• Title/Summary/Keyword: FA test

Search Result 251, Processing Time 0.024 seconds

Evaluation of Shrinkage of Heavyweight Magnetite Concrete with Fly Ash (플라이 애쉬 치환율에 따른 중량 자철석 콘크리트의 건조수축 평가)

  • Mun, Jae-Sung;Yang, Keun-Hyeok;Lee, Hyun-Ho;Kim, Sang-Chel
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.152-157
    • /
    • 2014
  • The objective of this study is to examine the drying shinkage and autogenuous shrinkage strains of heavyweight magnetite concrete. As a main parameters, cement was partially replaced by fly ash (FA) from 5% to 35%. The measured shrinkage strains were compared with predictions obtained from CEB-FIP equations and Yang et al.'s model. Test results showed that the magnitite of the autogenous and total shrinkage strains of heavyweight concrete slightly increased as the amount of fly ash increases up to 15%, beyond which the strains tended to decrease. The CEB-FIP equations considerably underestimated the shrinkage behavior of heavyweight concrete, indicating that this trend was more notable with the age. On the other hand, Yang et al.'s model predicted accurately the shrinkage of heavyweight concrete.

Processing and Quality of Natural-tasting Steamed Fish Paste Containing Unwashed Pufferfish Lagocephalus wheeleri Surimi (복어(Lagocephalus wheeleri) 수리미를 첨가한 어묵의 제조 및 품질특성)

  • Ahn, Byeong-Soo;Kim, Byeong-Gyun;Hwang, Seok-Min;Park, No-Hyun;Lee, Hyun-Jin;Oh, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.562-570
    • /
    • 2019
  • To develop natural-tasting fish paste from the pufferfish Lagocephalus wheeleri, steamed pufferfish paste (SPP) was prepared and its optimal processing conditions, quality metrics, and shelf-life characteristics were examined. SPP was produced by thawing golden threadfin Nemipterus virgatus surimi (FA grade), then adding 10% unwashed pufferfish surimi (PS), 1.5% salt, 8.0% wheat starch, 0.25% calcium carbonate, 0.25% sugar, 0.75% sorbitol, 0.25% polyphosphate, and 12.0% pufferfish hot-water extract (Brix 10°). The meat was ground with a Stephan mixer, molded at low temperature (18℃, 10 h), vacuum packed in a laminated plastic film bag, heat treated with hot water (95℃, 50 min), and cooled. As the amount of PS added increased, the whiteness, gel strength, and shear strength of the SPP decreased slightly. However, the SPP folding test showed no deterioration in the texture. In the sensory evaluation, the SPP received a higher rating for taste, smell, and overall taste than commercial Japanese pufferfish Kamaboko. The total amino acid content of the SPP was 10,262.6 mg/100 g; the major amino acids were aspartic acid, glutamic acid, alanine, valine, leucine, lysine, and arginine. The free amino acid content was 133.0 mg/100 g; the major amino acids were taurine, glutamic acid, glycine, alanine, cystine, and lysine.

Cell adaptation of KPEDV-9 and serological survey on porcine epidemic diarrhea virus(PEDV) infection in Korea (돼지 유행성설사바이러스 국내 분리주(KPED-9) 의 세포증식성 및 혈청학적 역학조사)

  • Kweon, Chang-hee;Kwon, Byung-joon;Kang, Yung-bai;An, Soo-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.2
    • /
    • pp.321-326
    • /
    • 1994
  • Korean isolate, porcine epidemic diarrhea virus (KPEDV-9) was adapted through serial passages in vero cell. The viral yield reached up to $10^{5-6}$ $TCID_{50}/ml$ at the passage level of 90th. The cell adapted virus was characterized through genetic and morphological examinations. The RNA extracted from virus infected cell revealed the presence of RNA band with molecular size of >20Kb. The electron microscopic examination on purified virus showed the pleomorphic appearance of enveloped particles with 5-10nm surface projections, which fit with the shape of coronavirus. The etiological survey on swine diarrhea by immunofluorescence test(FA) indicated 17.5% positive rate on the PEDV infection. In addition, the incidence were detected both in piglets within two weeks old as well as fattening pigs. Serological survey by ELISA revealed the overall 45% positive result, thus, indicating the PEDV infection are widespread throughout this country.

  • PDF

A Case Study on Field Construction of Cold Weather Mass Concreting Using Double Bubble Sheets and Hydration Heat Difference Method (이중 버블시트 및 수화발열량차 공법에 의한 한중매스콘크리트의 현장적용 연구)

  • Kim Jong;Yoon Jae-Ryung;Jeon Chung-Keun;Shin Dong-An;Oh Seon-Gyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.15-18
    • /
    • 2006
  • The test result of mat concrete applying both hydration heat difference and insulation curing method on new construction of Cheongju university educational building are summarized as following. Both fresh concrete and compressive strength properties were satisfied In aimed value. Setting time of concrete incorporating 15% of fly ash(FA) retarded 1.2 hour than control concrete. Temperature history of mali concrete indicated that the highest temperature of center was exhibited at $126^{\circ}C$ after 51 hours while the highest temperature of upper section was $10.6^{\circ}C$ after 46 hours. Temperature Difference between center and surface was managed at less than $6^{\circ}C$ during whole curing period. In addition the temperature of upper section secured more than $3.3^{\circ}C$ while the temperature of outside was indicated at less than $-10^{\circ}C$. Maturity by parts of construction secured more than $30^{\circ}C$ DD higher than outside at 3 days. The more number of times, applying insulation curing method by double bubble sheets, increased, the higher economic effect was secured. Overall it was clear that applying both double bubble sheets and hydration heat difference method on this new construction can resist hydration heat crack, early frost demage and strength decrease. It also significantly contributed quality improvement of cold weather concreting

  • PDF

Protective effects of IgY against diarrhea in suckling piglets -I. Serological result, FA test and RT-PCR- (IgY 투여에 따른 포유자돈의 설사에 대한 예방효과 -I. 혈청학적 결과, 형광항체검사 및 RT-PCT 검사-)

  • Jin, Wen;Yoon, Byung-Il;Han, Jeong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.1
    • /
    • pp.101-111
    • /
    • 2008
  • The purpose of this study was to investigate the protective effects against porcine epidemic diarrhea virus (PEDV) and transmissible gastroenteritis virus (TGEV) in suckling piglets by oral administration of IgY. Twenty piglets were divided into two groups with the same number: group I (treated with IgY) and group II (not treated). Group I was administerd orally with IgY for three days from one-day-old and experimentally challenged with PEDV and TGEV at four-day-old. The other was administered with saline solution and challenged with PEDV and TGEV at four-day-old. Serum antibody titers against PEDV and TGEV were examined by enzyme-linked immunosorbent assay (ELISA) and the detection of PEDV or TGEV antigen from feces and small intestines was performed by reverse transcription-polymerase chain reaction (RT-PCR) and indirect immunofluorescence (IFA). The antibody titers of the group I was higher than that of the other, and lasted at the end of experiment. In the detection tests of both virus from feces and small intestine, the rate of the group I was lower. Based on these results, oral administration of IgY may be effective to prevent the diarrhea caused by PEDV and TGEV.

Analysis Technique for Chloride Penetration in High Performance Concrete Behavior Considering Time-Dependent Accelerated Chloride Diffusivity (촉진염화물 확산계수의 시간의존성을 고려한 고성능 콘크리트의 염화물 침투 해석기법)

  • Kwon, Seung-Jun;Park, Sun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.145-153
    • /
    • 2013
  • Recently, accelerated chloride diffusion coefficients are used for an evaluation of chloride behavior. Similar as apparent diffusion coefficients, accelerated diffusion coefficients decrease with time. In this study, decrease in diffusion coefficient with time is simulated with porosity. Utilizing DUCOM-program, porosities from 15 mix proportions are obtained and diffusion coefficients are modelled with regression analysis of porosity for 270 days. Considering non-linear binding capacity which means the relation between free and bound chloride ion, chloride behavior in high performance concrete is evaluated. Through utilizing the previous test results for concrete under chlorides for 180 days, the applicability of the proposed technique is verified. The proposed technique is evaluated to reasonably predict the chloride behavior in concrete with various w/c (water to cement) ratios and mineral admixtures (GGBFS and FA). It is also shown that decrease in chloride diffusion should be considered for chloride prediction in concrete with mineral admixture since it has very clear decrease in diffusivity with time.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

FPGA Implementation of VME System Controller (VME 시스템 제어기의 FPGA 구현)

  • Bae, Sang-Hyun;Lee, Kang-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2914-2922
    • /
    • 1997
  • For FA (factory automation) and ATE (automatic test equipment) in the industrial area, the standard bus needs to increase the system performance of multiprocessor environment. VME(versa module european package format) bus is appropriated to the standard bus but has features of small package and low board density. Beside, the density of board and semiconductor have grown to become significant issues that affect development time, project cost and field diagnostics. To fit this trend, in this paper, we composed Revision C.1 (IEEE std. P1014-1987) of the integrated environment for the main function such as arbitration, interrupt and interface between, VMEbus and several control modules Also the designed, VME system controller is implemented on FPGA that can be located even into slot 1. The control and function modules are coded with VHDL mid-fixed description method and then those operations are verified by simulation. As a result of experiment, we confirmed the most important that is the operation of Bus timer about Bus error signal should occur within $56{\mu}m$, and both control and function modules have the reciprocal operation correctly. Thus, the constructed VHDL library will be able to apply the system based VMEbus and ASIC design.

  • PDF

Effects of Environmental Factors on Nitrite Accumulation in a Strong Nitrogen Removal System (고농도 질소폐수 처리 공정에서 환경인자가 아질산염 축적에 미치는 영향)

  • Park, Noh-Back;Choi, Woo-Yung;Yoon, Ae-Hwa;Jun, Hang-Bae;Park, Sang-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.51-62
    • /
    • 2010
  • The high concentration of N in the wastewater from livestock farming generally renders the efficiency of the wastewater treatment. Therefore, removal of N in livestock wastewater is crucial for successful treatment. The current study was conducted to investigate the optimum conditions for partial nitrification under anaerobic condition following nitritation in TPAD-BNR(two-phase anaerobic digestion-biological nitrogen removal) operating system. Sequential operating test to stimulate partial nitrification in reactor showed that partial nitrification occurred at a ratio of 1.24 in $NO_2{^-}$-N:$NH_4{^+}$-N. With this result, a wide range of factors affecting stable nitritation were examined through regression analysis. In the livestock wastewater treatment procedure, the hydraulic retention time (HRT) and pH range for optimum nitrite accumulation in the reactor were 1-1.5 days and 7-8, respectively. It was appeared that accumulation of $NO_2{^-}$-N in the reactor is due to inhibition of the $NO_2{^-}$-N oxidizer by free ammonia (FA) while the effect of free nitrous acid was minimal. Nitrification was not influenced by DO concentration at a range of 2.0-3.0 mg/L and the difference in the growth rate between $NH_4{^+}$-N oxidizer and $NO_2{^-}$-N oxidizer was dependent on the temperature in the reactor.

A Design of the Smart Control System for Industrial Automation Equipment (산업용 자동화 장비를 위한 스마트 제어 시스템 설계)

  • Kim, Bo-Hun;Kim, Hwang-Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.677-684
    • /
    • 2017
  • Smart devices are used in a variety of industries, because applications for them are easy to develop and portable. However, industrial equipment can cause security problems for information and accidents when controlling the actuator of the equipment at a remote location. In this paper, we studied methods of solving these problems and the advantages of applying smart control systems to industrial equipment. We propose a manual manipulation method using queries and a smart control access procedure for controlling equipment using a smart device. In addition, we propose a data transmission method employing multiple encryption protocols and a user authentication method using unique information from the smart device and Q & A as the communication data protection and user authentication methods, respectively. In order to evaluate its performance, an operation test of the smart control system and user authentication comparison experiment were performed. In order to understand the advantages of applying the smart control system to the equipment, we conducted a comparative experiment with a teach pendant and evaluated its reaction time in case of error.