• Title/Summary/Keyword: FAST Imaging

Search Result 460, Processing Time 0.024 seconds

A Fast Seam Tracking Algorithm for Laser Welding (레이져 용접을 위한 고속 용접선 추적 알고리즘)

  • 배재욱
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.52-55
    • /
    • 1997
  • This paper discusses an automatic visual-servoing system, in which a laser and a CCD camera are used for imaging the pattern of joint groove. The algorithm used here is simple and robust to find out the gap width and gap center. As a consequence, the speed of algorithm is very fast and optimized. A feature of this system is that it processes only by summing the vertical line and horizontal line of screen without any image preprocessing in order to get the energy information of lines alternatively. It is practical and useful for the system requiring a fast process time of vision.

  • PDF

Nonlinear 3D Image Correlator Using Fast Computational Integral Imaging Reconstruction Method (고속 컴퓨터 집적 영상 복원 방법을 이용한 비선형 3D 영상 상관기)

  • Shin, Donghak;Lee, Joon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2280-2286
    • /
    • 2012
  • In this paper, we propose a novel nonlinear 3D image correlator using a fast computational integral imaging reconstruction (CIIR) method. In order to implement the fast CIIR method, the magnification process was eliminated. In the proposed correlator, elemental images of the reference and target objects are picked up by lenslet arrays. Using these elemental images, reference and target plane images are reconstructed on the output plane by means of the proposed fast CIIR method. Then, through nonlinear cross-correlations between the reconstructed reference and the target plane images, the pattern recognition can be performed from the correlation outputs. Nonlinear correlation operation can improve the recognition of 3D objects. To show the feasibility of the proposed method, some preliminary experiments are carried out and the results are presented by comparing the conventional method.

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques (3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교)

  • Jeong, Jee-Young;Yoo, So-Young;Jang, Kyung-Mi;Eo, Hong;Lee, Jung-Hee;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the usefulness of fast inversion recovery (FIR) and magnetization-prepared three dimensional gradient echo sequence (3D GRE) T1-weighted sequences for neonatal brain imaging compared with spin echo (SE) sequence in a 3T MR unit. Materials and Methods: T1-weighted axial SE, FIR and 3D GRE sequences were evaluated from 3T brain MR imaging in 20 neonates. The signal-to-noise ratio (SNR) of different tissues was measured and contrast-to-noise ratios (CNR) were determined and compared in each of the sequences. Visual analysis was carried out by grading gray-white matter differentiation, myelination, and artifacts. The Wilcoxon signed ranked test was used for evaluation of the statistical significance of CNR differences between the sequences. Results: Among the three sequences, the 3D GRE had the best SNRs. CNRs obtained with FIR and 3D GRE were statistically superior to those obtained with SE; these CNRs were better on the 3D GRE compared to the FIR. Gray to white matter differentiation and myelination were better delineated on the FIR and 3D GRE than the SE. However, motion artifacts were more commonly observed on the 3D GRE and flow-related artifacts of vessels were frequently seen on the FIR. Conclusion: FIR and 3D GRE are valuable alternative T1-weighted sequences to conventional SE imaging of the neonatal brain at 3T providing superior image quality.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Magnetic Resonance Imaging in Thoracic Disease (흉부질환의 자기공명영상)

  • Song, Koun-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.345-352
    • /
    • 1993
  • The role of magnetic resonance(MR) imaging in the evaluation of thoracic disease has been limited Nontheless, MR has inherent properties of better contrast resolution than CT allowing tissue-specific diagnosis. MR has capability of direct imaging in sagittal, coronal, and oblique planes which provide better anatomic information than axial images of CT such as lesions in the pulmonary apex, aorticopulmonary window, peridiaphragmatic region, and subcarinal region. MR is sensitive to blood flow making it an ideal imaging modality for the evaluation of cardiovascular system of the thorax without the need for intravenous contrast media. Technical developments and better control of motion artifacts have resulted in improved image quality, and clinical applications of MR imaging in thoracic diseases have been expanded. Although MR imaging is considered as a problem-solving tool in patients with equivocal CT findings, MR should be used as the primary imaging modality in the following situations: 1) Evaluation of the cardiovascular abnormalities of the thorax 2) Evaluation of the superior sulcus tumors 3) Evaluation of the chest wall invasion or mediastinal invasion by tumor 4) Evaluation of the posterior mediastinal mass, especially neurogenic tumor 5) Differentiation of fibrosis and residual or recurrent tumor, especially in lymphoma 6) Evaluation of brachial plexopathy With technical developments and fast scan capabilities, clinical indications for MR imaging in thorax will increase in the area of pulmonary parenchymal and pulmonary vascular imaging.

  • PDF

Beam-scanning Imaging Needle for Endoscopic Optical Coherence Tomography

  • Yang, Woohyeok;Hwang, Junyoung;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.532-537
    • /
    • 2021
  • We present a compact endoscopic probe in a needle form which has a fast beam-scanning capability for optical coherence tomography (OCT). In our study, a beam-scanning OCT imaging needle was fabricated with a 26G syringe needle (0.46 mm in outer diameter) and a thin OCT imaging probe based on the stepwise transitional core (STC) fiber. The imaging probe could freely rotate inside the needle for beam scans. Hence, OCT imaging could be performed without rotation or translation of the needle body. In our design, the structural integrity of the needle's steel tubing was preserved for mechanical robustness. Probing the optical signal was performed through the needle's own window formed at the end. For hand-held operation of our imaging needle, a light and compact scanner module (130 g and 45 × 53 × 60 mm3) was devised. Connected to the imaging needle, it could provide rotational actuation driven by a galvanometer. Because of its finite actuation range, our scanner module did not need a fiber rotary joint which might add undesirable complexity. The beam scan speed was 20 Hz and supported 20 frames per second at the maximum for endoscopic OCT imaging.

The Latest Trend of Dynamic MR Defecography for the Chronic Constipation Patient (만성 기능성 변비 환자에서 동적 MR Defecography의 최신동향)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.17-21
    • /
    • 2004
  • With advancement of the medical imaging technology, the dynamic pelvic MRI (magnetic resonance imaging) has been introduced and used for dynamic MR defecography to improved diagnosis of the patients. At the early stage of its use, it was mostly used to diagnose enterocele or cystocele, then its use was extended to diagnose the organ prolapse and other dysfunctional pelvis organs. There now have been many reports of other diseases such as the functional constipation and others. This paper introduces the pelvis MRI and the dynamic MR defecography and reports the future trend in their clinical applications. Until recently, the studies with pelvic MRI were mostly focused on observing the movement of the pelvis in the supine position. Yang and 26 others reported good result in observing the patients with the pelvic organ prolapse by using the pubococcygeal line as the anatomical index. Using the fast gradient recalled acquisition (fast GRASS), they compared cystocoele, genitourinary prolapse, enterocoele and rectocoele with the control group. Kruyt et al. observed the posterior compartment and reported that MRI was more helpful than the fluoroscopy. Healy et al. applied the dynamic MRI test on the patients with constipation or incontinence as well as the control group without those symptoms. Since then, MRI technology has further advance by Lienemann, who was able to attain the more detailed images using the fast T2 weighted turbo spin echo technology, and others. If its limitation in diagnosing intussusception and the like, since the observation can be made only from the supine position, can be overcome with open MR or others, it is envisages that the method can eventually replace the radiological defecography.

  • PDF

Optical System Design and Image Processing for Hyperspectral Imaging Systems (초분광 분해기의 광학계 설계 및 영상 처리)

  • Heo, A-Young;Choi, Seung-Won;Lee, Jae-Hoon;Kim, Tae-Hyeong;Park, Dong-Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.328-335
    • /
    • 2010
  • A hyperspectral imaging spectrometer has shown significant advantages in performance over other existing ones for remote sensing applications. It can collect hundreds of narrow, adjacent spectral bands for each image, which provides a wealth of information on unique spectral characteristics of objects. We have developed a compact hyperspectral imaging system that successively shows high spatial and spectral resolutions and fast data processing performance. In this paper, we present an overview of the hyperspectral imaging system including the strucure of geometrical optics and several image processing schemes such as wavelength calibration and noise reduction for image data on Visible and Near-Infrared(VNIR) and Shortwave-Infrared(SWIR) band.