• Title/Summary/Keyword: F0 Range

Search Result 1,444, Processing Time 0.03 seconds

F0 Extrema Timing of HL and LH in North Kyungsang Korean: Evidence from a Mimicry Task

  • Kim, Jung-Sun
    • 말소리와 음성과학
    • /
    • 제4권3호
    • /
    • pp.43-49
    • /
    • 2012
  • This paper describes the categorical effects of pitch accent contrasts in a mimicry task. It focuses, specifically, on examining how fundamental frequency (f0) variation reflects phonological contrasts from speakers of two distinct varieties of Korean (i.e., North Kyungsang and South Cholla). The results showed that, in a mimicry task using synthetic speech continua, there was a categorical effect in f0 peak timing for North Kyungsang speakers, but the timing of f0 peaks and valleys in the responses of South Cholla speakers was more variable, presenting a gradient or non-categorical effect. Evidence of categorical effects was represented as the shift of f0 peak times along an acoustic continuum for North Kyungsang speakers. The range for the shift of f0 valley times was much narrower, compared to that of f0 peak times. The degree of a shift near the middle of the continuum showed variability across individual mimicry responses. However, the categorical structure in mimicry responses regarding the clustering of f0 peak points was more significant for North Kyungsang speakers than for South Cholla speakers. Additionally, the finding of the current study implies that the location of f0 peak times depends on individuals' imitative (or cognitive) abilities.

저 압력 측정을 위한 실리콘 용량형 압력센서 (Silicon Capacitive Pressure Sensor for Low Pressure Measurements)

  • 서희돈;이윤희;박종대;최세곤
    • 센서학회지
    • /
    • 제2권1호
    • /
    • pp.19-27
    • /
    • 1993
  • 본 논문은 $n^{+}$ 에피택셜층을 이용한 전기화학 에칭스톱과 글라스-실리콘의 양극 접합기술을 이용하여 저 압력측정을 위한 용량형 압력센서를 제작한 것이다. 제작된 센서는 하이브리드형으로 센서 커패시터와 기준 커패시터를 갖는 센서 칩과 두가지 출력검출회로 칩으로 구성되어 있다. 이 제작된 센서는 다이아프램 크기가 $1.0{\times}1.0 mm^{2}$이고, 두께가 $10{\mu}m$로 제작된 센서는 압력이 인가되지 않을 때 용량의 크기가 7.1 pF이고, 10 KPa 압력에서 감도가 5.2 %F.S.이다. 또 용량을 전압으로 검출하는 컨버터회로를 이용할 경우, $5{\sim}45^{\circ}C$ 온도범위에서 영점 온도특성과 감도 온도특성은 각각 0.051 %F.S./$^{\circ}C$와 0.12 %F.S./$^{\circ}C$ 이다.

  • PDF

전자군 방법에 의한 C3F8분자가스의 비탄성충돌단면적의 결정 (Determination of an Inelastic Collision Cross Sections for C3F8 Molecule by Electron Swarm Method)

  • 전병훈
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.301-306
    • /
    • 2006
  • The electron drift velocity W and the product of the longitudinal diffusion coefficient and the gas number density $ND_{L}$ in the $0.525\;\%$ and $5.05\;\%$ $C_{3}F_8-Ar$ mixtures were measured by using the double shutter drift tube with variable drift distance over the E/N range from 0.03 to 100 Td and gas pressure range from 1 to 915 torr. And we determined the electron collision cross sections set for the $C_{3}F_8$ molecule by STEP 1 of electron swarm method using a multi-term Boltzmann equation analysis. Our special attention in the present study was focused upon the vibrational excitation and new excitations cross sections of the $C_{3}F_8$ molecule.

Assessment of genetic diversity and phylogenetic relationship of Limousin herds in Hungary using microsatellite markers

  • Szucs, Marton;Szabo, Ferenc;Ban, Beata;Jozsa, Csilla;Rozsa, Laszlo;Zsolnai, Attila;Anton, Istvan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권2호
    • /
    • pp.176-182
    • /
    • 2019
  • Objective: This study was conducted to investigate basic information on genetic structure and characteristics of Limousin population in Hungary. Obtained results will be taken into consideration when adopting the new breeding strategy by the Association of Hungarian Limousin and Blonde d'Aquitaine Breeders (AHLBB). Methods: Genetic diversity and phylogenetic relationship of 3,443 Limousin cattle from 16 different herds were investigated by performing genotyping using 18 microsatellite markers. Amplified DNA was genotyped using an automated genetic analyzer. Results: Mean of effective alleles ($n_e$) of the populations was 3.77. Population C had the lowest number of effective alleles (3.01) and the lowest inbreeding coefficient ($F_{IS}$) value (-0.15). Principal component analysis of estimated genetic distance ($F_{ST}$) values (p<0.000) revealed two herds (C and E) distinct from the majority of other Limousin herds. The pairwise $F_{ST}$ values of population C compared to the others (0.066 to 0.120) fell into the range of moderate genetic distance: 0.050 to 0.150, while population E displayed also moderate genetic distance ($F_{ST}$ values in range 0.052 to 0.064) but only to six populations (G, H, J, L, N, and P). $F_{ST(C-E)}$ was 0.148, all other pairs -excluding C and E herds- displayed low genetic distance ($F_{ST}$<0.049). Population D, F, I, J, K, L, N, O, and P carried private alleles, which alleles belonged to 1.1% of the individuals. Most probable number of clusters (K) were 2 and 7 determined by Structure and BAPS software. Conclusion: This study showed useful genetic diversity and phylogenetic relationship data that can be utilized for the development of a new breeding strategy by AHLBB. The results presented could also contribute to the proper selection of animals for further whole genome scan studies of Limousins.

Estimation of Mass Discrimination Factor for a Wide Range of m/z by Argon Artificial Isotope Mixtures and NF3 Gas

  • Min, Deullae;Lee, Jin Bok;Lee, Christopher;Lee, Dong Soo;Kim, Jin Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2403-2409
    • /
    • 2014
  • Absolute isotope ratio is a critical constituent in determination of atomic weight. To measure the absolute isotope ratio using a mass spectrometer, mass discrimination factor, $f_{MD}$, is needed to convert measured isotope ratio to real isotope ratio of gas molecules. If the $f_{MD}$ could be predicted, absolute isotope ratio of a chemical species would be measureable in absence of its enriched isotope pure materials or isotope references. This work employed gravimetrically prepared isotope mixtures of argon (Ar) to obtain $f_{MD}$ at m/z of 40 in the magnetic sector type gas mass spectrometer (gas/MS). Besides, we compare the nitrogen isotope ratio of nitrogen trifluoride ($NF_3$) with that of nitrogen molecule ($N_2$) decomposed from the same $NF_3$ thermally in order to identify the difference of $f_{MD}$ values in extensive m/z region from 28 to 71. Our result shows that $f_{MD}$ at m/z 40 was $-0.044%{\pm}0.017%$ (k = 1) from measurement of Ar artificial isotope mixtures. The $f_{MD}$ difference in the range of m/z from 28 to 71 is observed $-0.12%{\pm}0.14%$ from $NF_3$ and $N_2$. From combination of this work and reported $f_{MD}$ values by another team, IRMM, if $f_{MD}$ of $-0.16%{\pm}0.14%$ is applied to isotope ratio measurement from $N_2$ to $SF_6$, we can determine absolute isotope ratio within relative uncertainty of 0.2 %.

Ultrasonic Velocity and Absorption Measurements for Polyacrylamide and Water Solutions

  • Bae, Jong-Rim;Kim, Jeong-Koo;Yi, Meyung-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • 제22권4E호
    • /
    • pp.155-160
    • /
    • 2003
  • Both ultrasonic velocity at 3 MHz and absorption coefficient for the frequency range of 0.2-2 MHz were measured in an aqueous solution of polyacrylamide for the concentration range of 0.5% to 2.5% by weight. Pulse echo overlap method was taken for measuring the ultrasonic velocity over the temperature range of 10-90℃ and the high-Q ultrasonic resonator method was used for the absorption coefficient at 30℃. The velocity exhibited a maximum value at approximately 70℃, 71℃, 72℃, 73℃ and 74℃ in 2.5%, 2.0%, 1.5%, 1.0%, and 0.5% solutions, respectively. The velocity increased with the concentration at a given temperature. The ultrasonic absorption (a/f²) at a given temperature increased linearly with the concentration for the concentration below 1.5%, but suddenly increased for the concentration above 1.5% concentration. The value of a/f² at 1MHz was entirely due to the classical Stoke's viscous effect. The ultrasonic relaxation in polyacrylamide aqueous solutions, which may be the result of structural fluctuations of polymer molecules such as the segmental motion of the polymer chains, was observed, and at 2.5%, the value of a/f² was found to suddenly increase as frequency decreased.

A study on F8L10D-N LoRa RF Module for Drone Based live Broadcasting system

  • Mfitumukiza, Joseph;Mariappan, Vinayagam;Lee, Minwoo;Cho, Juphil;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • 제4권4호
    • /
    • pp.1-5
    • /
    • 2016
  • In this paper, we present the study on the proposed design of a real-time transmission of a video from the drone to broadcasting station (OBVan) by using F8L10D-N LoRa Module. Nowadays, LoRa technology is proved to be the mass of low cost, long range machine-to-machine connectivity. Particularly in the field of broadcasting and communication system, F8L10D-N LoRa RF Module spread spectrum technology with long transmission distance and strong penetrative ability that is double stronger than traditional FSK as well as PSK modulation scheme.

주기적으로 회전진동하는 원주 후류의 공진특성 (Lock-on Characteristics of wake behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.18-21
    • /
    • 2004
  • Lock-on characteristics of the flow around a circular cylinder performing a rotationally oscillation with a relatively high forcing frequency have been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), amplitude of oscillation $(\theta_A)$, and frequency ratio $F_R=f_f\;/\;f_n$, where $f_f$ is the forcing frequency and if is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14\times10^3,\;\pi/15\leq\theta_A\leq\pi/3$, and $F_R=1.0$. The effects of this active control technique on the lock-on flow regime of the cylinder wake were evaluated through wake velocity measurements and spectral analysis of hot-wire signals. The rotary oscillation modified the flow structure of near wake significantly. The lock-on phenomenon was found to occur in the range of frequency encompassing the natural vortex shedding frequency. In addition, when the amplitude of oscillation is less than a certain value, the lock-on phenomenon was occurred only at $F_R=1.0$. The lock-on range expanded and vortex formation length decreased as the amplitude of oscillation increases. The rotary oscillation generated small-scale vortex structure just near the cylinder surface.

  • PDF

경미한 경부 증상이 있는 대상자의 경추 관절 운동 범위 연구 (Cervical Range of Motion Associations with Sub-clinical Neck Pain)

  • 이해정
    • PNF and Movement
    • /
    • 제1권1호
    • /
    • pp.43-57
    • /
    • 2003
  • 목적: 병원치료가 필요하지 않을 만큼의 경부통증/증상과 관절가동범위, 경흉추의 다각적 면에서 관계를 조사하기 위해서이다. 방법: 연령은 19세에서 42세(평균연령 28세로 실험에 참여하기를 원하는 건강한 성인 40명을 대상으로 하였다. 경흉추의 척추 자세, 경추 능동 관절 가동범위, 경부 분절 길이 등의 다각적인 면을 측정하였다. 모든 측정들은 동일시에 각 대상자에게 서로 다른 측정자에 의해 두 번 실시되었다. 경부 근 지구력은 수정된 Biering-Sorensen 검사법에 의해 측정되었다. 마지막으로 대상자들에게 경부 통증/증상의 재발에 대한 질문을 하였다. 결과: 14명의 대상자들은 경미한 재발성 경부 통증/증상을 보고하였다. 경부 근 지구력 시간(F(1,38)=6.75, p=0.01)과 좌측 회전 가동 범위(F(1,38)=4.56, p=0.04)가 경부 통증을 가진 대상자들에서 유의하게 감소하였다. 신전 가동범위가 재 측정에서 특정군 변화 즉, 정상군 증가, 경부 통증/증상군 감소(F(1,38)=4.67, p=0.04)가 보였다. 경부 통증/증상군은 정상군과 비교 시 후인 가동 범위의 증가하였다(F(1,38) =4.56, p=0.04). 통증 유무에 관계없이 모든 대상자들에서 우측 회전보다 좌측 회전에서 가동범위가 더 크게 나타났고(F(1,38) =4.34, p=0.04), 반복 측정에서 좌측 측방굴곡 (F(1,38) =5.10, p=0.03)과 우측 측방 굴곡(F(1,38) = 5.27, p=0.03)의 감소가 나타났다. 결론: 경미한 증상의 경부통증 대상자군과 정상적인 대상자군을 비교할 때 그룹 간 차이는 경부 근 지구력 시간의 감소, 좌측 회전 가동 범위 감소와 특히, 두 번 째 측정에서 신전범위 감소가 나타났으나 후인의 가동범위는 증가로 관찰되었다. 이러한 결과들은 경부 통증의 발생과 관련된 초기 가동범위 변화를 제안한다.

  • PDF

$CaF_{2}$를 이용한 고체전해질 산소센서의 제조및 그 특성 (Fabrication of Solid Electrolyte Oxygen Sensors Using $CaF_{2}$ and their Characteristics)

  • 이재현;이덕동
    • 센서학회지
    • /
    • 제3권2호
    • /
    • pp.40-49
    • /
    • 1994
  • $CaF_{2}$ 불화물 고체전해질을 모물질로하는 저온동작용($300^{\circ}C{\sim}$500^{\circ}C) 산소센서를 제조하였다. $CaF_{2}$ 산소센서는 수축률과 SEM사진의 결과를 토대로 $850^{\circ}C$-3hr 동안 열처리 하였다. 디스크형 산소 센서는 기준전극으로 Air($O_{2}:21%$)|Pt를, 전해질로는 $CaF_{2}$, 감지전극으로 Pt를 사용하였으며, 기준전극 내장형 산소센서는 기준전극으로 NiO/Ni (30:70)을 사용하였다. 디스크형 산소센서의 경우 측정온도 $400^{\circ}C$에서 산소농도($0.1 %{\sim}10%$)로 변화시 45mV 정도의 기전력 변화를 보였으며, 기준전극 내장형의 경우는 40mV의 변화를 보였다.

  • PDF