• Title/Summary/Keyword: Eye point

Search Result 340, Processing Time 0.028 seconds

Scanning Determination & Observation Features by Sex shown in the Process of Acquiring Visual Information - With the Object of Subway Station Hall Space - (시각정보획득과정에 나타난 주사판정과 성별 주시특성 - 지하철 홀 공간을 대상으로 -)

  • Kim, Jong-Ha;Choi, Gae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.6
    • /
    • pp.115-124
    • /
    • 2014
  • This study has carried out scanning tests in order to figure out the features of scanning search by sex of space users, with the result of which the validity of data has been estimated. In this research, the scanning patterns were set up for verifying the typology of scanning paths and then the reason for determining scanning paths and the validity of estimation method were reviewed. Since the observation features depends on sex, the analysis of visual activities for acquiring any information in a space will reveal the intention and purpose of space users. The findings by analyzing the features of scanning pattern by sex which were found at the determination of scanning patterns can be defined as the followings. First, for estimating the process of space-information search, the movement distance at each point of continuative-observation data from the angle of eye-movement has been extracted, on the ground of which the fixation and movement of eye have been defined for the establishment of scanning-cut characteristics. Second, the scanning times were estimated for the extraction of effective observation data that would be used for comparative analysis, which showed that men had more data (3,398.2/64.4%) than women (2,998.2/55.6%). This enables the acknowledgment that the scanning cut of men was relatively less, which indicates that men will acquire more information on space than women in the process of observing any space. Third, men's scanning times (58.0 times/2.02 seconds) were less than those of women (71.9 times/1.39 seconds) while the scanning time of the former was longer than that of the latter, which shows the feature that it takes longer for men than women in scanning while the scanning times of the former is less than those of the latter. Fourth, the observation features can be determined that the combination of this result with the predominance character by sex for a general viewpoint to be employed indicates that while men employ mixed-scanning for observation activities to acquire space-information spending for longer time, women, by concentrated-scanning, focus on a single point for shorter time or stay at one location for a considerably long time for space-information acquirement.

Clinical validation of ImmuneCheck IgE for the rapid detection of serum total IgE (총 IgE의 신속한 정량 측정을 위한 ImmuneCheck IgE의 임상적 유용성)

  • Lee, Shinhaeng;Choi, Jinyoung;Choe, Eunju;Lee, Sang Chul;Park, Kyung Hee;Lee, Jae-Hyun;Park, Jung-Won
    • Allergy, Asthma & Respiratory Disease
    • /
    • v.6 no.6
    • /
    • pp.310-314
    • /
    • 2018
  • Purpose: Conventional serum IgE assay was costly, required the skills of expert, and relied heavily on expensive equipment. Quantitative measurement of total IgE using Point of Care Test (POCT) device can be the solution for these limitations. This study evaluated and validated the reproducibility of ImmuneCheck IgE. Methods: This study included 120 patients of allergic diseases such as allergic rhinitis, asthma, drug allergy, food allergy, atopic dermatitis, or anaphylaxis. The reliability of POCT ImmuneCheck IgE was evaluated by comparing results from the naked eye and from the Q-Reader. Intratest reproducibility and intertest correlation were analyzed using intraclass correlation coefficient (ICC). Results: Of the 120 enrolled patients, 51 were males and 69 were females. The ages ranged from 19 to 84 years, with an average age of 51.5 years. The concentration of serum total IgE measured by Phadia ImmunoCAP IgE ranged from 5.95 to 5,000 IU/mL. ICC for Intratest reproducibility of ImmuneCheck IgE by naked eye and by Q-Reader were 0.991 (P< 0.001) and 0.989 (P< 0.001), respectively. In addition, intertest correlation between ImmuneCheck IgE and Phadia ImmunoCAP IgE results of naked eye and Q-Reader were 0.968 (P< 0.001) and 0.948 (P< 0.001), respectively. Conclusion: The ImmuneCheck IgE was reproducible and highly correlated with conventional Phadia ImmunoCAP IgE assay. This result suggests that ImmuneCheck IgE can be a useful tool for rapid and precise detection of total IgE.

A Feature Point Tracking Method By Using Template Matching and Buffer (템플릿 매칭과 버퍼를 이용한 특징점 추적 방법)

  • Cho, Jeong-Hyun;Ahn, Cheol-Woong;Jun, Jae-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.173-179
    • /
    • 2014
  • Today, a surgery for cataract of Korean society frequently come to operation. A method for treating cataracts have been developed in various ways. Widely used method is a method to use the artificial lens and replace it with the existing lens. The surgery can be inserted exactly according to the angle and points that are calculated in advance in the intraocular lens insertion is important. However, The lens insertion point can delete or blur the display due to such factors as foreign material coming out of the eye during surgery. Therefore, The lens insertion point needs a method of tracking the image processing by receiving the camera images in real time display method. In this paper, we propose a feature point tracking method by using template matching and buffer. a simulation results show that our ideas can track a feature point of the intraocular lens insertion.

A Study on the Pattern Development and Wear Fitness of the Bodysuit (Bodysuit의 패턴개발과 적합성에 관한 연구)

  • 최미성
    • Korean Journal of Rural Living Science
    • /
    • v.5 no.2
    • /
    • pp.93-106
    • /
    • 1994
  • The purpose of this study was to develop the pattern of bodysuit and to identify the wear fitness of it The methods of statistical analysis applied to the study were ANOVA and cluster analysis. The materials used in making bodysuit were Nylon/Polyurethane, lace, power net, binding tape, and hook eye. The try-on test was administered in two aspects ; (1) the comparison of anthropometric data before and after trying on the experimentally constructed bodysuit with those of marketing bodysuit, (2) the sensory evaluation to estimate the wear fitness in terms of appearance and motion function. The conclusions obtained are as follows ; 1. In the survey of wearing state, 52.2% of respondents had experience of wearing bodysuit. 60.6% of them responded to the item, “well-balanced body” in the question about the purpose of wearing it. 55.7% considered the item, “feel choky in the chest” as uncomfortable point in putting on bodysuit. 48.3% felt the portion of crotch drawn above in taking exercise or behaving routinely in everyday life. 2. As for the characteristics of the bodysuit design, the scooped neckline and horizontal outline without wire in lower bust was used, the adjust point being located right above the perineum point, and the length of bodysuit is as far as trochanteric point. 3. In comparing anthropometric data of the subjects, there was significant difference in the height of lower bust the distance around abdomen, and the length of bust point(right, left) between the experimentally constructed bodysuit and the marketing bodysuit. 4. Concerning the results of the try-on test in appearance, the estimates of expert panel, which were in agreement with those of subjects in mean value and composite reliability coefficient, showed that the pattern fitness of experimentally designed bodysuit was higher than that of marketing bodysuit. 5. To take try-on test in motion function, motion was classified the five steps. The results of the test showed that experimentally designed bodysuit was fitter in each steps of motion than marketing bodysuit.

  • PDF

Development of dynamics simulation model for 3-point hitch of agricultural tractor during plow tillage

  • Mo A Son;Seung Yun Baek;Seung Min Baek;Hyeon Ho Jeon;Ryu Gap Lim;Yong Joo Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.937-948
    • /
    • 2022
  • Agricultural operations are performed in uneven environments by attaching an implement on the 3-point hitch of a tractor. A high load is thus placed on the 3-point hitch, and fatigue and failure of the hitch may occur during agricultural operations. In this study, a dynamic simulation model was developed to predict the load occurring on the eyebolt of a 3-point hitch, which is the main damaged component. The simulation model was developed and validated using agricultural data as simulation input and validation data. The dynamics model was developed using the specifications of a 78 kW class tractor. A measurement system was constructed to measure the simulation input and validation data. The simulation model was validated using a traction load on an eye bolt, which was measured during plow tillage operation. The measurement results showed that the average traction load on the left and right lower link and the top link were 8,099.97, 4,943.06, and 636.11 N, respectively. The simulation results and the measured traction load on the left eyebolt were respectively 610.30 and 597.15 N. The simulation results and measured traction load on the left eyebolt were respectively 1,179.78, and 1,145.06 N. The error between the simulation and measurement data was roughly 2% on the left eyebolt and 3% on the right eyebolt.

3D Physical User Interface System using a Dominant Eye and an Index Fingertip (주시안과 검지 끝 점을 이용한 3차원 물리 사용자 인터페이스 시스템)

  • Kim, Kyung-Ho;Ahn, Jeeyun;Lee, Jongbae;Kwon, Heeyong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.2
    • /
    • pp.138-146
    • /
    • 2013
  • In this paper, we propose a new 3D PUI(Physical User Interface) system in which the index fingertip points and moves a mouse position on a given monitor screen. There are two 3D PUI schemes to control smart devices like smart TVs remotely, the relative pointing one and the absolute pointing one. The former has a problem in that it does not match the human perception process, and the latter requires excessive movement of the body. We combined the relative one and the absolute one, and develop a new intuitive and user-friendly pointing method, 3D PUI. It requires an establishment of a pyramid shape visible area (view volume) to point a mouse position on a screen with the dominant eye. In order to maintain the real-time view volume, however, it requires large computation depending on the movement of the dominant eye. We optimized the computation of the view volume in which it determines the internal and external position on the screen. In addition, Kalman filter is applied with tracing of the mouse pointer position to stabilize the trembling of the pointer and offers the user ease of use.

A Study on the Characteristics of Consumer Visual-Perceptional Information Acquisition in Commercial Facilities in Regard to its Construction of Space from Real-Time Eye Gaze Tracking (상업시설 공간구성의 실시간 시선추적에 나타난 소비자 시지각 정보획득 특성 연구)

  • Park, Sunmyung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.3-14
    • /
    • 2018
  • For satisfying consumer needs, commercial facilities require a variety of sale-related space expressions and eye-catching product arrangements; space composition can also be a direct marketing strategy. The human eye is the sensory organ that acquires the largest amount of information, and an analysis of visual information helps in understanding visual relations between . However, the existing studies are mostly focused on analysis of still frames in experimental images, and there is a lack of studies analyzing gaze information based on mobile images of commercial spaces. Therefore, this study analyzed emotional responses through gaze information of space users in reality using a video of a movement route through a commercial facility. The analysis targeted straight sections of the moving route; based on the data acquired, sectional characteristics of five gaze intensity ranges were examined. As a result, section A, the starting point of the route, had a low gaze intensity, while section B had the highest gaze intensity. This indicates that, starting in section B, the subjects explored the space in a stable way and needed time to adapt to the experimental video. In relation to space characteristics of the gaze-concentrated area, display formats of the right stores in 4 of 6 sections received greater attention. The gaze of consumers was mostly focused on props, and big gaze information was revealed in showcase display formats of the stores. In conclusion, this analysis method can provide highly useful direct design data about merchandise display and merchandise component arrangement based on consumer visual preference.

Effects of Proprioceptive Neuromuscular Facilitation Program Combined with Dynamic Neuromuscular Stabilization Approach on Balance in Patient with Cerebellum Atrophy -Case Report- (동적 신경근 안정화 접근법과 결합한 PNF 중재 프로그램이 소뇌 위축 환자의 균형에 미치는 영향 -사례보고-)

  • Na, Eun-Jin;Moon, Sang-Hyun;Kim, Eun-Kyung;Park, Du-Jin
    • PNF and Movement
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Purpose: This case report examines the influence of proprioceptive neuromuscular facilitation (PNF) combined with a dynamic neuromuscular stabilization approach on balance in patients with cerebellar atrophy. Methods: The target subject of this case report was a 34-year-old woman who was informed of the purpose of this research and voluntarily agreed to participate in it. The case report conformed to research ethics based on the Helsinki Declaration. The target subject was confirmed to have cerebellar atrophy from an unknown cause in 2009 and was diagnosed with slight ataxia. At that time, she could carry out daily activities without physical therapy. On May 19, 2015, she suffered both a subdural hemorrhage (SDH) and subarachnoid hemorrhage (SAH) in a traffic accident. She was urgently moved to the emergency room and managed by nonsurgical treatment, and then, the cerebellar atrophy and ataxia gradually deteriorated. To evaluate the patient's balance capacity before and after intervention, the trunk impairment scale (TIS), trunk impairment scale (OLST) during eye-closing/opening, timed up and go test (TUG), and visual analogue scale (VAS) were conducted. The PNF intervention program was executed for 30 min, four times a week, for three weeks. Results: The TIS and OLST during eye-closing/opening were improved by as much as a point, by 8.15 s and 6.21 s, respectively, after applying the PNF program. TUG and VAS decreased by 1.33 s and 3 points, respectively, after intervention. According to the result, the OLST during eye-closing/opening and VAS improved remarkably in comparison with those before intervention. Conclusion: As the final result of the case report, PNF intervention combined with DNSA more effectively improved the static balance capacity, such as the OLST during eye-closing/opening and VAS, compared to the dynamic balance capacity. In addition, the intervention duration and period of the exercise program are recommended to be more than 1 h a day for four weeks considering the learning ability of a patient with cerebellar atrophy.

A Study of Dermal and Ocular Exposure to Isocyanate-Based Paints in Crash Repair Workshops (차량수리업에서 사용하는 이소시안계 페인트에 의한 피부와 눈의 노출에 관한 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo;Tkaczuk, Michael
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.72-78
    • /
    • 2009
  • Exposure to HDI(hexamethylene di-isocyanate) commonly used in vehicle crash repair workshops remains a leading cause of occupational asthma. Although skin and eye contamination are considered as absorption routes, there are no occupational exposure standards for skin and ocular exposure. This is the reason why there are more empirical data should be provided. Therefore this study was to determine contamination levels of HDI on the skin, eyes, work surfaces, respirators and eye protectors. There was evidence of contamination on a variety of work surfaces, for example, door handles, bench top and spray gun, etc. A high proportion(47~80%) of skin wipe samples from neck, forehead, back hand, palm and wrist was positive for HDI contamination, even though spray time was relatively brief. The contamination levels from spraying inside spray booth were generally higher than outside booth due to poor work practices and inappropriate personal protective use like safety gloves. Apprentices had higher exposure levels than the qualified painters, likely due to lack of the recognition of safety and hygiene. The extent of contamination inside the PPE might provide an indication of the potential for respiratory & skin exposure and ocular exposure. Eye fluid samples from 4 out of 14 workers had the positive detection of HDI contamination, due to poor work practices like no or inappropriate eye protection. Considering the potential for dermal & ocular exposure to contribute to possible health symptoms including respiratory sensitization, the empirical data point to a need for improving work practices and appropriate PPE selection, use and maintenance.

Determination of Spatial Resolution to Improve GCP Chip Matching Performance for CAS-4 (농림위성용 GCP 칩 매칭 성능 향상을 위한 위성영상 공간해상도 결정)

  • Lee, YooJin;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1517-1526
    • /
    • 2021
  • With the recent global and domestic development of Earth observation satellites, the applications of satellite images have been widened. Research for improving the geometric accuracy of satellite images is being actively carried out. This paper studies the possibility of automated ground control point (GCP) generation for CAS-4 satellite, to be launched in 2025 with the capability of image acquisition at 5 m ground sampling distance (GSD). In particular, this paper focuses to check whether GCP chips with 25 cm GSD established for CAS-1 satellite images can be used for CAS-4 and to check whether optimalspatial resolution for matching between CAS-4 images and GCP chips can be determined to improve matching performance. Experiments were carried out using RapidEye images, which have similar GSD to CAS-4. Original satellite images were upsampled to make satellite images with smaller GSDs. At each GSD level, up-sampled satellite images were matched against GCP chips and precision sensor models were estimated. Results shows that the accuracy of sensor models were improved with images atsmaller GSD compared to the sensor model accuracy established with original images. At 1.25~1.67 m GSD, the accuracy of about 2.4 m was achieved. This finding lead that the possibility of automated GCP extraction and precision ortho-image generation for CAS-4 with improved accuracy.