ (a = 24.970(4) ) by single-crystal X-ray diffraction techniques. The crystal was prepared by ion exchange in a flowing stream of 0.05 M aqueous ${Ca(NO_3)_2}$ for three days, followed by dehydration at $400^{\circ}C$ and $2{\times}10^{-6}$ Torr for two days, and exposure to 100 Torr of zeolitically dry carbon monoxide gas at $21^{\circ}C$. The structure was determined in this atmosphere and was refined, using the 356 reflections for which $F_o$ > $4{\sigma}(F_o)$, to the final error indices $R_1$ = 0.059 and $wR_2$ = 0.087. In this structure, $Ca^{2+}$ ions occupy three crystallographic sites. Sixteen $Ca^{2+}$ ions fill the octahedral site I at the centers of hexagonal prisms (Ca-O = 2.415(7) ${\AA}$). The remaining 30 $Ca^{2+}$ ions are found at two nonequivalent sites II (in the supercages) with occupancies of 3 and 27 ions. Each of these $Ca^{2+}$ ions coordinates to three framework oxygens, either at 2.276(10) or 2.298(8) ${\AA}$, respectively. Twenty-seven carbon monoxide molecules have been sorbed per unit cell, three per supercage. Each coordinates to one of the latter 16 site-II $Ca^{2+}$ ions: C-Ca = 2.72(8) ${\AA}$. The imprecisely determined N-C bond length, 1.26(14) ${\AA}$, differs insignificantly from that in carbon monoxide(g), 1.13 ${\AA}$.